International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TCS Temperature Monitoring System for 128 Points over Ethernet

TCS collects up to 128 temperature signals through a single HES gateway and passes them onto an Ethernet network. Sixteen-channel TCM modules accept thermocouples, RTDs, potentiometers, ohm and millivolt signals and are intrinsically safe.

Channels per TCM module
16
TCM modules per HES gateway
up to 8
Measurement points per gateway
up to 128
Input types
thermocouple, RTD, potentiometer, ohms, millivolts

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Temperature remains the most common process variable in industrial plants. When dozens or hundreds of measurement points must be read for control or supervision, running a separate cable to every sensor quickly becomes costly and difficult to engineer. The TCS (Temperature Concentrator System) gathers these signals into a small number of modules and forwards them onto the plant's general Ethernet network, where a monitoring or control system can pick them up.

The core of the system is the TCM concentrator module. Each module provides 16 channels, and every channel is configured separately for a thermocouple, resistance thermometer (RTD), potentiometer, resistance input in ohms or a millivolt input. The module reports measured values using the HART protocol. A single HES gateway can connect up to eight TCM modules, so one gateway carries as many as 128 temperature signals onto a high-speed Ethernet backbone.

The HES gateway uses a dedicated HART command for this device type, reading all 16 values from a module in one message in under a second. For communication with higher-level systems, the gateway supports the industrial protocols MODBUS/TCP and HART-IP. An embedded web server displays the measurement points in a standard browser without a separate application, which simplifies checking signals during commissioning and day-to-day operation.

The TCM module is intrinsically safe and approved for use in hazardous areas, so it can be mounted close to the process equipment where the sensors are located. The HES gateway is installed where the Ethernet connection is available, and digital HART data travels between the modules and the gateway.

Typical sectors include oil and gas production, refining, power generation and transmission, chemicals, semiconductor and microelectronics manufacturing, pharmaceuticals and biotechnology, pulp and paper, mining and metals, water treatment and wastewater, food processing and data centres. The system is configured for the number of points required, from a single 16-channel module up to eight modules on one gateway.

Technical specifications

Channels per TCM module16
TCM modules per HES gatewayup to 8
Measurement points per gatewayup to 128
Input typesthermocouple, RTD, potentiometer, ohms, millivolts
TCM output protocolHART
HES gateway protocolsMODBUS/TCP, HART-IP
Reading 16 module valuesunder 1 s, in one message
TCM explosion protectionintrinsically safe
Data displayembedded web server

Part numbers

Show all part numbers (3)

TCS, TCM, HES

Request a price and lead time

TCS Temperature Monitoring System for 128 Points over Ethernet. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many temperature points can one HES gateway handle?

Up to eight TCM modules with 16 channels each, which makes up to 128 points transmitted over Ethernet.

Which sensors does the TCM module accept?

Each channel is set up separately for a thermocouple, RTD, potentiometer, ohm input or millivolt input.

Can the TCM module be installed in a hazardous area?

Yes, the module is intrinsically safe and approved for use in hazardous areas.