MVA Millivolt Alarm, 4-Wire, Single or Dual Trip

The MVA takes input from any millivolt source, such as transducers and gas and pH analysers, and closes a contact when the value leaves a preset limit. Accuracy is within ±0.1% of span, in single and dual alarm models.

Type
millivolt alarm, 4-wire
Inputs
0-10mV, 0-25mV, 0-100mV, 0-400mV, 0-1V, 0-10V
Input impedance
1 megohm
Accuracy
±0.1% of span

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The MVA accepts input from any millivolt source, including transducers, gas and pH analysers and the like. When the input value falls outside a fully adjustable preset limit, it gives a contact closure that can indicate a high and/or low condition through a bell, buzzer, light or other device. A bright LED on the front panel shows that an alarm condition has occurred.

Accuracy is within ±0.1% of span. Single and dual alarm models are offered, and the dual models allow two separate trip points per module, set as High/Low, High/High or Low/Low. On both, trip points are set with potentiometers on the front panel. Input ranges listed include 0-10mV, 0-25mV, 0-100mV, 0-400mV, 0-1V and 0-10V. The one megohm input impedance is high enough not to affect the output of the device being monitored.

Input, output and power input are isolated, with no dc connections between them, in both ac and dc powered units. Trip points repeat within ±0.1% of input span, standard deadband is 1% of span, and alarm response is 50 milliseconds for a step change of 1% of span beyond the trip point. The ambient range is -18°C to +65°C with an effect of less than ±0.018%/°C, trip points adjust over 0% to 100% of span, and weight is approximately 908 grams.

Options are a ten-turn lockable dial with vernier scale (-TT), adjustable deadband (-AD), an alarm response delay of 1 to 30 seconds set at the factory (-AR), RFI/EMI protection (-RF), hermetically sealed relays (-HS), manual reset (-MR) and upscale open input drive (-UD). Housings are a surface-mount version and a high-density plug-in card version for control rooms, plus a field-mount enclosure. Approvals: CSA general location and hazardous location Class I, Groups B, C, D, and City of Los Angeles general location.

Technical specifications

Typemillivolt alarm, 4-wire
Inputs0-10mV, 0-25mV, 0-100mV, 0-400mV, 0-1V, 0-10V
Input impedance1 megohm
Accuracy±0.1% of span
Repeatability±0.1% of input span
Dead band1% of span, standard
Alarm response50 milliseconds for a 1% of span step
Isolationinput, output and power with no dc connections
Ambient range-18°C to +65°C
Trip point adjustment0% to 100% of span, multiturn potentiometers
Weightapproximately 908 grams

How it compares with similar models

ParameterMVA Millivolt Alarm, 4-Wire, Single or Dual TripRBA-STD RTD (Resistance Bulb) Alarm, 4-Wire, Single or Dual TripTCA Thermocouple Alarm for ISA Thermocouples, 4-Wire, Single or Dual TripDDA DIN-Style Current and Voltage Limit Alarm Trip, 1-5V Input
Typemillivolt alarm, 4-wireRTD alarm, 4-wirethermocouple alarm, 4-wirecurrent and voltage limit alarm trip
Alarm response50 milliseconds for a 1% of span step50 milliseconds for a 1% of span step50 milliseconds for a 1% of span step50 milliseconds
Isolationinput, output and power with no dc connectionsinput, output and power with no dc connectionsinput, output and power with no dc connections500Vac, input to output to power
Trip point adjustment0% to 100% of span, multiturn potentiometers0% to 100% of span0% to 100% of span—

Request a price and lead time

MVA Millivolt Alarm, 4-Wire, Single or Dual Trip. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which signal sources connect to the MVA?

Any millivolt source such as transducers and gas or pH analysers, with inputs from 0-10mV to 0-10V.

Can the alarm be delayed?

Yes, the -AR option sets a delay of 1 to 30 seconds at the factory.

What is the MVA input impedance?

One megohm, high enough not to affect the output of the monitored device.