EPX2 Explosion-Proof Voltage-to-Pressure (E/P) Transmitter, 1-5V to 3-15 psig, 3-Wire

The EPX2 converts a 1-5V voltage signal into a pneumatic signal so a DCS, PLC or PC can control valves, actuators and dampers. It has an explosion-proof aluminium NEMA 4X housing and accuracy under ±0.25% of span.

Type
explosion-proof voltage-to-pressure (E/P) transmitter, 3-wire
Input
1-5 Volts
Voltage input impedance
1 Mohm
Output
3-15psig; 0-30psig; 6-30psig

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The EPX2 is a 3-wire (auxiliary-powered), low-voltage E/P transmitter. It accepts a 1-5V input signal from a DCS, PLC or PC-based control system and converts it to a pneumatic signal (3-15psig, 0.2-1Bar, 20-100kPa and others) for precise, proportional control of valves, actuators and other pneumatically controlled devices. Voltage input impedance is 1 megohm.

The extruded aluminium housing is explosion-proof and waterproof, rated NEMA 4X, and the unit is made for extended duty in harsh field environments such as remote natural gas well heads. An optional coalescing filter/regulator combines an air filter, a miniature supply line regulator and a gauge reading in both psi and bars. With the -NG1 or -NG2 option the EPX2 can use natural gas as its pneumatic supply (sweet gas with up to 20ppm of H2S), so it can be installed at remote compressor sites where running a clean air supply is impossible or too expensive.

There are 22 direct and reverse output ranges, including 3-15psig, 0-30psig and 6-30psig. Accuracy is under ±0.25% of span including linearity, hysteresis and repeatability, with six-month stability. Output reaches 5SCFM while consumption is as low as 0.08SCFM. The low power requirement of 3mA at 12Vdc allows a battery or solar panel supply, and the power supply range is 9-30Vdc. Supply pressure changes between 20 and 40psig have a negligible effect on accuracy. A larger orifice with an easily replaceable internal filter protects against clogging.

Step response is under 0.2 seconds into a 100ml load (6 in3) from 10% to 90% of span. Air capacity is at least 5.0SCFM and relief capacity at least 2.5SCFM. The air supply must be instrument air only, 20-40psig and 5psig above the maximum output. The ambient operating and storage range is -40°C to +85°C. Certification: CE conformant under EMC Directive 89/336/EEC, EN 61326.

Technical specifications

Typeexplosion-proof voltage-to-pressure (E/P) transmitter, 3-wire
Input1-5 Volts
Voltage input impedance1 Mohm
Output3-15psig; 0-30psig; 6-30psig
Power supply9-30Vdc
Accuracy<±0.25% of span
Step response<0.2 seconds into 100ml (6 in3), 10% to 90% of span
Air capacity5.0SCFM minimum
Relief capacity2.5SCFM minimum
Air supplyinstrument air only, 20-40psig
Operating and storage range-40°C to +85°C
Housingextruded aluminium, explosion-proof, NEMA 4X

Part numbers

Show all part numbers (1)

EPX2

How it compares with similar models

ParameterEPX2 Explosion-Proof Voltage-to-Pressure (E/P) Transmitter, 1-5V to 3-15 psig, 3-WireIPT2 Current-to-Pressure (I/P) Transmitter, 4-20mA to 3-15 psig, DIN RailIPX2 Explosion-Proof and Intrinsically-Safe Current-to-Pressure (I/P) Transmitter, Field MountSIX 1-5V/4-20mA 2-Wire Signal Isolator and Converter, 1500 Vrms Isolation
Typeexplosion-proof voltage-to-pressure (E/P) transmitter, 3-wirecurrent-to-pressure (I/P) transmitterfield-mount current-to-pressure (I/P) transmitter, 2-wireSignal isolator, converter and repeater, 2-wire
Input1-5 Volts4-20mA (also 4-12mA, 12-20mA)4-12mA1-5 V
Output3-15psig; 0-30psig; 6-30psig3-15psig (also 0.2-1 Bar, 20-100kPA)3-15PSIG4-20 mA
Accuracy<±0.25% of span<±0.25% of span<±0.25% of span+/-0.1 % of span
Step response<0.2 seconds into 100ml (6 in3), 10% to 90% of span<0.2 seconds into 100ml (6 in3), 10% to 90% of span<0.25 seconds into 100ml (6 in3), 10% to 90% of span—
Air capacity5.0SCFM minimumminimum 2.0 SCFM5.0SCFM minimum—

Request a price and lead time

EPX2 Explosion-Proof Voltage-to-Pressure (E/P) Transmitter, 1-5V to 3-15 psig, 3-Wire. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What input does the EPX2 take?

A 1-5V signal with 1 megohm input impedance, and a 9-30Vdc supply.

Can the EPX2 run on natural gas?

Yes, with the -NG1 or -NG2 option, on gas as clean as instrument air with H2S not exceeding 20ppm.

Can it run from a battery or solar panel?

Yes, the 3mA at 12Vdc requirement allows a battery or solar panel supply.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00