TMZ MODBUS temperature transmitter and signal converter, dual universal input, RS-485, 24DC

The TMZ dual input model takes current, voltage, RTD, thermocouple, mV, potentiometer or resistance signals and converts them to MODBUS RTU (RS-485). Up to 32 units share one link without repeaters.

Type
PC-programmable MODBUS temperature transmitter and signal converter with dual universal input
Input
Two inputs, each: current, voltage, RTD, T/C, mV, ohms, potentiometer
Output
MODBUS RTU (RS-485)
Power
24DC, 4-wire, line/mains powered

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The Dual Universal Input (2PRG) model of the TMZ accepts two inputs, and each input can be configured for current, voltage, RTD, thermocouple, mV, potentiometer or resistance. This doubles the monitoring capability of a single unit. The inputs are converted to the standard MODBUS RTU (RS-485) protocol, ready for direct interface with MODBUS-based monitoring and control systems.

The unit is 4-wire and line/mains powered at 24DC. Up to 32 TMZs can be multidropped without repeaters onto a single low-cost link such as a twisted wire pair, so there is no need to run a dedicated wire for each signal. This cuts installation, cable, conduit, connection and wire tray costs. The TMZ can share a data link with standard MODBUS RTU devices, and any combination of TMZ configurations may be used in the same system.

Input resolution is 20-bit, giving accuracy of ±0.1°C (±0.18°F) with all platinum RTDs, or ±0.01% of maximum span with current and voltage inputs. The measurement reaches the control system as a digital signal, so the output error of a traditional analogue transmitter is eliminated. Up to 5 years are allowed between scheduled calibrations. Isolation and RFI/EMI protection reduce the effects of ground loops, plant noise, and radio frequency and electromagnetic interference.

All parameters are set on a single screen of the Windows software: input type and range, input trimming, MODBUS parameters, T/C reference junction compensation and standard or custom linearisation curves. The TMZ can be trimmed with two data points within the selected range, which concentrates accuracy on a critical segment. It is housed for DIN rail with no display, is CE conformant to EMC Directive 2014/30/EU, EN 61326, and is RoHS compliant. It is not for use in SIS.

Technical specifications

TypePC-programmable MODBUS temperature transmitter and signal converter with dual universal input
InputTwo inputs, each: current, voltage, RTD, T/C, mV, ohms, potentiometer
OutputMODBUS RTU (RS-485)
Power24DC, 4-wire, line/mains powered
HousingDIN rail mount, DIN rail enclosure
Units per linkUp to 32 TMZs without repeaters
Input resolution20-bit
Accuracy±0.1°C (±0.18°F) with all platinum RTDs, ±0.01% of maximum span with current and voltage
StabilityUp to 5 years between scheduled calibrations
ConfigurationPC, USB cable
IsolationFully isolated
Integral displayNo
Intrinsically safe input connectionsNo
For use in SISNo
ConformityCE: EMC Directive 2014/30/EU, EN 61326; RoHS

Part numbers

Show all part numbers (1)

TMZ/2PRG/MB/24DC

How it compares with similar models

ParameterTMZ MODBUS temperature transmitter and signal converter, dual universal input, RS-485, 24DCTMZ MODBUS temperature transmitter and signal converter for RTD, T/C, mV, ohms and potentiometer, 24DCTHZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DCTMZ MODBUS converter for current and voltage signals, 0-50mA and 0-10V, 24DC
TypePC-programmable MODBUS temperature transmitter and signal converter with dual universal inputPC-programmable MODBUS temperature transmitter and signal converterDual input HART temperature transmitter for DIN rail mountingPC-programmable MODBUS signal converter for current and voltage
InputTwo inputs, each: current, voltage, RTD, T/C, mV, ohms, potentiometerOne input: RTD, T/C, mV, ohms, potentiometerDual sensor, programmable: RTD, T/C, mV, ohms, potentiometerProgrammable, any range within 0-50mA or 0-10V
OutputMODBUS RTU (RS-485)MODBUS RTU4-20mA, isolated, linear, with HARTMODBUS RTU
Power24DC, 4-wire, line/mains powered24DC, 4-wire, line/mains powered12-42DC, 2-wire, loop powered24DC, 4-wire, line/mains powered
ConfigurationPC, USB cablePC, USB cablePC, USB cable, HARTPC, USB cable

Request a price and lead time

TMZ MODBUS temperature transmitter and signal converter, dual universal input, RS-485, 24DC. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which signals does the TMZ 2PRG accept?

Two inputs, each configurable for current, voltage, RTD, thermocouple, mV, potentiometer or resistance.

How many TMZs can share one link?

Up to 32 without repeaters, for example on one twisted wire pair, so no dedicated wire per signal is needed.

What measurement accuracy can be expected?

±0.1°C (±0.18°F) with all platinum RTDs and ±0.01% of maximum span with current and voltage inputs. Input resolution is 20-bit.