STZ associated IS dual input HART temperature transmitter (-AIS), SIL 2/3, 4-20mA
The STZ with the -AIS option is SIL 2/3 capable and has associated intrinsically safe input connections. It takes one or two sensors, gives 4-20mA with HART and is loop powered at 12-42DC.
- Type
- Functional safety dual input associated IS HART temperature transmitter
- Input
- One or two sensors: RTD, T/C, mV, ohms, potentiometer
- Output
- 4-20mA with HART
- Power
- 12-42DC, 2-wire, loop powered
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The STZ is a SIL 2/3 capable temperature transmitter designed for Safety Instrumented Systems (SIS). It configures quickly and accepts a single or dual input from sensors and analogue devices located in hazardous and non-hazardous areas. The input is programmable for an RTD, thermocouple (T/C), millivolt source, ohms or a potentiometer.
The -AIS option provides associated intrinsically safe input connections, which makes this version an associated apparatus. For hazardous areas the rating is Non-Incendive/Div. 2, Zone 2, Associated Intrinsically-Safe.
The output is 4-20mA with HART digital communication. The transmitter is a 2-wire device powered from the loop at 12-42DC. It is fully isolated and built in a DIN rail enclosure, with no integral display and no alarm or relay output.
Configuration is from a PC over a USB cable or over HART. There is no enhanced RFI/EMI immunity and no 2 inch pipe mount bracket. The unit is RoHS compliant. In the model code STZ/PRG/4-20mA/12-42DC/-AIS [DIN], PRG stands for the programmable input, 4-20mA for the output, 12-42DC for the supply and [DIN] for the DIN rail housing.
Technical specifications
| Type | Functional safety dual input associated IS HART temperature transmitter |
|---|---|
| Input | One or two sensors: RTD, T/C, mV, ohms, potentiometer |
| Output | 4-20mA with HART |
| Power | 12-42DC, 2-wire, loop powered |
| Functional safety | SIL 2/3 capable |
| Option -AIS | Associated IS input connections |
| Intrinsically safe input connections | Yes |
| Housing | DIN rail mount, DIN rail enclosure |
| Integral display | No |
| Alarm / relay output | No |
| Configuration | PC, USB cable, HART |
| Isolation | Fully isolated |
| Hazardous area certifications | Non-Incendive/Div. 2, Zone 2, Associated Intrinsically-Safe |
| For use in SIS | Yes |
| RoHS | Yes |
Part numbers
Show all part numbers (1)
STZ/PRG/4-20mA/12-42DC/-AIS [DIN]
How it compares with similar models
| Parameter | STZ associated IS dual input HART temperature transmitter (-AIS), SIL 2/3, 4-20mA | THZ3 associated IS dual input HART temperature transmitter (-AIS), 4-20mA, DIN rail | STZ functional safety dual input HART temperature transmitter, SIL 2/3, 4-20mA, 12-42DC | THZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DC |
|---|---|---|---|---|
| Type | Functional safety dual input associated IS HART temperature transmitter | Dual input associated IS HART temperature transmitter | Functional safety dual input smart HART temperature transmitter | Dual input HART temperature transmitter for DIN rail mounting |
| Input | One or two sensors: RTD, T/C, mV, ohms, potentiometer | Dual sensor, programmable: RTD, T/C, mV, ohms, potentiometer | One or two sensors: RTD (14 types), T/C (9 types), mV, ohms, potentiometer | Dual sensor, programmable: RTD, T/C, mV, ohms, potentiometer |
| Output | 4-20mA with HART | 4-20mA with HART | 4-20mA with HART (HART 7) | 4-20mA, isolated, linear, with HART |
| Intrinsically safe input connections | Yes | Yes | — | No |
| Housing | DIN rail mount, DIN rail enclosure | DIN rail mount, DIN rail enclosure | Hockey puck housing with DIN rail clip | DIN rail mount, DIN rail enclosure |
| Integral display | No | No | Yes | No |
Request a price and lead time
STZ associated IS dual input HART temperature transmitter (-AIS), SIL 2/3, 4-20mA. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What is the STZ -AIS designed for?
Safety Instrumented Systems (SIS). The transmitter is SIL 2/3 capable.
What does the -AIS option mean?
Associated intrinsically safe input connections. For hazardous areas the rating is Non-Incendive/Div. 2, Zone 2, Associated Intrinsically-Safe.
How is the STZ -AIS configured?
From a PC over a USB cable or over HART. There is no integral display.
Similar equipment from other manufacturers