ECA Current Alarm Trip for 4–20 mA Signal, Two SPDT Relays, 5 A 250 VAC
The ECA is a current alarm unit for a 4–20 mA signal, with two SPDT relay outputs and loop power for the transmitter from a built-in 24 V DC source. Setpoints are adjustable from 0 to 110% of the input range, the response time is 50 ms and the adjustable deadband is 1 to 20%.
- Type
- current alarm unit
- Input
- 4–20 mA
- Transmitter supply
- TX option, 24 V DC, 25 mA
- Outputs
- 2 SPDT relays
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Aeration is part of secondary treatment at municipal and industrial wastewater works, and the most common arrangement is the activated sludge process. In industry, diffused aeration is often used, with air fed into a vessel of water flowing in the opposite direction to strip dissolved gases such as carbon dioxide, hydrogen sulphide and methane and to oxidise dissolved metals, iron among them. If the compressors cannot deliver the required flow to the air header, treatment stays incomplete.
To monitor air flow to the air-operated valves, the ECA raises an alarm when the flow falls. It powers a two-wire air flow transmitter and accepts its 4–20 mA signal. The TX option, at 24 V DC and 25 mA, removes the need for a separate auxiliary supply and extra wiring.
The unit has two SPDT relay outputs rated 5 A, 250 VAC as standard. The setpoints of both alarms are set by potentiometers on the front panel within 0 to 110% of the input range. For sensors compliant with NAMUR, one of the alarms can be set above 21 mA, where it indicates a failure of the transmitter.
Each alarm function is configured on site with jumpers: trip on a high or low limit, and fail-safe or normal relay action. Response time is 50 ms, and the deadband is adjustable from 1 to 20% for each alarm. Beyond water treatment, the unit is used in mining and metal refining and at oil and gas extraction sites. It mounts in a cabinet alongside other loop equipment, and setting the alarms needs no programming.
Technical specifications
| Type | current alarm unit |
|---|---|
| Input | 4–20 mA |
| Transmitter supply | TX option, 24 V DC, 25 mA |
| Outputs | 2 SPDT relays |
| Relay rating | 5 A, 250 VAC |
| Setpoint range | 0–110% of input range |
| Setpoint adjustment | potentiometers on the front panel |
| Alarm modes | high or low limit, fail-safe or normal relay action |
| Response time | 50 ms |
| Deadband | 1–20%, adjustable |
| Sensor diagnostics | alarm above 21 mA per NAMUR |
Part numbers
Show all part numbers (1)
ECA
Request a price and lead time
ECA Current Alarm Trip for 4–20 mA Signal, Two SPDT Relays, 5 A 250 VAC. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Does the sensor need a separate power supply?
No, the TX option supplies 24 V DC at 25 mA to the two-wire sensor. No separate wiring to an auxiliary supply is needed.
How does the ECA detect a sensor failure?
For NAMUR sensors, one of the alarms is set above 21 mA. A signal beyond that limit indicates a failure of the transmitter.
What load can the relays handle?
The two SPDT relays are rated at 5 A at 250 VAC. The trip mode of each is set by jumpers.
Similar equipment from other manufacturers






