RBA-STD RTD (Resistance Bulb) Alarm, 4-Wire, Single or Dual Trip
The RBA takes input from any 2- or 3-wire RTD and closes a contact when the value leaves a preset limit. Accuracy is within ±0.1% of span, in single and dual alarm models, with the standard RBA-STD housing.
- Type
- RTD alarm, 4-wire
- Input
- 2-wire or 3-wire RTD
- Resistance span
- 10, 25, 100, 400 ohms
- Accuracy
- ±0.1% of span
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The RBA accepts input from any 2- or 3-wire RTD. When the input value falls outside a fully adjustable preset limit, it gives a contact closure that can indicate a high and/or low condition through a bell, buzzer, light or other device. A bright LED on the front panel shows that an alarm condition has occurred.
Accuracy is within ±0.1% of span. Single and dual alarm models are offered, and the dual models allow two separate trip points per module, set as High/Low, High/High or Low/Low. On both, trip points are set with potentiometers on the front panel. The input is specified as a 2-wire (2W) or 3-wire (3W) RTD, with spans of 10, 25, 100 or 400 ohms of resistance change. The SPDT relay contacts let the user choose either normally open or normally closed operation; DPDT relays are optional.
Input, output and power input are isolated with no dc connections between them, in both ac and dc powered units. Trip points repeat within ±0.1% of input span, standard deadband is 1% of span, and alarm response is 50 milliseconds for a step change of 1% of span beyond the trip point. The ambient range is -18°C to +65°C with an effect of less than ±0.018%/°C, trip points adjust over 0% to 100% of span, and weight is approximately 908 grams.
Options are adjustable deadband of 1-20%, available up to 100% (-AD), an alarm response delay of 1 to 30 seconds set at the factory (-AR), a differential temperature alarm that takes two RTDs and alarms on the size of their difference, process variable indication by a voltage proportional to the input, and RFI/EMI protection (-RF). Power is 117 Vac or 220 Vac, 50/60Hz, or dc. The standard RBA-STD housing has a U-back bracket for surface mounting; a plug-in card housing and a field-mount enclosure are also offered. Approvals: CE conformant under EMC Directive 89/336/EEC, EN 50081-2 (1993) and EN 50082-2 (1995); CSA general and hazardous locations, Class I, Groups C and D; City of Los Angeles general locations.
Technical specifications
| Type | RTD alarm, 4-wire |
|---|---|
| Input | 2-wire or 3-wire RTD |
| Resistance span | 10, 25, 100, 400 ohms |
| Accuracy | ±0.1% of span |
| Repeatability | ±0.1% of input span |
| Deadband | 1% of span, standard |
| Alarm response | 50 milliseconds for a 1% of span step |
| Isolation | input, output and power with no dc connections |
| Power | 117 Vac or 220 Vac, 50/60Hz; dc |
| Ambient range | -18°C to +65°C |
| Trip point adjustment | 0% to 100% of span |
| Weight | approximately 908 grams |
How it compares with similar models
| Parameter | RBA-STD RTD (Resistance Bulb) Alarm, 4-Wire, Single or Dual Trip | TCA Thermocouple Alarm for ISA Thermocouples, 4-Wire, Single or Dual Trip | MVA Millivolt Alarm, 4-Wire, Single or Dual Trip | DDA DIN-Style Current and Voltage Limit Alarm Trip, 1-5V Input |
|---|---|---|---|---|
| Type | RTD alarm, 4-wire | thermocouple alarm, 4-wire | millivolt alarm, 4-wire | current and voltage limit alarm trip |
| Input | 2-wire or 3-wire RTD | any standard ISA thermocouple | — | 1-5V |
| Alarm response | 50 milliseconds for a 1% of span step | 50 milliseconds for a 1% of span step | 50 milliseconds for a 1% of span step | 50 milliseconds |
| Isolation | input, output and power with no dc connections | input, output and power with no dc connections | input, output and power with no dc connections | 500Vac, input to output to power |
| Power | 117 Vac or 220 Vac, 50/60Hz; dc | 117, 220 or 240 Vac 50/60Hz ±10%; 24 or 45 Vdc ±10% | — | 4-wire, 24VDC |
| Trip point adjustment | 0% to 100% of span | 0% to 100% of span | 0% to 100% of span, multiturn potentiometers | — |
Request a price and lead time
RBA-STD RTD (Resistance Bulb) Alarm, 4-Wire, Single or Dual Trip. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which sensors does the RBA work with?
Any 2- or 3-wire RTD, with spans of 10, 25, 100 or 400 ohms.
Is a temperature difference alarm available?
Yes, an option accepts two RTDs and alarms according to the size of their difference.
What alarm delay can be set?
The -AR option gives a delay of 1 to 30 seconds, set at the factory.