STZ functional safety dual input HART temperature transmitter, SIL 2/3, 4-20mA, 12-42DC

The STZ is a SIL 2/3 capable temperature transmitter for safety instrumented systems. It takes one or two sensor inputs, outputs 4-20mA with HART and is loop powered at 12-42DC.

Type
Functional safety dual input smart HART temperature transmitter
Input
One or two sensors: RTD (14 types), T/C (9 types), mV, ohms, potentiometer
Output
4-20mA with HART (HART 7)
Power
12-42DC, 2-wire, loop powered

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The STZ belongs to the FS functional safety series and is built for Safety Instrumented Systems (SIS). It accepts a single or dual input from sensors and analogue devices in hazardous and non-hazardous areas: 14 RTD types, 9 thermocouple types, resistance and potentiometer devices and direct millivolt sources.

The device is certified by exida to IEC 61508:2010, with systematic integrity up to SIL 3 and random integrity up to SIL 2. A single STZ is approved for SIS use up to SIL 2, and in a redundant architecture (1oo2, 2oo3 and so on) up to SIL 3. Certified FMEDA data is available on request.

This 2-wire, loop powered transmitter gives an isolated, linear 4-20mA output proportional to the input, ready for HART and non-HART safety systems, DCS, PLC and SCADA. It is HART 7 compliant, with exception-based reporting and dynamic variable mapping. HART access can be set to read only or off, so the configuration cannot be changed by accident while the safety function is running.

With two sensors the user gets backup and failover, average and differential measurement, and low or high select. Diagnostics cover sensor drift and corrosion detection, smart range alarms, a high-availability option and input simulation.

Input-to-output analogue accuracy reaches ±0.014°C (±0.025°F). Input resolution is 20-bit, giving digital accuracy of ±0.1°C (±0.18°F) with all Pt RTDs and up to ±0.05°C (±0.09°F) for Pt1000. The best figures apply to a 4-wire, 1000 ohm platinum RTD with a span of 100°F (50°F minimum), calibrated in a sensor-matching bath.

Mounting choices are field enclosures with display, compact connection heads without display and a high-density DIN-style housing. The STZ-DIN model with the -AIS option connects sensors in hazardous locations directly, without an intrinsically safe barrier, and has blue terminals. Setup is by a HART handheld, a HART host, a PC over USB or an FDT host such as PACTware using the DTM.

Technical specifications

TypeFunctional safety dual input smart HART temperature transmitter
InputOne or two sensors: RTD (14 types), T/C (9 types), mV, ohms, potentiometer
Output4-20mA with HART (HART 7)
Power12-42DC, 2-wire, loop powered
Functional safetySystematic integrity up to SIL 3, random integrity up to SIL 2
StandardIEC 61508:2010
Input-to-output analogue accuracyUp to ±0.014°C (±0.025°F)
Digital accuracy±0.1°C (±0.18°F) with Pt RTDs, up to ±0.05°C (±0.09°F) for Pt1000
Input resolution20-bit
HousingHockey puck housing with DIN rail clip
Integral displayYes
Alarm / relay outputNo
ConfigurationPC, USB cable, HART
IsolationFully isolated
Hazardous area certificationsNon-Incendive/Div. 2, Zone 2
For use in SISYes
RoHSYes

Part numbers

Show all part numbers (4)

STZ/PRG/4-20mA/12-42DC [DN], STZ/PRG/4-20MA/12-30DC/[HP], STZ/PRG/4-20MA/12-30DC/[HPP], STZ/PRG/4-20MA/12-30DC/[DIN]

How it compares with similar models

ParameterSTZ functional safety dual input HART temperature transmitter, SIL 2/3, 4-20mA, 12-42DCTDZ3 dual input HART temperature transmitter, 4-20mA, 12-42DC loop poweredSTZ associated IS dual input HART temperature transmitter (-AIS), SIL 2/3, 4-20mATHZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DC
TypeFunctional safety dual input smart HART temperature transmitterDual input smart HART temperature transmitterFunctional safety dual input associated IS HART temperature transmitterDual input HART temperature transmitter for DIN rail mounting
InputOne or two sensors: RTD (14 types), T/C (9 types), mV, ohms, potentiometerDual sensor, programmable: RTD, T/C, mV, ohms, potentiometerOne or two sensors: RTD, T/C, mV, ohms, potentiometerDual sensor, programmable: RTD, T/C, mV, ohms, potentiometer
Output4-20mA with HART (HART 7)4-20mA with HART4-20mA with HART4-20mA, isolated, linear, with HART
HousingHockey puck housing with DIN rail clipHockey puck housing with DIN rail clipDIN rail mount, DIN rail enclosureDIN rail mount, DIN rail enclosure
Integral displayYesYesNoNo
Hazardous area certificationsNon-Incendive/Div. 2, Zone 2Non-Incendive/Div. 2, Zone 2Non-Incendive/Div. 2, Zone 2, Associated Intrinsically-SafeNon-Incendive/Div. 2, Zone 2

Request a price and lead time

STZ functional safety dual input HART temperature transmitter, SIL 2/3, 4-20mA, 12-42DC. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What SIL can the STZ be used for?

A single STZ is approved for SIS use up to SIL 2, and in a redundant architecture (1oo2, 2oo3 and so on) up to SIL 3. It is certified by exida to IEC 61508:2010.

What dual sensor modes are available?

Backup and failover, average, differential, and low or high select. Sensor drift and corrosion detection are included.

How can the settings be protected while the loop is in service?

HART access can be set to read only or switched off. This prevents accidental or unauthorised reconfiguration while the safety function is working.