International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TDZ3 dual input HART temperature transmitter, 4-20mA, 12-42DC loop powered

The TDZ3 takes two sensor inputs (RTD, T/C, mV, ohms or potentiometer) and gives 4-20mA with HART. It is loop powered from 12-42DC and comes in a hockey puck housing with a DIN rail clip.

Type
Dual input smart HART temperature transmitter
Input
Dual sensor, programmable: RTD, T/C, mV, ohms, potentiometer
Output
4-20mA with HART
Power
12-42DC, 2-wire, loop powered

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TDZ3 is a smart temperature transmitter with two programmable inputs. It accepts a direct signal from sensors and analogue devices located in hazardous and non-hazardous areas. The input is set for an RTD, a thermocouple (T/C), a millivolt source, ohms or a potentiometer.

The output is 4-20mA carrying HART digital communication. The unit is a 2-wire device powered from the output loop at 12-42DC, so no separate supply is needed.

The housing is of the hockey puck type with a DIN rail clip, and a DIN rail adapter is available for field mounted electronics. An integral display is fitted and the unit is fully isolated. Configuration is done from a PC over a USB cable or over HART. A DTM for PACTware and DD files for 375 and 475 handhelds, AMS and HART hosts are available.

In the model code TDZ3/PRG/4-20mA/12-42DC [DN], PRG stands for the programmable input, 4-20mA for the output and 12-42DC for the supply.

For hazardous areas the rating is Non-Incendive/Div. 2, Zone 2. There are no intrinsically safe input connections, no alarm or relay output, no enhanced RFI/EMI immunity and no 2 inch pipe mount bracket. The transmitter is not intended for use in Safety Instrumented Systems (SIS). It is RoHS compliant.

Technical specifications

TypeDual input smart HART temperature transmitter
InputDual sensor, programmable: RTD, T/C, mV, ohms, potentiometer
Output4-20mA with HART
Power12-42DC, 2-wire, loop powered
HousingHockey puck housing with DIN rail clip
MountingDIN rail adapter for field mounted electronics
Integral displayYes
Alarm / relay outputNo
Intrinsically safe input connectionsNo
ConfigurationPC, USB cable, HART
IsolationFully isolated
Enhanced RFI/EMI immunityNo
2 inch pipe mount bracketNo
Hazardous area certificationsNon-Incendive/Div. 2, Zone 2
For use in SISNo
RoHSYes

Part numbers

Show all part numbers (1)

TDZ3/PRG/4-20mA/12-42DC [DN]

How it compares with similar models

ParameterTDZ3 dual input HART temperature transmitter, 4-20mA, 12-42DC loop poweredTHZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DCTHZ3 associated IS dual input HART temperature transmitter (-AIS), 4-20mA, DIN railSTZ functional safety dual input HART temperature transmitter, SIL 2/3, 4-20mA, 12-42DC
TypeDual input smart HART temperature transmitterDual input HART temperature transmitter for DIN rail mountingDual input associated IS HART temperature transmitterFunctional safety dual input smart HART temperature transmitter
InputDual sensor, programmable: RTD, T/C, mV, ohms, potentiometerDual sensor, programmable: RTD, T/C, mV, ohms, potentiometerDual sensor, programmable: RTD, T/C, mV, ohms, potentiometerOne or two sensors: RTD (14 types), T/C (9 types), mV, ohms, potentiometer
Output4-20mA with HART4-20mA, isolated, linear, with HART4-20mA with HART4-20mA with HART (HART 7)
HousingHockey puck housing with DIN rail clipDIN rail mount, DIN rail enclosureDIN rail mount, DIN rail enclosureHockey puck housing with DIN rail clip
Integral displayYesNoNoYes
Intrinsically safe input connectionsNoNoYes—

Request a price and lead time

TDZ3 dual input HART temperature transmitter, 4-20mA, 12-42DC loop powered. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which sensors can be connected to the TDZ3?

The dual sensor input is programmable for RTD, T/C, mV, ohms or potentiometer. The type is set from a PC over USB or over HART.

Does the TDZ3 need a separate power supply?

No, it is a 2-wire transmitter powered from the output loop at 12-42DC.

Can the TDZ3 be used in SIS loops?

No, the TDZ3 is not intended for use in Safety Instrumented Systems (SIS). For hazardous areas the rating is Non-Incendive/Div. 2, Zone 2.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides