International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

HSM humidity and temperature sensing module, RTD and RH inputs, NEMA 4X, IP66

The HSM picks up temperature (RTD) and relative humidity at the measurement site and sends them to the HDM display module. NEMA 4X (IP66) enclosure for surface or pipe mounting, loop powered.

Type
Humidity and temperature sensing module (part of the HTZ)
Input
One temperature (RTD) input and one relative humidity input
Output
Signal to the HDM display module
Power
2-wire, loop power supplied by the HDM module

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The HSM is the sensing module of the HTZ smart HART humidity and temperature transmitter. It is designed to mount on a surface at the measurement site. Its temperature and humidity probes collect real-time ambient conditions and transmit them to the HDM display module, the other half of the HTZ.

The module has one temperature (RTD) input and one relative humidity input. The output signal goes to the HDM. The HSM is a 2-wire device and takes its loop power from the HDM, so no separate supply is required.

Probe length for the RTD and RH probes is set by the -CL option. The order numbers include -CL6, -CL12, -CL18 and -CL3.75, plus the extra designations FLEX120, VTB and VTRH. There are 25 versions in all, and each code ends with a bracketed suffix such as [LH3P], [LH3Z] or [LH4P].

The enclosure for surface or pipe mounting is rated NEMA 4X, IP66. It comes with 2 inch pipe-mount hardware and a standard (NPT) conduit connection. There is no integral display, since readings are shown on the HDM. The unit is fully isolated and is configured from a PC over a USB cable.

There are no intrinsically safe input connections, no alarm or relay output and no enhanced RFI/EMI immunity. The module is not for use in SIS and is RoHS compliant.

Technical specifications

TypeHumidity and temperature sensing module (part of the HTZ)
InputOne temperature (RTD) input and one relative humidity input
OutputSignal to the HDM display module
Power2-wire, loop power supplied by the HDM module
RTD and RH probe lengthOption -CL6, -CL12, -CL18, -CL3.75
HousingSurface or pipe mount enclosure, NEMA 4X, IP66
2 inch pipe mount hardwareYes, included
Conduit connectionStandard (NPT)
Integral displayNo
ConfigurationPC, USB cable
IsolationFully isolated
Intrinsically safe input connectionsNo
Alarm / relay outputNo
For use in SISNo
RoHSYes

Part numbers

Show all part numbers (5)

HSM/PT-RH/HDM/HDM/-CL6 [LH3P], HSM/PT-RH/HDM/HDM/-CL6 [LH3Z], HSM/PT-RH/HDM/HDM/-CL12 [LH3P], HSM/PT-RH/HDM/HDM/-CL18 [LH3P], HSM/PT-RH/HDM/HDM/-CL3.75-FLEX120-VTB-VTRH [LH4P]

How it compares with similar models

ParameterHSM humidity and temperature sensing module, RTD and RH inputs, NEMA 4X, IP66HDM humidity and temperature display module, dual 4-20mA outputs, 12-42DC, IP66TMZ MODBUS temperature transmitter and signal converter for RTD, T/C, mV, ohms and potentiometer, 24DCTRY PC-programmable isolated temperature transmitter, 4-20mA, 10-42DC, DIN rail
TypeHumidity and temperature sensing module (part of the HTZ)Humidity and temperature display module (part of the HTZ)PC-programmable MODBUS temperature transmitter and signal converterPC-programmable isolated temperature transmitter
InputOne temperature (RTD) input and one relative humidity inputSignal from the HSM module: humidity, dew point, RTDOne input: RTD, T/C, mV, ohms, potentiometer—
OutputSignal to the HDM display moduleDual isolated, scalable 4-20mA outputs, user-selectable: relative humidity, temperature, dew pointMODBUS RTU4-20mA, linear, scalable, 4-20mA only
Power2-wire, loop power supplied by the HDM module12-42DC, 2-wire, loop powered24DC, 4-wire, line/mains powered10-42DC, 2-wire, loop powered
HousingSurface or pipe mount enclosure, NEMA 4X, IP66Surface or pipe mount enclosure, NEMA 4X, IP66DIN rail mount, DIN rail enclosureDIN rail mount, DIN rail enclosure
Integral displayNoYesNoNo

Request a price and lead time

HSM humidity and temperature sensing module, RTD and RH inputs, NEMA 4X, IP66. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How is the HSM connected to the HTZ?

Its output signal goes to the HDM display module, which also supplies the loop power for the HSM.

What does the -CL option in the order number set?

The length of the RTD and RH probes. The order numbers include -CL6, -CL12, -CL18 and -CL3.75.

What is the enclosure rating of the HSM?

NEMA 4X, IP66. The enclosure is for surface or pipe mounting and 2 inch pipe-mount hardware is included.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides