DDA DIN-Style Current and Voltage Limit Alarm Trip, 1-5V Input

The DDA accepts standard process current and voltage signals from transmitters and transducers and gives a contact closure when the input crosses a preset limit. The DDA/1-5V/SH1/24DC variant has one high-set failsafe alarm, a display and 24VDC power.

Type
current and voltage limit alarm trip
Model
DDA/1-5V/SH1/24DC [DIN]
Input
1-5V
Output
single alarm, set as high, failsafe, contact closure

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Standard process current and voltage inputs from field transmitters and transducers go into the DDA. When the input value falls outside a fully adjustable preset limit, the unit closes a contact to indicate a high and/or low condition through a bell, buzzer, light or other device. A typical model is DDA/1-5V/SH1/24DC: 1-5V input, a single alarm set as high and failsafe, and 4-wire 24VDC power.

Single and dual alarm models are offered. The dual models allow two separate trip points per module, configured as High/Low, High/High or Low/Low. Trip points are set with multiturn potentiometers on the front panel, and the integral display shows the upper and lower settings as well as the input signal. High/Low selection is made with internal solderless jumpers. Front-panel LEDs show the alarm state; an LED that is on means the relay is energised.

The display shows the input in percentage as standard, or in engineering units with the -EU option. Other options include 2-wire transmitter excitation and adjustable deadband. Complete input, output and power isolation, together with built-in RFI/EMI protection, prevents false alarms in noisy environments.

Display accuracy is ±0.1% of input span ±1 count, and the trip point repeats within ±0.1% of input span. Standard deadband is 1% of input span, alarm response is 50 milliseconds, and isolation is 500Vac between input, output and power. The ambient range is -18°C to +65°C, and trip points adjust over -5% to 105% of span, typically. The DIN housing mounts on a 35mm Top Hat rail. Approvals: CSA general (ordinary) location, and CE conformance.

Technical specifications

Typecurrent and voltage limit alarm trip
ModelDDA/1-5V/SH1/24DC [DIN]
Input1-5V
Outputsingle alarm, set as high, failsafe, contact closure
Power4-wire, 24VDC
Displayintegral
Configurationface-plate configurable
Display accuracy±0.1% of input span, ±1 count
Repeatability±0.1% of input span
Dead band1% of input span (standard)
Alarm response50 milliseconds
Isolation500Vac, input to output to power
Ambient range-18°C to +65°C
HousingDIN-style, 35mm Top Hat rail

How it compares with similar models

ParameterDDA DIN-Style Current and Voltage Limit Alarm Trip, 1-5V InputRBA-STD RTD (Resistance Bulb) Alarm, 4-Wire, Single or Dual TripTCA Thermocouple Alarm for ISA Thermocouples, 4-Wire, Single or Dual TripECA DIN rail current and voltage limit alarm trip, two relays, 24DC supply
Typecurrent and voltage limit alarm tripRTD alarm, 4-wirethermocouple alarm, 4-wirecurrent and voltage limit alarm trip
Input1-5V2-wire or 3-wire RTDany standard ISA thermocouple1-5VDC
Power4-wire, 24VDC117 Vac or 220 Vac, 50/60Hz; dc117, 220 or 240 Vac 50/60Hz ±10%; 24 or 45 Vdc ±10%24DC, 4-wire
Repeatability±0.1% of input span±0.1% of input span±0.1% of input span±0.1% of full scale
Alarm response50 milliseconds50 milliseconds for a 1% of span step50 milliseconds for a 1% of span step50 msec
Isolation500Vac, input to output to powerinput, output and power with no dc connectionsinput, output and power with no dc connections1500Vrms between input, output and power

Request a price and lead time

DDA DIN-Style Current and Voltage Limit Alarm Trip, 1-5V Input. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which input signals does the DDA accept?

All standard process current and voltage inputs from transmitters and transducers; the DDA/1-5V/SH1/24DC model has a 1-5V input.

How are the trip points set?

With multiturn potentiometers on the front panel, and the integral display shows the settings and the input signal.

Is a dual alarm version available?

Yes, dual models give two separate trip points: High/Low, High/High or Low/Low.