Ta7000 Gas Purity Monitor for Ultra-High-Purity Gases, Detection Limit below 500 ppt

The ta7000 gas chromatograph measures impurities in ultra-high-purity gases at parts-per-trillion levels. The ta7000R version detects hydrogen and carbon monoxide with a reduction gas detector, while the ta7000F detects carbon dioxide, methane and non-methane hydrocarbons with a flame ionisation detector, with detection limits of both below 500 ppt.

Purpose
impurity monitoring in ultra-high-purity gases
Detector
RGD (ta7000R) or FID (ta7000F)
Measured impurities (ta7000R)
H2, CO
Measured impurities (ta7000F)
CO2, CH4, NMHC, CO

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ta7000 monitors the quality of ultra-high-purity (UHP) gases at the point where they enter the distribution network, including the outlets of purifiers. Typical industries are semiconductor production, LCD and OLED display manufacturing, air separation and other processes using high-purity gases. Continuous monitoring reveals contamination before it spreads through the pipework. Disturbances in distribution systems can come from exhausted component life, outgassing from materials and an overloaded purifier.

The unit is built on one platform: a dedicated sample handling system, a single high-sensitivity detector and on-board data processing electronics. The algorithm separates the useful signal from random electronic noise. Gas regulation and the calibration system are built in. Each instrument is set up for a particular base gas: nitrogen, argon, helium, oxygen, hydrogen or carbon dioxide.

There are two versions. The ta7000R, with a reduction gas detector (RGD), measures hydrogen and carbon monoxide, with an accuracy in EDL mode that is the greater of ±0.25 ppb or ±10% of reading, and a response time of five minutes to 99%. The ta7000F, with a flame ionisation detector (FID), measures carbon dioxide, methane, non-methane hydrocarbons and carbon monoxide. Its methane detection limit is below 0.5 ppb, and the limits for the other compounds are 0.8 ppb or lower, with a 99% response time of 10 minutes. The F version has a getter purifier for the carrier gas, which reduces impurities to below 100 ppt.

The measuring range is 0 to 199.9 ppb, the display resolution is 0.1 ppb and the communication ports output 0.01 ppb. Inlet pressure is 70 to 90 psig (4.8 to 6.2 bar) with stability of ±2%, the sample flow is 50 cm³/min and the return is vented to atmosphere. Carrier and sample inlets use 1/4 inch fittings. The recommended ambient temperature is 16 to 38 °C.

The graphic LCD is 100 x 150 mm and backlit, with an RS232 serial port and a printer port for concentration, chromatogram and diagnostic reports. 4-20 mA outputs for concentrations and status relay contacts are available as options. Power is 100–120 or 200–240 VAC, 50/60 Hz, and the unit requires a minimum of 5 A. The rack-mount chassis measures 430 x 180 x 670 mm and weighs 15.9 kg.

Technical specifications

Purposeimpurity monitoring in ultra-high-purity gases
DetectorRGD (ta7000R) or FID (ta7000F)
Measured impurities (ta7000R)H2, CO
Measured impurities (ta7000F)CO2, CH4, NMHC, CO
Detection limitbelow 500 ppt
Range0–199.9 ppb
Resolution0.1 ppb (display), 0.01 ppb (ports)
Response time to 99%5 minutes (RGD), 10 minutes (FID)
Inlet pressure70–90 psig (4.8–6.2 bar)
Sample flow rate50 cm³/min
Ambient temperature16 to 38 °C
InterfacesRS232, printer port, 4-20 mA (optional)
DisplayLCD 100 x 150 mm
Power supply100-120 / 200-240 VAC, 50/60 Hz
Dimensions430 x 180 x 670 mm
Weight15.9 kg

Part numbers

Show all part numbers (8)

ta7000R-N2, ta7000R-Ar, ta7000F-N2, ta7000F-Ar, ta7000F-He, ta7000F-O2, ta7000F-H2, ta7000F-CO2

Request a price and lead time

Ta7000 Gas Purity Monitor for Ultra-High-Purity Gases, Detection Limit below 500 ppt. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which version should be chosen to monitor hydrocarbons?

The ta7000F, with a flame ionisation detector. Its methane detection limit is below 0.5 ppb and the limits for the other compounds are 0.8 ppb or lower.

Can one instrument be used for different gases?

No, each instrument is set up for a particular base gas, for example ta7000F-N2 for nitrogen or ta7000F-Ar for argon.

What sample conditions are needed?

Inlet pressure of 70–90 psig (4.8–6.2 bar) with stability of ±2%, a sample flow of 50 cm³/min, and venting preferably to atmosphere.