DDA DIN-Style Current and Voltage Limit Alarm Trip, 1-5V Input
The DDA accepts standard process current and voltage signals from transmitters and transducers and gives a contact closure when the input crosses a preset limit. The DDA/1-5V/SH1/24DC variant has one high-set failsafe alarm, a display and 24VDC power.
- Type
- current and voltage limit alarm trip
- Model
- DDA/1-5V/SH1/24DC [DIN]
- Input
- 1-5V
- Output
- single alarm, set as high, failsafe, contact closure
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Standard process current and voltage inputs from field transmitters and transducers go into the DDA. When the input value falls outside a fully adjustable preset limit, the unit closes a contact to indicate a high and/or low condition through a bell, buzzer, light or other device. A typical model is DDA/1-5V/SH1/24DC: 1-5V input, a single alarm set as high and failsafe, and 4-wire 24VDC power.
Single and dual alarm models are offered. The dual models allow two separate trip points per module, configured as High/Low, High/High or Low/Low. Trip points are set with multiturn potentiometers on the front panel, and the integral display shows the upper and lower settings as well as the input signal. High/Low selection is made with internal solderless jumpers. Front-panel LEDs show the alarm state; an LED that is on means the relay is energised.
The display shows the input in percentage as standard, or in engineering units with the -EU option. Other options include 2-wire transmitter excitation and adjustable deadband. Complete input, output and power isolation, together with built-in RFI/EMI protection, prevents false alarms in noisy environments.
Display accuracy is ±0.1% of input span ±1 count, and the trip point repeats within ±0.1% of input span. Standard deadband is 1% of input span, alarm response is 50 milliseconds, and isolation is 500Vac between input, output and power. The ambient range is -18°C to +65°C, and trip points adjust over -5% to 105% of span, typically. The DIN housing mounts on a 35mm Top Hat rail. Approvals: CSA general (ordinary) location, and CE conformance.
Technical specifications
| Type | current and voltage limit alarm trip |
|---|---|
| Model | DDA/1-5V/SH1/24DC [DIN] |
| Input | 1-5V |
| Output | single alarm, set as high, failsafe, contact closure |
| Power | 4-wire, 24VDC |
| Display | integral |
| Configuration | face-plate configurable |
| Display accuracy | ±0.1% of input span, ±1 count |
| Repeatability | ±0.1% of input span |
| Dead band | 1% of input span (standard) |
| Alarm response | 50 milliseconds |
| Isolation | 500Vac, input to output to power |
| Ambient range | -18°C to +65°C |
| Housing | DIN-style, 35mm Top Hat rail |
How it compares with similar models
| Parameter | DDA DIN-Style Current and Voltage Limit Alarm Trip, 1-5V Input | RBA-STD RTD (Resistance Bulb) Alarm, 4-Wire, Single or Dual Trip | TCA Thermocouple Alarm for ISA Thermocouples, 4-Wire, Single or Dual Trip | ECA DIN rail current and voltage limit alarm trip, two relays, 24DC supply |
|---|---|---|---|---|
| Type | current and voltage limit alarm trip | RTD alarm, 4-wire | thermocouple alarm, 4-wire | current and voltage limit alarm trip |
| Input | 1-5V | 2-wire or 3-wire RTD | any standard ISA thermocouple | 1-5VDC |
| Power | 4-wire, 24VDC | 117 Vac or 220 Vac, 50/60Hz; dc | 117, 220 or 240 Vac 50/60Hz ±10%; 24 or 45 Vdc ±10% | 24DC, 4-wire |
| Repeatability | ±0.1% of input span | ±0.1% of input span | ±0.1% of input span | ±0.1% of full scale |
| Alarm response | 50 milliseconds | 50 milliseconds for a 1% of span step | 50 milliseconds for a 1% of span step | 50 msec |
| Isolation | 500Vac, input to output to power | input, output and power with no dc connections | input, output and power with no dc connections | 1500Vrms between input, output and power |
Request a price and lead time
DDA DIN-Style Current and Voltage Limit Alarm Trip, 1-5V Input. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which input signals does the DDA accept?
All standard process current and voltage inputs from transmitters and transducers; the DDA/1-5V/SH1/24DC model has a 1-5V input.
How are the trip points set?
With multiturn potentiometers on the front panel, and the integral display shows the settings and the input signal.
Is a dual alarm version available?
Yes, dual models give two separate trip points: High/Low, High/High or Low/Low.