International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

PIX Explosion-Proof Pressure-to-Current Transmitter, 0.2-1 bar to 4-20mA, Field Mount

The PIX converts a pneumatic signal into a proportional 4-20mA current. It has an extruded aluminium explosion-proof NEMA 4X/IP66 housing with an NPT conduit entry, and a 12-42Vdc loop supply.

Type
explosion-proof field-mount pressure-to-current (P/I) transmitter
Input
0.2-1 BAR (also 3-15 PSIG, 0.2-1 KGCM2, 6-30 PSIG)
Output
4-20mA
Loop power
12-42Vdc (also 12-24Vdc)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The PIX is a field-mounted explosion-proof pressure-to-current transmitter made for installation in harsh environments. It converts a variable pneumatic input into a proportional 4-20mA current signal for process measurement and control loops. The typical model is PIX/.2-1BAR/4-20mA/12-42DC [EXI]: 0.2-1 bar input, 4-20mA output, a 12-42Vdc loop supply and air as the medium.

The unit accepts instrument-quality air, and as the input pressure rises the output current rises toward 20mA. Power comes from the 12-42Vdc loop. Zero and span are set with potentiometers that do not interact. The housing is extruded explosion-proof aluminium with an NPT conduit entry port (FM approved), rated NEMA 4X/IP66, for field mounting. Explosion-proof and non-incendive (Div. 2, Zone 2) certifications are listed.

Options include intrinsic safety (IS), reverse output (RO), a pneumatic test jack (PTJ), an input gauge (GA1), pipe mount hardware and a DIN rail adapter. The unit is CE conformant under EMC Directive 2014/30/EU.

The PIX range covers inputs of 3-15 psig, 0.2-1 bar, 0.2-1 kgcm2 and 6-30 psig, with 12-42Vdc or 12-24Vdc supply. The code in square brackets (EXI, EXIP, P3LS, P3LSP, FL, HP) identifies the housing version. The unit needs bench checking before installation.

Technical specifications

Typeexplosion-proof field-mount pressure-to-current (P/I) transmitter
Input0.2-1 BAR (also 3-15 PSIG, 0.2-1 KGCM2, 6-30 PSIG)
Output4-20mA
Loop power12-42Vdc (also 12-24Vdc)
Mediumair
Housingextruded aluminium, explosion-proof, NPT conduit entry
EnclosureNEMA 4X/IP66
Installationfield mount
Hazardous area certificationsExplosion Proof, Non-Incendive/Div. 2, Zone 2
OptionsIS, RO, PTJ, GA1

Part numbers

Show all part numbers (5)

PIX/.2-1BAR/4-20mA/12-42DC [EXI], PIX/3-15PSIG/4-20mA/12-42DC [EXI], PIX/3-15PSIG/4-20mA/12-42DC [EXIP], PIX/6-30PSIG/4-20mA/12-42DC [EXI], PIX/.2-1KGCM2/4-20mA/12-42DC [EXI]

How it compares with similar models

ParameterPIX Explosion-Proof Pressure-to-Current Transmitter, 0.2-1 bar to 4-20mA, Field MountIPX2 Explosion-Proof and Intrinsically-Safe Current-to-Pressure (I/P) Transmitter, Field MountIPH2 NEMA 4X Current-to-Pressure (I/P) Transmitter, 4-20mA to 3-15 psig, Field MountPIH Field-Mount Pressure-to-Current Transmitter, 0-15 psig to 4-20mA, NEMA 4X
Typeexplosion-proof field-mount pressure-to-current (P/I) transmitterfield-mount current-to-pressure (I/P) transmitter, 2-wirefield-mount current-to-pressure (I/P) transmitterfield-mount pressure-to-current (P/I) transmitter
Input0.2-1 BAR (also 3-15 PSIG, 0.2-1 KGCM2, 6-30 PSIG)4-12mA4-20mA (also 4-12mA, 12-20mA)0-15PSIG (also 3-15, 0-30, 3-27, 6-30 PSIG, .2-1BAR, .2-1KGCM2, 20-100KPA, 20-186KPA)
Output4-20mA3-15PSIG3-15PSIG (also 6-30PSIG, 3-27PSIG, 0.2-1BAR, 20-100KPA)4-20mA
Housingextruded aluminium, explosion-proof, NPT conduit entryexplosion-proof aluminium, ½-inch NPT entry, NEMA 4X/IP66aluminium body and cover, NPT entry portsaluminium body, PBT polyester cover, NEMA 4X/IP64
Hazardous area certificationsExplosion Proof, Non-Incendive/Div. 2, Zone 2Intrinsically-Safe, Explosion Proof, Flameproof, Non-Incendive/Div. 2, Zone 2Intrinsically-Safe, Non-Incendive/Div. 2, Zone 2—

Request a price and lead time

PIX Explosion-Proof Pressure-to-Current Transmitter, 0.2-1 bar to 4-20mA, Field Mount. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What medium and power does the PIX need?

Instrument-quality air at the input and a 12-42Vdc loop supply, with a 4-20mA output.

Which options are available?

Intrinsic safety (IS), reverse output (RO), pneumatic test jack (PTJ), input gauge (GA1), pipe mount hardware and a DIN rail adapter.

What is the housing rating?

NEMA 4X/IP66, explosion-proof extruded aluminium with an NPT conduit entry.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides