SPA2IS Site Programmable Alarm Trip with Built-in Intrinsically Safe Barrier
A site programmable alarm trip classed as associated intrinsically safe equipment. Its intrinsic safety barrier is built into the unit, so temperature sensors and transmitters in Class I Div 1 or Zone 0/1 hazardous areas connect to it directly.
- Type
- programmable alarm trip
- Protection method
- associated intrinsically safe equipment (IS)
- Intrinsic safety barrier
- built in
- Sensor connection from zones
- Class I Div 1 or Zone 0/1
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Many plants run processes that can create explosive atmospheres, and alarm points located in those areas need to be monitored. When intrinsic safety is chosen as the protection method, a separate barrier is normally needed for every 4-20mA, RTD and TC signal. These barriers are costly, demand considerable engineering effort and take up valuable panel space.
The SPA2IS takes a different route. Its intrinsic safety barrier sits inside the instrument, so it counts as associated IS equipment that can connect straight to temperature elements and transmitters installed in Class I Div 1 or Zone 0/1 hazardous areas. External barriers and the marshalling cabinet that houses them are no longer needed, which saves time and money on the project.
The unit is approved for installation in Class I Div 2/Zone 2 locations. It provides four programmable SPDT relays for alarm and trip duties, plus an optional auxiliary analogue output for passing the signal to a control system or indicator. One device therefore replaces the external barrier and a separate alarm unit, leaving fewer components and connections in the cabinet.
Set-up is carried out with the push buttons on the instrument or with free PC software. The settings cover the input type, the trip set points and the logic that governs the relays. Typical users include oil and gas upstream and downstream operations, power generation and transmission, chemical and specialty chemical plants, pharmaceutical and biotechnology sites, pulp and paper mills, mining and metal refining, water and wastewater treatment works, and food and beverage producers.
Technical specifications
| Type | programmable alarm trip |
|---|---|
| Protection method | associated intrinsically safe equipment (IS) |
| Intrinsic safety barrier | built in |
| Sensor connection from zones | Class I Div 1 or Zone 0/1 |
| Installation zone of the instrument | Class I Div 2/Zone 2 |
| Input signals | 4-20mA, RTD, TC |
| Relay outputs | four programmable SPDT |
| Analogue output | auxiliary, optional |
| Programming | push buttons on the instrument or free PC software |
Part numbers
Show all part numbers (1)
SPA2IS
Request a price and lead time
SPA2IS Site Programmable Alarm Trip with Built-in Intrinsically Safe Barrier. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Are external intrinsic safety barriers needed?
No. The barrier is built into the SPA2IS, so sensors in Class I Div 1 or Zone 0/1 areas connect to it directly.
Where can the instrument itself be installed?
The SPA2IS is approved for installation in Class I Div 2/Zone 2 areas.
How many relay outputs does the alarm trip have?
It has four programmable SPDT relays, and an optional auxiliary analogue output is also available.