IPT2 Current-to-Pressure (I/P) Transmitter, 4-20mA to 3-15 psig, DIN Rail
The IPT2 converts a current signal into a pneumatic signal so that a DCS, PLC or PC can control a pneumatic actuator, valve or damper drive. Accuracy is under ±0.25% of span, in a 40mm wide housing that snaps onto a rail.
- Type
- current-to-pressure (I/P) transmitter
- Model
- IPT2/4-20mA/3-15PSIG/20PSI/-FA1 [DIN]
- Input
- 4-20mA (also 4-12mA, 12-20mA)
- Output
- 3-15psig (also 0.2-1 Bar, 20-100kPA)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
A current signal from a DCS, PLC or PC enters the IPT2, which turns it into a proportional pneumatic signal for a pneumatic actuator, valve or damper drive. Available models accept 4-20mA, 4-12mA and 12-20mA inputs and give outputs such as 3-15psig, 0.2-1 Bar and 20-100kPA. A typical model is IPT2/4-20mA/3-15PSIG/20PSI/-FA1: 4-20mA input, 3-15psig output, 20psi supply, air as the supply and output medium, and the -FA1 option for a front electrical connection with the pneumatic connection at the bottom.
The housing is aluminium, 40mm wide, and snaps onto a standard mounting rail or onto a pneumatic header rack such as the RIR or SIR. A mounting block snaps onto the rail; units ordered without one clip onto an RIR or SIR, which feeds air to each unit through a single supply pipe. Blocks and headers contain self-sealing valves, so an IPT2 can be removed and replaced without disturbing the pneumatic connections or venting the supply or output air. Operation can be monitored, or calibration performed, through the electrical input and the optional pneumatic output test jacks. A red LED that varies in intensity with the input current is standard.
The closed-loop design responds quickly to step changes, improves accuracy and reduces drift. Accuracy is under ±0.25% of span including linearity, hysteresis and repeatability (between 0.5 and 3psi output the error will not exceed ±1.0% of span), with stability that does not degrade for six months. Step response is under 0.2 seconds into a 100ml load (6 in3) from 10% to 90% of span. Eighteen standard output ranges are offered. Air consumption is 0.08 SCFM typical (0.18 kg/hr) and air capacity is at least 2.0 SCFM. Supply pressure changes between 20 and 40psi have a negligible effect. A larger orifice with an external cleaning plunger resists clogging, and the mechanical assembly prevents sticking on cold restart.
The air supply must be instrument air only, 20-40psig and 5psig above the maximum output. Voltage drop is 7.5V maximum (5V without the LED). Ambient operating and storage range is -40°C to +80°C. Shock and vibration effect is 0.25%/G or better over 5-15Hz, meeting SAMA PMC 31.3. Approvals: CE conformant under EMC Directive 2014/30/EU, EN61326, and FM Approvals Non-Incendive, Class I, Division 2, Groups A, B, C and D, temperature class T5, Tamb -40°C to +80°C.
Technical specifications
| Type | current-to-pressure (I/P) transmitter |
|---|---|
| Model | IPT2/4-20mA/3-15PSIG/20PSI/-FA1 [DIN] |
| Input | 4-20mA (also 4-12mA, 12-20mA) |
| Output | 3-15psig (also 0.2-1 Bar, 20-100kPA) |
| Accuracy | <±0.25% of span |
| Air supply | instrument air only, 20-40psig |
| Air consumption | 0.08 SCFM typical (0.18 kg/hr) |
| Air capacity | minimum 2.0 SCFM |
| Step response | <0.2 seconds into 100ml (6 in3), 10% to 90% of span |
| Voltage drop | 7.5V maximum (5V without LED) |
| Ambient operating and storage range | -40°C to +80°C |
| Housing | aluminium, 40mm wide, G-type and Top Hat DIN rail or rack mount |
| Hazardous area certifications | Non-Incendive/Div. 2, Zone 2 |
How it compares with similar models
| Parameter | IPT2 Current-to-Pressure (I/P) Transmitter, 4-20mA to 3-15 psig, DIN Rail | EPX2 Explosion-Proof Voltage-to-Pressure (E/P) Transmitter, 1-5V to 3-15 psig, 3-Wire | PIT DIN-Rail Pressure-to-Current Transmitter, 3-15 psig to 4-20mA | IPX2 Explosion-Proof and Intrinsically-Safe Current-to-Pressure (I/P) Transmitter, Field Mount |
|---|---|---|---|---|
| Type | current-to-pressure (I/P) transmitter | explosion-proof voltage-to-pressure (E/P) transmitter, 3-wire | pressure-to-current (P/I) transmitter, DIN version | field-mount current-to-pressure (I/P) transmitter, 2-wire |
| Input | 4-20mA (also 4-12mA, 12-20mA) | 1-5 Volts | 3-15PSIG | 4-12mA |
| Output | 3-15psig (also 0.2-1 Bar, 20-100kPA) | 3-15psig; 0-30psig; 6-30psig | 4-20mA | 3-15PSIG |
| Air capacity | minimum 2.0 SCFM | 5.0SCFM minimum | — | 5.0SCFM minimum |
| Step response | <0.2 seconds into 100ml (6 in3), 10% to 90% of span | <0.2 seconds into 100ml (6 in3), 10% to 90% of span | — | <0.25 seconds into 100ml (6 in3), 10% to 90% of span |
| Housing | aluminium, 40mm wide, G-type and Top Hat DIN rail or rack mount | extruded aluminium, explosion-proof, NEMA 4X | — | explosion-proof aluminium, ½-inch NPT entry, NEMA 4X/IP66 |
Request a price and lead time
IPT2 Current-to-Pressure (I/P) Transmitter, 4-20mA to 3-15 psig, DIN Rail. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What are the IPT2 input and output signals?
Inputs are 4-20mA, 4-12mA or 12-20mA; outputs include 3-15psig, 0.2-1 Bar and 20-100kPA, with 18 standard ranges.
What air supply does the IPT2 need?
Instrument air only, 20-40psig and 5psig above the maximum output; supply changes between 20 and 40psi have a negligible effect.
Can an IPT2 be replaced without venting the air?
Yes, the mounting blocks and headers contain self-sealing valves, so the unit comes out without disturbing the pneumatic connections.
Similar equipment from other manufacturers