THZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DC

The THZ3 accepts two sensors and gives an isolated, linear 4-20mA output with HART. It is a 2-wire, loop powered unit at 12-42DC in a DIN rail enclosure, rated Non-Incendive/Div. 2, Zone 2.

Type
Dual input HART temperature transmitter for DIN rail mounting
Input
Dual sensor, programmable: RTD, T/C, mV, ohms, potentiometer
Output
4-20mA, isolated, linear, with HART
Power
12-42DC, 2-wire, loop powered

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The THZ3 is a loop powered, 2-wire HART temperature transmitter. It accepts a direct signal input from sensors and analogue devices located in hazardous and non-hazardous areas. The input is programmed for an RTD, thermocouple (T/C), millivolt source, ohms or a potentiometer.

The two input sensors are individually selectable and programmable, which gives more control over temperature measurements. The 4-20mA output is isolated and linear, and the supply is 12-42DC. The transmitter can be interrogated at any time from anywhere on the 4-20mA loop.

Setup is from a HART host, a communicator or an FDT-compliant host or program, and also from a PC over a USB cable. This version is built in a DIN rail enclosure and has no integral display.

For hazardous areas the rating is Non-Incendive/Div. 2, Zone 2. There are no intrinsically safe input connections, no alarm or relay output, no enhanced RFI/EMI immunity and no 2 inch pipe mount bracket. The transmitter is not for use in SIS. It is RoHS compliant.

The series is offered in 24 versions. The suffix [DIN] marks the DIN rail housing, and there are also the codes [HPP], [HPPDN], [LH1NX], [LH2NS] and others.

Technical specifications

TypeDual input HART temperature transmitter for DIN rail mounting
InputDual sensor, programmable: RTD, T/C, mV, ohms, potentiometer
Output4-20mA, isolated, linear, with HART
Power12-42DC, 2-wire, loop powered
HousingDIN rail mount, DIN rail enclosure
Integral displayNo
Alarm / relay outputNo
Intrinsically safe input connectionsNo
ConfigurationPC, USB cable, HART
IsolationFully isolated
Enhanced RFI/EMI immunityNo
Hazardous area certificationsNon-Incendive/Div. 2, Zone 2
For use in SISNo
RoHSYes

Part numbers

Show all part numbers (5)

THZ3/PRG/4-20mA/12-42DC [DIN], THZ3/PRG/4-20mA/12-42DC/-RF [DIN], THZ3/PRG/4-20mA/12-42DC [HPP], THZ3/PRG/4-20mA/12-42DC [HPPDN], THZ3/PRG/4-20mA/12-30DC [HPP]

How it compares with similar models

ParameterTHZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DCTDZ3 dual input HART temperature transmitter, 4-20mA, 12-42DC loop poweredTHZ3 associated IS dual input HART temperature transmitter (-AIS), 4-20mA, DIN railSTZ associated IS dual input HART temperature transmitter (-AIS), SIL 2/3, 4-20mA
TypeDual input HART temperature transmitter for DIN rail mountingDual input smart HART temperature transmitterDual input associated IS HART temperature transmitterFunctional safety dual input associated IS HART temperature transmitter
InputDual sensor, programmable: RTD, T/C, mV, ohms, potentiometerDual sensor, programmable: RTD, T/C, mV, ohms, potentiometerDual sensor, programmable: RTD, T/C, mV, ohms, potentiometerOne or two sensors: RTD, T/C, mV, ohms, potentiometer
Output4-20mA, isolated, linear, with HART4-20mA with HART4-20mA with HART4-20mA with HART
HousingDIN rail mount, DIN rail enclosureHockey puck housing with DIN rail clipDIN rail mount, DIN rail enclosureDIN rail mount, DIN rail enclosure
Integral displayNoYesNoNo
Intrinsically safe input connectionsNoNoYesYes

Request a price and lead time

THZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DC. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which input signals does the THZ3 accept?

Two programmable inputs for RTD, T/C, mV, ohms or potentiometer. Each sensor is selected and programmed individually.

How is the THZ3 configured?

From a HART host, a communicator or an FDT-compliant host or program, and also from a PC over a USB cable.

Does this version have intrinsically safe inputs?

No, there are no intrinsically safe input connections. For hazardous areas the rating is Non-Incendive/Div. 2, Zone 2.