FCA Field-Configurable Current or Voltage Alarm, Two Relays, 4-Wire

The FCA takes a current or voltage signal from a temperature, pressure, level or flow transmitter and gives two separately configurable contact closures. Trip points and deadband are set on front-panel pots, and failsafe operation is chosen in the field.

Type
current or voltage alarm, 4-wire
Input
current or voltage signal
Output
two separately configurable contact closures
Alarm combinations
High/Low, High/High, Low/Low

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

An analogue device such as a temperature, pressure, level or flow transmitter sends a current or voltage signal to the FCA. When the signal exceeds a preset limit, the alarm gives two separately configurable contact closures, which can drive a bell, buzzer, light or other device to indicate high and/or low process conditions. Front-panel LEDs show when the unit is in an alarm condition.

Each module carries two independent alarm trips from a single signal input, which cuts space requirements and equipment cost. The alarms can be set to any combination of High/Low, High/High or Low/Low. Trip point and deadband settings are made quickly with potentiometers on the front panel, one per relay, and the choice between failsafe and non-failsafe operation is made in the field. In failsafe units the LED goes off when an alarm trips; in non-failsafe units it comes on.

Trip points repeat within ±0.1% of input span. Deadband adjusts from 1 to 20% of span, and average input-to-output response time is 50 msec for a step input. A DIN-style universal mounting clip fits a 32mm G-type (EN50035) or 35mm Top Hat (EN50022) rail, in a control room or in a field-mounted cabinet.

Options include AR, an alarm response delay of 150 milliseconds to 30 seconds (units with this option need a 45 second warm-up after first power-on); DA, a deviation alarm that trips when the difference between two inputs exceeds a set limit, with the input specified at order as 2X1-5V, 2X4-20MA or 2X10-50MA; and MR, manual reset through terminals on the front panel, which removes the adjustable deadband.

Technical specifications

Typecurrent or voltage alarm, 4-wire
Inputcurrent or voltage signal
Outputtwo separately configurable contact closures
Alarm combinationsHigh/Low, High/High, Low/Low
Repeatability±0.1% of input span
Deadband1 to 20% of span
Response time50 msec average, input to output
Modefailsafe or non-failsafe, field-configurable
MountingDIN-style clip, 32mm G-type (EN50035) or 35mm Top Hat (EN50022) rail
OptionsAR, DA, MR

How it compares with similar models

ParameterFCA Field-Configurable Current or Voltage Alarm, Two Relays, 4-WireRBA-STD RTD (Resistance Bulb) Alarm, 4-Wire, Single or Dual TripTCA Thermocouple Alarm for ISA Thermocouples, 4-Wire, Single or Dual TripTMZ MODBUS converter for current and voltage signals, 0-50mA and 0-10V, 24DC
Typecurrent or voltage alarm, 4-wireRTD alarm, 4-wirethermocouple alarm, 4-wirePC-programmable MODBUS signal converter for current and voltage
Inputcurrent or voltage signal2-wire or 3-wire RTDany standard ISA thermocoupleProgrammable, any range within 0-50mA or 0-10V
Deadband1 to 20% of span1% of span, standard1% of span, standard—

Request a price and lead time

FCA Field-Configurable Current or Voltage Alarm, Two Relays, 4-Wire. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many alarms does one FCA have?

Two independent alarms from one input, configurable as High/Low, High/High or Low/Low.

Can an alarm delay be added?

Yes, the AR option sets a response delay from 150 milliseconds to 30 seconds, with a 45 second warm-up after first power-on.

Which rails does the FCA mount on?

On a 32mm G-type (EN50035) or 35mm Top Hat (EN50022) rail.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides