TMZ MODBUS temperature transmitter and signal converter for RTD, T/C, mV, ohms and potentiometer, 24DC

The TMZ accepts a direct signal from RTD, T/C, ohms, mV or potentiometer sensors and sends it over MODBUS RTU. PC-programmable, 24DC supply, DIN rail housing, fully isolated.

Type
PC-programmable MODBUS temperature transmitter and signal converter
Input
One input: RTD, T/C, mV, ohms, potentiometer
Output
MODBUS RTU
Power
24DC, 4-wire, line/mains powered

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TMZ is a PC-programmable MODBUS temperature transmitter and signal converter. It accepts a direct signal input from sensors and analogue devices, RTD, T/C, ohms, mV or potentiometer, and passes the result on over MODBUS RTU.

The unit is 4-wire and line/mains powered at 24DC. It has a single input, set for the sensor type in use. Configuration is from a PC over a USB cable.

The housing is for DIN rail mounting and the unit is fully isolated. There is no integral display and no alarm or relay output, no intrinsically safe input connections, no enhanced RFI/EMI immunity and no 2 inch pipe mount bracket. It is not for use in SIS. It is RoHS compliant.

Input types: RTD means a resistance temperature detector, T/C a thermocouple, ohms a resistance measurement, mV a millivolt source and potentiometer a position sensor. The 24DC supply comes from the line/mains, so no separate current loop is needed. The MODBUS RTU output suits connection to MODBUS-based monitoring and control systems.

In the model code TMZ/TPRG/MB/24DC, TPRG stands for the programmable input for RTD, T/C, ohms, mV or potentiometer, MB for the MODBUS RTU output and 24DC for the supply.

Technical specifications

TypePC-programmable MODBUS temperature transmitter and signal converter
InputOne input: RTD, T/C, mV, ohms, potentiometer
OutputMODBUS RTU
Power24DC, 4-wire, line/mains powered
HousingDIN rail mount, DIN rail enclosure
ConfigurationPC, USB cable
IsolationFully isolated
Integral displayNo
Alarm / relay outputNo
Intrinsically safe input connectionsNo
For use in SISNo
RoHSYes

Part numbers

Show all part numbers (1)

TMZ/TPRG/MB/24DC

How it compares with similar models

ParameterTMZ MODBUS temperature transmitter and signal converter for RTD, T/C, mV, ohms and potentiometer, 24DCTMZ MODBUS converter for current and voltage signals, 0-50mA and 0-10V, 24DCHSM humidity and temperature sensing module, RTD and RH inputs, NEMA 4X, IP66TRY PC-programmable isolated temperature transmitter, 4-20mA, 10-42DC, DIN rail
TypePC-programmable MODBUS temperature transmitter and signal converterPC-programmable MODBUS signal converter for current and voltageHumidity and temperature sensing module (part of the HTZ)PC-programmable isolated temperature transmitter
InputOne input: RTD, T/C, mV, ohms, potentiometerProgrammable, any range within 0-50mA or 0-10VOne temperature (RTD) input and one relative humidity input—
OutputMODBUS RTUMODBUS RTUSignal to the HDM display module4-20mA, linear, scalable, 4-20mA only
Power24DC, 4-wire, line/mains powered24DC, 4-wire, line/mains powered2-wire, loop power supplied by the HDM module10-42DC, 2-wire, loop powered
HousingDIN rail mount, DIN rail enclosureDIN rail mount, DIN rail enclosureSurface or pipe mount enclosure, NEMA 4X, IP66DIN rail mount, DIN rail enclosure

Request a price and lead time

TMZ MODBUS temperature transmitter and signal converter for RTD, T/C, mV, ohms and potentiometer, 24DC. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which sensors can be connected to the TMZ?

RTD, T/C, mV, ohms or potentiometer. The input type is set from a PC.

What output protocol does the TMZ use?

MODBUS RTU.

What supply does the TMZ need?

24DC. The unit is 4-wire and line/mains powered.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides