TCA Thermocouple Alarm for ISA Thermocouples, 4-Wire, Single or Dual Trip

The TCA takes input from all standard ISA thermocouples and closes a contact when the value leaves a preset limit. Accuracy is within ±0.1% of span, in single and dual alarm models, with upscale burnout protection as standard.

Type
thermocouple alarm, 4-wire
Input
any standard ISA thermocouple
Accuracy
±0.1% of span
Repeatability
±0.1% of input span

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TCA accepts input from all standard ISA thermocouples. When the input value falls outside a fully adjustable preset limit, it gives a contact closure that can indicate a high and/or low condition through a bell, buzzer, light or other device. A bright LED on the front panel shows that an alarm condition has occurred.

Accuracy is within ±0.1% of span. Single and dual alarm models are offered, and the dual models allow two separate trip points per module, set as High/Low, High/High or Low/Low. On both, trip points are set with potentiometers on the front panel. The thermocouple type and span are specified at order, with spans that include 10 mV and 25 mV. The SPDT relay contacts let the user choose either normally open or normally closed operation; DPDT relays are optional.

Input, output and power input are isolated with no dc connections between them, in both ac and dc powered units. Burnout protection drives the output upscale on thermocouple burnout as standard. Trip points repeat within ±0.1% of input span, standard deadband is 1% of span, and alarm response is 50 milliseconds for a step change of 1% of span beyond the trip point. The ambient range is -18°C to +65°C with an effect of less than ±0.018%/°C, trip points adjust over 0% to 100% of span, zero adjusts within ±25% of the maximum range value, and weight is approximately 908 grams.

Power is 117, 220 or 240 Vac, 50/60Hz, ±10%, or 24 or 45 Vdc, ±10%, at 5 watts nominal. Options are adjustable deadband of 1-20%, available up to 100% (-AD), an alarm response delay of 1 to 30 seconds set at the factory (-AR), a burnout alarm (-BA), downscale open input drive (-DD), DPDT relays (-DPDT), process variable indication and RFI/EMI protection (-RF). Housings are a surface-mount version and a high-density plug-in card version for control rooms, plus a field-mount enclosure. Approvals: CSA general location and hazardous location Class I, Groups C and D.

Technical specifications

Typethermocouple alarm, 4-wire
Inputany standard ISA thermocouple
Accuracy±0.1% of span
Repeatability±0.1% of input span
Deadband1% of span, standard
Alarm response50 milliseconds for a 1% of span step
Burnout protectionupscale on burnout, standard
Isolationinput, output and power with no dc connections
Power117, 220 or 240 Vac 50/60Hz ±10%; 24 or 45 Vdc ±10%
Ambient range-18°C to +65°C
Trip point adjustment0% to 100% of span
Weightapproximately 908 grams

How it compares with similar models

ParameterTCA Thermocouple Alarm for ISA Thermocouples, 4-Wire, Single or Dual TripRBA-STD RTD (Resistance Bulb) Alarm, 4-Wire, Single or Dual TripMVA Millivolt Alarm, 4-Wire, Single or Dual TripDDA DIN-Style Current and Voltage Limit Alarm Trip, 1-5V Input
Typethermocouple alarm, 4-wireRTD alarm, 4-wiremillivolt alarm, 4-wirecurrent and voltage limit alarm trip
Inputany standard ISA thermocouple2-wire or 3-wire RTD—1-5V
Alarm response50 milliseconds for a 1% of span step50 milliseconds for a 1% of span step50 milliseconds for a 1% of span step50 milliseconds
Isolationinput, output and power with no dc connectionsinput, output and power with no dc connectionsinput, output and power with no dc connections500Vac, input to output to power
Power117, 220 or 240 Vac 50/60Hz ±10%; 24 or 45 Vdc ±10%117 Vac or 220 Vac, 50/60Hz; dc—4-wire, 24VDC
Trip point adjustment0% to 100% of span0% to 100% of span0% to 100% of span, multiturn potentiometers—

Request a price and lead time

TCA Thermocouple Alarm for ISA Thermocouples, 4-Wire, Single or Dual Trip. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which thermocouples connect to the TCA?

All standard ISA thermocouples, with type and span specified at order.

What happens if the thermocouple burns out?

Standard burnout protection drives the output upscale; -BA adds a burnout alarm and -DD gives downscale open input drive.

Which supply voltages are available?

117, 220 or 240 Vac 50/60Hz, or 24 or 45 Vdc, all ±10%.