SPA2IS programmable temperature transmitter and alarm trip with intrinsically safe inputs, 2 relays
The SPA2IS takes signals from temperature sensors in intrinsically safe hazardous areas without a separate barrier. Two alarm relays, optional -AO output, 5-digit display, 21.6-125VDC or 90-260VAC power.
- Type
- Programmable temperature transmitter and alarm trip with intrinsically safe field connections
- Input
- RTD (23 types), T/C (9 types), mV, ohms, potentiometer
- Alarm outputs
- Two independent, individually configurable alarm relay outputs
- Analogue output (option -AO)
- Programmable, any range between 0-20mA and 0-10V
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The SPA2IS is a programmable limit alarm trip with intrinsically safe field connections. It accepts signals from temperature sensors located in hazardous areas where the method of protection is Intrinsic Safety. Such installations would normally need an additional intrinsically safe barrier, but the SPA2IS includes field connections that provide the protection typically afforded by a galvanically isolated barrier.
The unit is installed in a safe area or in a Class I, Div 2/Zone 2 area, with sensors in Class I, Div I/Zone 0, 1 locations. The input accepts 23 RTD types, 9 thermocouple types, resistance and potentiometer devices and direct millivolt sources. The 4-wire universal supply is 21.6-125VDC or 90-260VAC.
Two independent, individually configurable alarm relay outputs operate when the monitored variable falls outside the set limits and can drive a light, annunciator, bell, pump, motor or shutdown system. Parameters are set with push buttons or the free Windows software, with password protection. Input resolution is 20-bit and calibration is needed only up to 5 years apart. The large 5-digit backlit display shows the process variable, the output, or toggles between the two.
The -AO option adds a programmable analogue output in any range between 0-20mA and 0-10V. The metal, RFI resistant housing snaps onto 35mm (EN50022) Top Hat DIN rails. The rating is Non-Incendive/Div. 2, Zone 2, Associated Intrinsically-Safe. The unit is not for use in SIS.
Technical specifications
| Type | Programmable temperature transmitter and alarm trip with intrinsically safe field connections |
|---|---|
| Input | RTD (23 types), T/C (9 types), mV, ohms, potentiometer |
| Alarm outputs | Two independent, individually configurable alarm relay outputs |
| Analogue output (option -AO) | Programmable, any range between 0-20mA and 0-10V |
| Power | 21.6-125VDC or 90-260VAC |
| Power connection | 4-Wire 24DC/117VAC/230VAC line/mains powered |
| Housing | DIN-style, 35mm (EN50022) Top Hat DIN rail |
| Display | 5-digit, backlit |
| Input resolution | 20-bit |
| Stability | Up to 5 years between scheduled calibrations |
| Configuration | PC, USB cable, push buttons |
| Isolation | Fully isolated |
| Intrinsically safe input connections | Yes |
| Hazardous area certifications | Non-Incendive/Div. 2, Zone 2, Associated Intrinsically-Safe |
| For use in SIS | No |
| RoHS | Yes |
Part numbers
Show all part numbers (1)
SPA2IS/TPRG/2PRG/U/-AO [DIN]
How it compares with similar models
| Parameter | SPA2IS programmable temperature transmitter and alarm trip with intrinsically safe inputs, 2 relays | SPA2 programmable temperature transmitter and alarm trip, RTD, T/C, mV, ohms, 2 relays, analogue output | THZ3 associated IS dual input HART temperature transmitter (-AIS), 4-20mA, DIN rail | STZ associated IS dual input HART temperature transmitter (-AIS), SIL 2/3, 4-20mA |
|---|---|---|---|---|
| Type | Programmable temperature transmitter and alarm trip with intrinsically safe field connections | Programmable temperature transmitter and alarm trip | Dual input associated IS HART temperature transmitter | Functional safety dual input associated IS HART temperature transmitter |
| Input | RTD (23 types), T/C (9 types), mV, ohms, potentiometer | RTD (23 types), T/C (9 types), mV, ohms, potentiometer | Dual sensor, programmable: RTD, T/C, mV, ohms, potentiometer | One or two sensors: RTD, T/C, mV, ohms, potentiometer |
| Power | 21.6-125VDC or 90-260VAC | 21.6-375VDC or 90-260VAC | 12-42DC, 2-wire, loop powered | 12-42DC, 2-wire, loop powered |
| Housing | DIN-style, 35mm (EN50022) Top Hat DIN rail | DIN-style, 35mm (EN50022) Top Hat DIN rail | DIN rail mount, DIN rail enclosure | DIN rail mount, DIN rail enclosure |
| Configuration | PC, USB cable, push buttons | PC, USB cable, push buttons | PC, USB cable, HART | PC, USB cable, HART |
| Intrinsically safe input connections | Yes | No | Yes | Yes |
Request a price and lead time
SPA2IS programmable temperature transmitter and alarm trip with intrinsically safe inputs, 2 relays. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Does the SPA2IS need an intrinsically safe barrier?
No, its built-in intrinsically safe field connections provide the protection of a galvanically isolated barrier.
Where is the SPA2IS installed and where can the sensors be?
The unit goes in a safe area or Class I, Div 2/Zone 2, and the sensors in Class I, Div I/Zone 0, 1 locations.
What power does the SPA2IS need?
Universal 4-wire: 21.6-125VDC or 90-260VAC.