STZ dual input HART temperature transmitter for safety systems, SIL 2/3, associated IS
The STZ is a programmable dual input smart HART temperature transmitter for safety instrumented systems. It accepts one or two RTD, thermocouple, ohm, millivolt or potentiometer inputs and gives 4-20 mA, loop powered at 12-42 Vdc.
- Input
- single or dual, programmable: RTD, thermocouple, ohms, mV, potentiometer
- Output
- 4-20 mA, one analogue output
- Power supply
- 12-42 Vdc, 2-wire, from the output loop
- Protocol
- HART
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Built for safety instrumented systems (SIS), the STZ is a SIL 2/3 capable dual input smart HART temperature transmitter. It configures quickly and easily for a single or dual input from a wide array of sensors and analogue devices in hazardous and nonhazardous areas.
The programmable input takes RTD, thermocouple, ohm, millivolt or potentiometer signals. The output is 4-20 mA, and the 2-wire unit is powered from the output loop at 12-42 Vdc. It has one analogue output and no integral display. Its function in a safety loop is temperature measurement.
The STZ/PRG/4-20mA/12-42DC/-AIS [DIN] version carries the -AIS option, which provides associated intrinsically-safe input connections. Hazardous-area certification is Associated Intrinsically-Safe, Non-Incendive/Div. 2, Zone 2. An IEC 61508 certificate is available, and the unit is RoHS compliant.
The housing mounts on DIN rail. Configuration is through PACTware with the communication DTMs, and the STZ Device DTM, the HART DD and support for 375 and 475 handheld communicators are provided.
Technical specifications
| Input | single or dual, programmable: RTD, thermocouple, ohms, mV, potentiometer |
|---|---|
| Output | 4-20 mA, one analogue output |
| Power supply | 12-42 Vdc, 2-wire, from the output loop |
| Protocol | HART |
| Option | -AIS, associated IS input connections |
| Functional safety | SIL 2/3, IEC 61508 certificate |
| Hazardous areas | Associated Intrinsically-Safe, Non-Incendive/Div. 2, Zone 2 |
| Display | none |
| Housing | DIN rail |
Part numbers
Show all part numbers (1)
STZ/PRG/4-20mA/12-42DC/-AIS [DIN]
How it compares with similar models
| Parameter | STZ dual input HART temperature transmitter for safety systems, SIL 2/3, associated IS | SSX 2-wire HART safety isolator, SIL 3, 4-20 mA | STZ functional safety dual input HART temperature transmitter, SIL 2/3, 4-20mA, 12-42DC | STZ associated IS dual input HART temperature transmitter (-AIS), SIL 2/3, 4-20mA |
|---|---|---|---|---|
| Input | single or dual, programmable: RTD, thermocouple, ohms, mV, potentiometer | 4-20 mA | One or two sensors: RTD (14 types), T/C (9 types), mV, ohms, potentiometer | One or two sensors: RTD, T/C, mV, ohms, potentiometer |
| Output | 4-20 mA, one analogue output | 4-20 mA, one analogue output | 4-20mA with HART (HART 7) | 4-20mA with HART |
| Functional safety | SIL 2/3, IEC 61508 certificate | IEC 61508:2010, SIL 3 in monitor mode, SIL 2 in single use | Systematic integrity up to SIL 3, random integrity up to SIL 2 | SIL 2/3 capable |
| Housing | DIN rail | metal, 35 mm Top Hat or 32 mm G-type DIN rail | Hockey puck housing with DIN rail clip | DIN rail mount, DIN rail enclosure |
Request a price and lead time
STZ dual input HART temperature transmitter for safety systems, SIL 2/3, associated IS. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which sensors can the STZ read?
One or two inputs from RTDs, thermocouples, ohm signals, millivolt signals or a potentiometer.
What does the -AIS option mean?
The input connections are associated intrinsically-safe.
What supply and output does the STZ use?
It is 2-wire powered from the output loop at 12-42 Vdc and gives 4-20 mA with HART.