SPA2 programmable temperature transmitter and alarm trip, RTD, T/C, mV, ohms, 2 relays, analogue output

The SPA2 accepts RTD, T/C, mV, ohms or potentiometer input, has two independent alarm relays, an optional programmable analogue output (-AO) and a 5-digit display. Power is 21.6-375VDC or 90-260VAC.

Type
Programmable temperature transmitter and alarm trip
Input
RTD (23 types), T/C (9 types), mV, ohms, potentiometer
Alarm outputs
Two independent, individually configurable alarm relay outputs
Analogue output (option -AO)
Programmable, any range between 0-20mA and 0-10V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The SPA2 is a programmable limit alarm trip with a temperature input. It provides on/off control, warns of unwanted process conditions, alarms on rate-of-change and provides emergency shutdown. The input accepts 23 RTD types, 9 thermocouple types, resistance and potentiometer devices and direct millivolt sources.

The unit is 4-wire and line/mains powered. The universal supply is 21.6-375VDC or 90-260VAC, so there is no need to stock dozens of different alarm trips. Two independent, individually configurable alarm relay outputs operate when the monitored variable falls outside the user-set high and/or low limits, and can drive a warning light, annunciator, bell, pump, motor or shutdown system. Trip points, high alarm, low alarm, failsafe, non-failsafe, normally open and normally closed are all configurable.

Parameters are set with the front panel push buttons or the free Windows software: input type and range, input and output trimming, password protection, and high or low trip, out of band, rate of change or stuck input alarms. Input resolution is 20-bit and the interval between calibrations is up to 5 years. The large 5-digit backlit display shows menu prompts, the process variable, the output, or toggles between the two.

The -AO option adds a programmable analogue output in any range between 0-20mA and 0-10V, so alarm and transmitter functions sit at the same location. The metal, RFI resistant housing snaps onto 35mm (EN50022) Top Hat DIN rails. Isolation and RFI/EMI protection reduce the effects of ground loops. The rating is Non-Incendive/Div. 2, Zone 2, and the unit is CE conformant to Directives 2014/30/EU (EN 61326) and 2014/35/EU (EN 61010-1). It is not for use in SIS.

Technical specifications

TypeProgrammable temperature transmitter and alarm trip
InputRTD (23 types), T/C (9 types), mV, ohms, potentiometer
Alarm outputsTwo independent, individually configurable alarm relay outputs
Analogue output (option -AO)Programmable, any range between 0-20mA and 0-10V
Power21.6-375VDC or 90-260VAC
Power connection4-Wire 24DC/117VAC/230VAC line/mains powered
HousingDIN-style, 35mm (EN50022) Top Hat DIN rail
Display5-digit, backlit
Input resolution20-bit
StabilityUp to 5 years between scheduled calibrations
ConfigurationPC, USB cable, push buttons
IsolationFully isolated
Intrinsically safe input connectionsNo
Hazardous area certificationsNon-Incendive/Div. 2, Zone 2
For use in SISNo
RoHSYes

Part numbers

Show all part numbers (1)

SPA2/TPRG/2PRG/U/-AO [DIN]

How it compares with similar models

ParameterSPA2 programmable temperature transmitter and alarm trip, RTD, T/C, mV, ohms, 2 relays, analogue outputSPA2IS programmable temperature transmitter and alarm trip with intrinsically safe inputs, 2 relaysSPT site-programmable isolated temperature transmitter, T/C, RTD, ohms, mV, 4-20mA or 1-5VTHZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DC
TypeProgrammable temperature transmitter and alarm tripProgrammable temperature transmitter and alarm trip with intrinsically safe field connectionsSite-programmable isolated temperature transmitterDual input HART temperature transmitter for DIN rail mounting
InputRTD (23 types), T/C (9 types), mV, ohms, potentiometerRTD (23 types), T/C (9 types), mV, ohms, potentiometerT/C (all common ISA), 2-, 3- or 4-wire RTD, ohms, mVDual sensor, programmable: RTD, T/C, mV, ohms, potentiometer
Power21.6-375VDC or 90-260VAC21.6-125VDC or 90-260VAC22-300VDC or 90-260VAC, auto-sensing12-42DC, 2-wire, loop powered
HousingDIN-style, 35mm (EN50022) Top Hat DIN railDIN-style, 35mm (EN50022) Top Hat DIN railDIN-style, 32mm G-type and 35mm Top HatDIN rail mount, DIN rail enclosure
Display5-digit, backlit5-digit, backlitLCD, input in °C or °F—
StabilityUp to 5 years between scheduled calibrationsUp to 5 years between scheduled calibrations±0.1% of calibrated span max over six months—

Request a price and lead time

SPA2 programmable temperature transmitter and alarm trip, RTD, T/C, mV, ohms, 2 relays, analogue output. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which inputs does the SPA2 accept?

23 RTD types, 9 thermocouple types, mV, resistance and potentiometer devices. Input resolution is 20-bit.

Which alarm types can be set?

High or low trip, out of band, rate of change and stuck input. The relays are configurable as failsafe or non-failsafe, normally open or normally closed.

What does the -AO option add?

A programmable analogue output in any range between 0-20mA and 0-10V, so one unit serves as alarm trip and transmitter.