SPA2IS programmable temperature transmitter and alarm trip with intrinsically safe inputs, 2 relays

The SPA2IS takes signals from temperature sensors in intrinsically safe hazardous areas without a separate barrier. Two alarm relays, optional -AO output, 5-digit display, 21.6-125VDC or 90-260VAC power.

Type
Programmable temperature transmitter and alarm trip with intrinsically safe field connections
Input
RTD (23 types), T/C (9 types), mV, ohms, potentiometer
Alarm outputs
Two independent, individually configurable alarm relay outputs
Analogue output (option -AO)
Programmable, any range between 0-20mA and 0-10V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The SPA2IS is a programmable limit alarm trip with intrinsically safe field connections. It accepts signals from temperature sensors located in hazardous areas where the method of protection is Intrinsic Safety. Such installations would normally need an additional intrinsically safe barrier, but the SPA2IS includes field connections that provide the protection typically afforded by a galvanically isolated barrier.

The unit is installed in a safe area or in a Class I, Div 2/Zone 2 area, with sensors in Class I, Div I/Zone 0, 1 locations. The input accepts 23 RTD types, 9 thermocouple types, resistance and potentiometer devices and direct millivolt sources. The 4-wire universal supply is 21.6-125VDC or 90-260VAC.

Two independent, individually configurable alarm relay outputs operate when the monitored variable falls outside the set limits and can drive a light, annunciator, bell, pump, motor or shutdown system. Parameters are set with push buttons or the free Windows software, with password protection. Input resolution is 20-bit and calibration is needed only up to 5 years apart. The large 5-digit backlit display shows the process variable, the output, or toggles between the two.

The -AO option adds a programmable analogue output in any range between 0-20mA and 0-10V. The metal, RFI resistant housing snaps onto 35mm (EN50022) Top Hat DIN rails. The rating is Non-Incendive/Div. 2, Zone 2, Associated Intrinsically-Safe. The unit is not for use in SIS.

Technical specifications

TypeProgrammable temperature transmitter and alarm trip with intrinsically safe field connections
InputRTD (23 types), T/C (9 types), mV, ohms, potentiometer
Alarm outputsTwo independent, individually configurable alarm relay outputs
Analogue output (option -AO)Programmable, any range between 0-20mA and 0-10V
Power21.6-125VDC or 90-260VAC
Power connection4-Wire 24DC/117VAC/230VAC line/mains powered
HousingDIN-style, 35mm (EN50022) Top Hat DIN rail
Display5-digit, backlit
Input resolution20-bit
StabilityUp to 5 years between scheduled calibrations
ConfigurationPC, USB cable, push buttons
IsolationFully isolated
Intrinsically safe input connectionsYes
Hazardous area certificationsNon-Incendive/Div. 2, Zone 2, Associated Intrinsically-Safe
For use in SISNo
RoHSYes

Part numbers

Show all part numbers (1)

SPA2IS/TPRG/2PRG/U/-AO [DIN]

How it compares with similar models

ParameterSPA2IS programmable temperature transmitter and alarm trip with intrinsically safe inputs, 2 relaysSPA2 programmable temperature transmitter and alarm trip, RTD, T/C, mV, ohms, 2 relays, analogue outputTHZ3 associated IS dual input HART temperature transmitter (-AIS), 4-20mA, DIN railSTZ associated IS dual input HART temperature transmitter (-AIS), SIL 2/3, 4-20mA
TypeProgrammable temperature transmitter and alarm trip with intrinsically safe field connectionsProgrammable temperature transmitter and alarm tripDual input associated IS HART temperature transmitterFunctional safety dual input associated IS HART temperature transmitter
InputRTD (23 types), T/C (9 types), mV, ohms, potentiometerRTD (23 types), T/C (9 types), mV, ohms, potentiometerDual sensor, programmable: RTD, T/C, mV, ohms, potentiometerOne or two sensors: RTD, T/C, mV, ohms, potentiometer
Power21.6-125VDC or 90-260VAC21.6-375VDC or 90-260VAC12-42DC, 2-wire, loop powered12-42DC, 2-wire, loop powered
HousingDIN-style, 35mm (EN50022) Top Hat DIN railDIN-style, 35mm (EN50022) Top Hat DIN railDIN rail mount, DIN rail enclosureDIN rail mount, DIN rail enclosure
ConfigurationPC, USB cable, push buttonsPC, USB cable, push buttonsPC, USB cable, HARTPC, USB cable, HART
Intrinsically safe input connectionsYesNoYesYes

Request a price and lead time

SPA2IS programmable temperature transmitter and alarm trip with intrinsically safe inputs, 2 relays. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the SPA2IS need an intrinsically safe barrier?

No, its built-in intrinsically safe field connections provide the protection of a galvanically isolated barrier.

Where is the SPA2IS installed and where can the sensors be?

The unit goes in a safe area or Class I, Div 2/Zone 2, and the sensors in Class I, Div I/Zone 0, 1 locations.

What power does the SPA2IS need?

Universal 4-wire: 21.6-125VDC or 90-260VAC.