Ta5000 isothermal gas chromatograph for trace impurities, RGD or FID detector, from 3 ppb

The ta5000 series comprises isothermal gas chromatographs for measuring impurities from ppm down to ppb levels. The ta5000R, with a reduction detector, measures H2, CO and unsaturated hydrocarbons, while the ta5000F, with a flame ionisation detector, measures CO2, CH4 and non-methane hydrocarbons.

Type
isothermal gas chromatograph
Models
ta5000R (RGD), ta5000F (FID)
Components ta5000R
H2, CO, unsaturated hydrocarbons
Components ta5000F
CO2, CH4, non-methane hydrocarbons

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ta5000 is used to check the purity of technical and speciality gases at trace levels. Typical tasks include monitoring impurities in bulk-supplied gases, air separation, production of polyethylene and polypropylene, hydrocarbon processing, LCD, OLED and semiconductor manufacturing, verifying the performance of gas purifiers, and environmental or laboratory measurement. Specific applications cover dissolved H2 in water, CO in the atmosphere, ethylene and ethylene oxide in air, and hydrocarbons in oxygen or in clean dry air.

The instrument works as an isothermal chromatograph. A sample enters the column through a metering valve, the components separate in the carrier gas stream and then reach the detector. The influence of the permanent gas matrix on the result is small. There are two models. The ta5000R has a reduction detector (RGD) with photometric detection of mercury vapour and measures hydrogen, carbon monoxide and unsaturated hydrocarbons. The ta5000F has a flame ionisation detector (FID) and measures carbon dioxide, methane and non-methane hydrocarbons.

Detection limits for the ta5000R are 3 ppb for H2 and CO with nitrogen or argon carrier gas, and 5 ppb for H2 with oxygen. For the ta5000F they are 4-7 ppb for CO2, 3-6 ppb for CH4 and 7-10 ppb for non-methane hydrocarbons, depending on the carrier gas. The standard range is 0-3 ppm for the ta5000R and 0-5 ppm for the ta5000F, with larger ranges optional. Accuracy for the ta5000R is ±3 ppb or ±10 % of reading, whichever is greater. Analysis takes 6-10 min, and response to 99 % takes 2 to 10 min. Display resolution is 0.1 ppb, and resolution through the communication ports is 0.01 ppb.

The instrument has its own sample conditioning system and a microprocessor that stores calibration parameters, processes data and controls a Sigma 4000 multipoint stream switch for sampling several points. The case mounts in a 19-inch rack and can be carried to site for surveys. Carrier gas inlet pressure is 4.8-6.1 bar with stability of ±2 %, and exhaust is preferably vented to atmosphere. Outputs include an optional 4-20 mA signal, an RS232 serial port for a PLC, COM ports 1-3 and a parallel printer port. The graphic display has a backlight. Power is 100-120 or 200-240 VAC, 50/60 Hz, operating temperature is 16-32 °C and mass is 15.9 kg.

Technical specifications

Typeisothermal gas chromatograph
Modelsta5000R (RGD), ta5000F (FID)
Components ta5000RH2, CO, unsaturated hydrocarbons
Components ta5000FCO2, CH4, non-methane hydrocarbons
Detection limit ta5000R3 ppb CO; 3 ppb H2
Detection limit ta5000F4-7 ppb CO2; 3-6 ppb CH4; 7-10 ppb NMHC
Range0-3 ppm (ta5000R); 0-5 ppm (ta5000F), larger ranges optional
Analysis time6-10 min
Response time2-10 min to 99%
Resolution0.1 ppb (display), 0.01 ppb (ports)
Inlet gas pressure4.8-6.1 bar
Outputs and ports4-20 mA (option), RS232, COM 1-3, LPT
Power100-120 VAC or 200-240 VAC, 50/60 Hz
Operating temperature16-32 °C
Dimensions18 x 43 x 67 cm (H x W x D)
Weight15.9 kg

Part numbers

Show all part numbers (11)

ta5000R, ta5000F, ta5000R-N2, ta5000R-Ar, ta5000R-He, ta5000R-O2, ta5000F-N2, ta5000F-Ar, ta5000F-He, ta5000F-O2, ta5000F-H2

Request a price and lead time

Ta5000 isothermal gas chromatograph for trace impurities, RGD or FID detector, from 3 ppb. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How do the ta5000R and ta5000F differ?

The ta5000R, with a reduction detector, measures H2, CO and unsaturated hydrocarbons. The ta5000F, with a flame ionisation detector, measures CO2, CH4 and non-methane hydrocarbons.

Can one instrument monitor several sampling points?

Yes. The ta5000 connects to a Sigma 4000 multipoint stream switch, which the instrument's built-in microprocessor controls.

What is the hydrogen detection limit?

For the ta5000R it is 3 ppb with nitrogen or argon carrier gas, and 5 ppb with oxygen.