International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

STZ dual input HART temperature transmitter for safety systems, SIL 2/3, associated IS

The STZ is a programmable dual input smart HART temperature transmitter for safety instrumented systems. It accepts one or two RTD, thermocouple, ohm, millivolt or potentiometer inputs and gives 4-20 mA, loop powered at 12-42 Vdc.

Input
single or dual, programmable: RTD, thermocouple, ohms, mV, potentiometer
Output
4-20 mA, one analogue output
Power supply
12-42 Vdc, 2-wire, from the output loop
Protocol
HART

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Built for safety instrumented systems (SIS), the STZ is a SIL 2/3 capable dual input smart HART temperature transmitter. It configures quickly and easily for a single or dual input from a wide array of sensors and analogue devices in hazardous and nonhazardous areas.

The programmable input takes RTD, thermocouple, ohm, millivolt or potentiometer signals. The output is 4-20 mA, and the 2-wire unit is powered from the output loop at 12-42 Vdc. It has one analogue output and no integral display. Its function in a safety loop is temperature measurement.

The STZ/PRG/4-20mA/12-42DC/-AIS [DIN] version carries the -AIS option, which provides associated intrinsically-safe input connections. Hazardous-area certification is Associated Intrinsically-Safe, Non-Incendive/Div. 2, Zone 2. An IEC 61508 certificate is available, and the unit is RoHS compliant.

The housing mounts on DIN rail. Configuration is through PACTware with the communication DTMs, and the STZ Device DTM, the HART DD and support for 375 and 475 handheld communicators are provided.

Technical specifications

Inputsingle or dual, programmable: RTD, thermocouple, ohms, mV, potentiometer
Output4-20 mA, one analogue output
Power supply12-42 Vdc, 2-wire, from the output loop
ProtocolHART
Option-AIS, associated IS input connections
Functional safetySIL 2/3, IEC 61508 certificate
Hazardous areasAssociated Intrinsically-Safe, Non-Incendive/Div. 2, Zone 2
Displaynone
HousingDIN rail

Part numbers

Show all part numbers (1)

STZ/PRG/4-20mA/12-42DC/-AIS [DIN]

How it compares with similar models

ParameterSTZ dual input HART temperature transmitter for safety systems, SIL 2/3, associated ISSSX 2-wire HART safety isolator, SIL 3, 4-20 mASTZ functional safety dual input HART temperature transmitter, SIL 2/3, 4-20mA, 12-42DCSTZ associated IS dual input HART temperature transmitter (-AIS), SIL 2/3, 4-20mA
Inputsingle or dual, programmable: RTD, thermocouple, ohms, mV, potentiometer4-20 mAOne or two sensors: RTD (14 types), T/C (9 types), mV, ohms, potentiometerOne or two sensors: RTD, T/C, mV, ohms, potentiometer
Output4-20 mA, one analogue output4-20 mA, one analogue output4-20mA with HART (HART 7)4-20mA with HART
Functional safetySIL 2/3, IEC 61508 certificateIEC 61508:2010, SIL 3 in monitor mode, SIL 2 in single useSystematic integrity up to SIL 3, random integrity up to SIL 2SIL 2/3 capable
HousingDIN railmetal, 35 mm Top Hat or 32 mm G-type DIN railHockey puck housing with DIN rail clipDIN rail mount, DIN rail enclosure

Request a price and lead time

STZ dual input HART temperature transmitter for safety systems, SIL 2/3, associated IS. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which sensors can the STZ read?

One or two inputs from RTDs, thermocouples, ohm signals, millivolt signals or a potentiometer.

What does the -AIS option mean?

The input connections are associated intrinsically-safe.

What supply and output does the STZ use?

It is 2-wire powered from the output loop at 12-42 Vdc and gives 4-20 mA with HART.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides