THZ3 associated IS dual input HART temperature transmitter (-AIS), 4-20mA, DIN rail
The THZ3 with the -AIS option is an associated apparatus. It is installed in a non-hazardous or Class I Division 2/Zone 2 area and connects directly to sensors in Class I Div 1/Zone 0/1 locations.
- Type
- Dual input associated IS HART temperature transmitter
- Input
- Dual sensor, programmable: RTD, T/C, mV, ohms, potentiometer
- Output
- 4-20mA with HART
- Power
- 12-42DC, 2-wire, loop powered
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The THZ3 with the -AIS option is an associated apparatus. It is suitable for installation in non-hazardous or Class I Division 2/Zone 2 areas, with direct connection to temperature sensors located in Class I Div 1/Zone 0/1 locations. The -AIS option provides associated intrinsically safe input connections.
The transmitter accepts a direct signal from sensors and analogue devices in hazardous and non-hazardous areas. The input is programmable for an RTD, thermocouple (T/C), millivolt source, ohms or a potentiometer. The two input sensors are individually selectable and programmable.
Features include backup and fail-over protection, average and differential measurement, dynamic variable mapping and high-select and low-select abilities. The output is 4-20mA with HART, and the unit is a 2-wire device powered from the loop at 12-42DC.
The housing is a DIN rail enclosure with no integral display. Configuration is from a PC over a USB cable or over HART. The unit is fully isolated. The hazardous area rating is Non-Incendive/Div. 2, Zone 2, Associated Intrinsically-Safe. There is no alarm or relay output and no enhanced RFI/EMI immunity, and the transmitter is not for use in SIS. It is RoHS compliant.
Technical specifications
| Type | Dual input associated IS HART temperature transmitter |
|---|---|
| Input | Dual sensor, programmable: RTD, T/C, mV, ohms, potentiometer |
| Output | 4-20mA with HART |
| Power | 12-42DC, 2-wire, loop powered |
| Option -AIS | Associated IS input connections |
| Intrinsically safe input connections | Yes |
| Housing | DIN rail mount, DIN rail enclosure |
| Integral display | No |
| Alarm / relay output | No |
| Configuration | PC, USB cable, HART |
| Isolation | Fully isolated |
| Hazardous area certifications | Non-Incendive/Div. 2, Zone 2, Associated Intrinsically-Safe |
| For use in SIS | No |
| RoHS | Yes |
Part numbers
Show all part numbers (1)
THZ3/PRG/4-20mA/12-42DC/-AIS [DIN]
How it compares with similar models
| Parameter | THZ3 associated IS dual input HART temperature transmitter (-AIS), 4-20mA, DIN rail | STZ associated IS dual input HART temperature transmitter (-AIS), SIL 2/3, 4-20mA | THZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DC | TDZ3 dual input HART temperature transmitter, 4-20mA, 12-42DC loop powered |
|---|---|---|---|---|
| Type | Dual input associated IS HART temperature transmitter | Functional safety dual input associated IS HART temperature transmitter | Dual input HART temperature transmitter for DIN rail mounting | Dual input smart HART temperature transmitter |
| Input | Dual sensor, programmable: RTD, T/C, mV, ohms, potentiometer | One or two sensors: RTD, T/C, mV, ohms, potentiometer | Dual sensor, programmable: RTD, T/C, mV, ohms, potentiometer | Dual sensor, programmable: RTD, T/C, mV, ohms, potentiometer |
| Output | 4-20mA with HART | 4-20mA with HART | 4-20mA, isolated, linear, with HART | 4-20mA with HART |
| Intrinsically safe input connections | Yes | Yes | No | No |
| Housing | DIN rail mount, DIN rail enclosure | DIN rail mount, DIN rail enclosure | DIN rail mount, DIN rail enclosure | Hockey puck housing with DIN rail clip |
| Integral display | No | No | No | Yes |
Request a price and lead time
THZ3 associated IS dual input HART temperature transmitter (-AIS), 4-20mA, DIN rail. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Where can the THZ3 with the -AIS option be installed?
In non-hazardous or Class I Division 2/Zone 2 areas. Sensors in Class I Div 1/Zone 0/1 locations connect directly.
What dual sensor functions are available?
Backup and fail-over protection, average and differential measurement, dynamic variable mapping, and high-select and low-select.
How is the transmitter configured?
From a PC over a USB cable or over HART. There is no integral display.