SPT site-programmable isolated temperature transmitter, T/C, RTD, ohms, mV, 4-20mA or 1-5V
The SPT accepts T/C, RTD, millivolt or ohms input and gives an isolated, process-ready 4-20mA or 1-5V output with local indication. It is set up by push buttons and auto-senses 22-300VDC or 90-260VAC power.
- Type
- Site-programmable isolated temperature transmitter
- Input
- T/C (all common ISA), 2-, 3- or 4-wire RTD, ohms, mV
- Input modes
- Single sensor, average of multiple sensors, dual sensor differential
- Output
- 4-20mA (source or sink) or 1-5V, switch selectable
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The SPT accepts T/C, RTD, millivolt or ohms input in a host of ranges, sensor types and connection schemes. It provides an isolated, process-ready analogue output along with local indication, in a compact DIN-style housing that fits G-type and Top Hat rails. A switch selects 4-20mA or 1-5V.
The input takes all common ISA thermocouples, 2-, 3- or 4-wire RTDs and direct ohm or millivolt sources. The menu offers output based on a single sensor, the average of multiple sensors, or a dual sensor differential. The 4-20mA output works in source or sink mode.
Setup and calibration need no tools, calibrators or configurators, only push buttons. A large LCD screen leads the user through a simple menu with every option spelled out in plain English. All settings are held in non-volatile memory, protected from power loss and unauthorised changes, and parameters can be viewed at any time without affecting operation. The display shows the input in real time in either °C or °F.
Power is auto-sensing at 22-300VDC or 90-260VAC, with no jumpers or switches to set, so the unit can serve as a universal spare for temperature applications. Output accuracy is ±0.03% of output span, cold junction reference accuracy is ±0.25°C and stability is ±0.1% of calibrated span max over six months. Output limiting is 117% of span max, 115% typical. Load capability is 1200Ω max for current outputs in source mode and 2000Ω max in sink mode.
For hazardous areas the rating is Non-Incendive/Div. 2, Zone 2. Certifications include FM Non-Incendive Class I, Division 2, Groups A, B, C, D, suitability for Class II, Division 2 and Class III, Divisions 1 and 2, and CSA General (Ordinary) Location. The unit is not for use in SIS.
Technical specifications
| Type | Site-programmable isolated temperature transmitter |
|---|---|
| Input | T/C (all common ISA), 2-, 3- or 4-wire RTD, ohms, mV |
| Input modes | Single sensor, average of multiple sensors, dual sensor differential |
| Output | 4-20mA (source or sink) or 1-5V, switch selectable |
| Power | 22-300VDC or 90-260VAC, auto-sensing |
| Power connection | 4-Wire 24DC/117VAC/230VAC line/mains powered |
| Housing | DIN-style, 32mm G-type and 35mm Top Hat |
| Display | LCD, input in °C or °F |
| Configuration | Push button, on-screen menu |
| Isolation | Fully isolated |
| Output accuracy | ±0.03% of output span |
| Cold junction reference accuracy | ±0.25°C |
| Output limiting | 117% of span max, 115% typical |
| Load capability | 1200Ω max (4-20mA, source), 2000Ω max (sink) |
| Stability | ±0.1% of calibrated span max over six months |
| Hazardous area certifications | Non-Incendive/Div. 2, Zone 2 |
| For use in SIS | No |
Part numbers
Show all part numbers (1)
SPT/TPRG/PRG/U [DIN]
How it compares with similar models
| Parameter | SPT site-programmable isolated temperature transmitter, T/C, RTD, ohms, mV, 4-20mA or 1-5V | SPA2 programmable temperature transmitter and alarm trip, RTD, T/C, mV, ohms, 2 relays, analogue output | SPA2IS programmable temperature transmitter and alarm trip with intrinsically safe inputs, 2 relays | THZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DC |
|---|---|---|---|---|
| Type | Site-programmable isolated temperature transmitter | Programmable temperature transmitter and alarm trip | Programmable temperature transmitter and alarm trip with intrinsically safe field connections | Dual input HART temperature transmitter for DIN rail mounting |
| Input | T/C (all common ISA), 2-, 3- or 4-wire RTD, ohms, mV | RTD (23 types), T/C (9 types), mV, ohms, potentiometer | RTD (23 types), T/C (9 types), mV, ohms, potentiometer | Dual sensor, programmable: RTD, T/C, mV, ohms, potentiometer |
| Power | 22-300VDC or 90-260VAC, auto-sensing | 21.6-375VDC or 90-260VAC | 21.6-125VDC or 90-260VAC | 12-42DC, 2-wire, loop powered |
| Housing | DIN-style, 32mm G-type and 35mm Top Hat | DIN-style, 35mm (EN50022) Top Hat DIN rail | DIN-style, 35mm (EN50022) Top Hat DIN rail | DIN rail mount, DIN rail enclosure |
| Display | LCD, input in °C or °F | 5-digit, backlit | 5-digit, backlit | — |
| Configuration | Push button, on-screen menu | PC, USB cable, push buttons | PC, USB cable, push buttons | PC, USB cable, HART |
Request a price and lead time
SPT site-programmable isolated temperature transmitter, T/C, RTD, ohms, mV, 4-20mA or 1-5V. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which inputs does the SPT accept?
All common ISA thermocouples, 2-, 3- or 4-wire RTDs and direct ohm or millivolt sources. Output can follow a single sensor, an average or a differential.
What power does the SPT need?
22-300VDC or 90-260VAC. It is auto-sensing, with no jumpers or switches to set.
What load can the current output drive?
Up to 1200Ω for 4-20mA in source mode and up to 2000Ω in sink mode.