PIX Explosion-Proof Pressure-to-Current Transmitter, 0.2-1 bar to 4-20mA, Field Mount
The PIX converts a pneumatic signal into a proportional 4-20mA current. It has an extruded aluminium explosion-proof NEMA 4X/IP66 housing with an NPT conduit entry, and a 12-42Vdc loop supply.
- Type
- explosion-proof field-mount pressure-to-current (P/I) transmitter
- Input
- 0.2-1 BAR (also 3-15 PSIG, 0.2-1 KGCM2, 6-30 PSIG)
- Output
- 4-20mA
- Loop power
- 12-42Vdc (also 12-24Vdc)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The PIX is a field-mounted explosion-proof pressure-to-current transmitter made for installation in harsh environments. It converts a variable pneumatic input into a proportional 4-20mA current signal for process measurement and control loops. The typical model is PIX/.2-1BAR/4-20mA/12-42DC [EXI]: 0.2-1 bar input, 4-20mA output, a 12-42Vdc loop supply and air as the medium.
The unit accepts instrument-quality air, and as the input pressure rises the output current rises toward 20mA. Power comes from the 12-42Vdc loop. Zero and span are set with potentiometers that do not interact. The housing is extruded explosion-proof aluminium with an NPT conduit entry port (FM approved), rated NEMA 4X/IP66, for field mounting. Explosion-proof and non-incendive (Div. 2, Zone 2) certifications are listed.
Options include intrinsic safety (IS), reverse output (RO), a pneumatic test jack (PTJ), an input gauge (GA1), pipe mount hardware and a DIN rail adapter. The unit is CE conformant under EMC Directive 2014/30/EU.
The PIX range covers inputs of 3-15 psig, 0.2-1 bar, 0.2-1 kgcm2 and 6-30 psig, with 12-42Vdc or 12-24Vdc supply. The code in square brackets (EXI, EXIP, P3LS, P3LSP, FL, HP) identifies the housing version. The unit needs bench checking before installation.
Technical specifications
| Type | explosion-proof field-mount pressure-to-current (P/I) transmitter |
|---|---|
| Input | 0.2-1 BAR (also 3-15 PSIG, 0.2-1 KGCM2, 6-30 PSIG) |
| Output | 4-20mA |
| Loop power | 12-42Vdc (also 12-24Vdc) |
| Medium | air |
| Housing | extruded aluminium, explosion-proof, NPT conduit entry |
| Enclosure | NEMA 4X/IP66 |
| Installation | field mount |
| Hazardous area certifications | Explosion Proof, Non-Incendive/Div. 2, Zone 2 |
| Options | IS, RO, PTJ, GA1 |
Part numbers
Show all part numbers (5)
PIX/.2-1BAR/4-20mA/12-42DC [EXI], PIX/3-15PSIG/4-20mA/12-42DC [EXI], PIX/3-15PSIG/4-20mA/12-42DC [EXIP], PIX/6-30PSIG/4-20mA/12-42DC [EXI], PIX/.2-1KGCM2/4-20mA/12-42DC [EXI]
How it compares with similar models
| Parameter | PIX Explosion-Proof Pressure-to-Current Transmitter, 0.2-1 bar to 4-20mA, Field Mount | IPX2 Explosion-Proof and Intrinsically-Safe Current-to-Pressure (I/P) Transmitter, Field Mount | IPH2 NEMA 4X Current-to-Pressure (I/P) Transmitter, 4-20mA to 3-15 psig, Field Mount | PIH Field-Mount Pressure-to-Current Transmitter, 0-15 psig to 4-20mA, NEMA 4X |
|---|---|---|---|---|
| Type | explosion-proof field-mount pressure-to-current (P/I) transmitter | field-mount current-to-pressure (I/P) transmitter, 2-wire | field-mount current-to-pressure (I/P) transmitter | field-mount pressure-to-current (P/I) transmitter |
| Input | 0.2-1 BAR (also 3-15 PSIG, 0.2-1 KGCM2, 6-30 PSIG) | 4-12mA | 4-20mA (also 4-12mA, 12-20mA) | 0-15PSIG (also 3-15, 0-30, 3-27, 6-30 PSIG, .2-1BAR, .2-1KGCM2, 20-100KPA, 20-186KPA) |
| Output | 4-20mA | 3-15PSIG | 3-15PSIG (also 6-30PSIG, 3-27PSIG, 0.2-1BAR, 20-100KPA) | 4-20mA |
| Housing | extruded aluminium, explosion-proof, NPT conduit entry | explosion-proof aluminium, ½-inch NPT entry, NEMA 4X/IP66 | aluminium body and cover, NPT entry ports | aluminium body, PBT polyester cover, NEMA 4X/IP64 |
| Hazardous area certifications | Explosion Proof, Non-Incendive/Div. 2, Zone 2 | Intrinsically-Safe, Explosion Proof, Flameproof, Non-Incendive/Div. 2, Zone 2 | Intrinsically-Safe, Non-Incendive/Div. 2, Zone 2 | — |
Request a price and lead time
PIX Explosion-Proof Pressure-to-Current Transmitter, 0.2-1 bar to 4-20mA, Field Mount. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What medium and power does the PIX need?
Instrument-quality air at the input and a 12-42Vdc loop supply, with a 4-20mA output.
Which options are available?
Intrinsic safety (IS), reverse output (RO), pneumatic test jack (PTJ), input gauge (GA1), pipe mount hardware and a DIN rail adapter.
What is the housing rating?
NEMA 4X/IP66, explosion-proof extruded aluminium with an NPT conduit entry.