International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

PIH Field-Mount Pressure-to-Current Transmitter, 0-15 psig to 4-20mA, NEMA 4X

The PIH converts a pneumatic signal into a proportional 4-20mA current for a data acquisition system, controller or recorder. It has an aluminium NEMA 4X/IP64 housing, a 600 ohm load capability at 24Vdc and ±0.2% of span accuracy.

Type
field-mount pressure-to-current (P/I) transmitter
Input
0-15PSIG (also 3-15, 0-30, 3-27, 6-30 PSIG, .2-1BAR, .2-1KGCM2, 20-100KPA, 20-186KPA)
Output
4-20mA
Loop power
12-42Vdc

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The PIH is a field-mounted pressure-to-current transmitter for processes that need a rugged instrument to link a pneumatic device with a data acquisition/control system, controller, recorder or other electronic instrument. It accepts most pneumatic signals and accurately converts them to a proportional 4-20mA output. The typical model is PIH/0-15PSIG/4-20mA/12-42DC [WDNS]: 0-15psig input, 4-20mA output and a 12-42Vdc loop supply.

Inputs available are 0-15, 3-15, 0-30, 3-27 and 6-30 psig, 0.2-1 bar, 0.2-1 kgcm2, 20-100 kPa and 20-186 kPa. The -RO option gives a reverse output, so that the output current decreases as the input increases. The body is aluminium with a black PBT polyester cover, with NPT pneumatic ports and a ½-inch NPT female electrical entry port. The housing is watertight, dust-tight and resistant to corrosion and chemicals, in a NEMA 4X/IP64 field-mount enclosure. A metal cover weighs 808 grams and a polyester cover 623.5 grams. The metal casing gives strength without the added expense of an explosion-proof enclosure.

The PIH is immune to shock, vibration and mounting position. Running electrical wiring in place of fragile pneumatic tubing from remote pneumatic devices lowers installation costs. Calibration error is within ±0.2% of span including independent linearity as defined in SAMA PMC 20.1-1973, repeatability is within ±0.1% of input span and resolution is ±0.05%. Load capability is 600 ohms at a nominal 24Vdc. Input pressure of 150% of full scale causes no damage, and the output limit is 130% of output span. The ambient range is -1°C to +54°C with an effect of less than ±2.0% of full scale. Span adjusts to 100% of output span and zero adjusts 0 to ±10%. The unit is CE conformant under EMC Directive 2014/30/EU, EN 61326.

Technical specifications

Typefield-mount pressure-to-current (P/I) transmitter
Input0-15PSIG (also 3-15, 0-30, 3-27, 6-30 PSIG, .2-1BAR, .2-1KGCM2, 20-100KPA, 20-186KPA)
Output4-20mA
Loop power12-42Vdc
Calibration capability±0.2% of span including linearity
Repeatability±0.1% of input span
Load capability600 ohms at nominal 24Vdc
Ambient range-1°C to +54°C
Housingaluminium body, PBT polyester cover, NEMA 4X/IP64
ConnectionsNPT pneumatic, ½-inch NPT electrical
Weight808 grams (metal cover); 623.5 grams (polyester cover)
Options-RO (reverse output)

Part numbers

Show all part numbers (1)

PIH/0-15PSIG/4-20mA/12-42DC [WDNS]

How it compares with similar models

ParameterPIH Field-Mount Pressure-to-Current Transmitter, 0-15 psig to 4-20mA, NEMA 4XPIT DIN-Rail Pressure-to-Current Transmitter, 3-15 psig to 4-20mAPIX Explosion-Proof Pressure-to-Current Transmitter, 0.2-1 bar to 4-20mA, Field MountIPH2 NEMA 4X Current-to-Pressure (I/P) Transmitter, 4-20mA to 3-15 psig, Field Mount
Typefield-mount pressure-to-current (P/I) transmitterpressure-to-current (P/I) transmitter, DIN versionexplosion-proof field-mount pressure-to-current (P/I) transmitterfield-mount current-to-pressure (I/P) transmitter
Input0-15PSIG (also 3-15, 0-30, 3-27, 6-30 PSIG, .2-1BAR, .2-1KGCM2, 20-100KPA, 20-186KPA)3-15PSIG0.2-1 BAR (also 3-15 PSIG, 0.2-1 KGCM2, 6-30 PSIG)4-20mA (also 4-12mA, 12-20mA)
Output4-20mA4-20mA4-20mA3-15PSIG (also 6-30PSIG, 3-27PSIG, 0.2-1BAR, 20-100KPA)
Loop power12-42Vdc12-24Vdc (12-42DC listed for supply/loop power)12-42Vdc (also 12-24Vdc)—
Housingaluminium body, PBT polyester cover, NEMA 4X/IP64—extruded aluminium, explosion-proof, NPT conduit entryaluminium body and cover, NPT entry ports

Request a price and lead time

PIH Field-Mount Pressure-to-Current Transmitter, 0-15 psig to 4-20mA, NEMA 4X. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which input ranges does the PIH have?

0-15, 3-15, 0-30, 3-27 and 6-30 psig, 0.2-1 bar, 0.2-1 kgcm2, 20-100 kPa and 20-186 kPa, with a 4-20mA output.

Is a reverse output available?

Yes, the -RO option makes the output decrease as the input increases.

What loop load is allowed?

600 ohms at a nominal 24Vdc, with a load effect of ±0.01% of span.