SST SIL 2 Capable Signal Isolator, IEC 61508, HART Pass-Through, Active or Passive Input and Output

The SST is a four-wire signal isolator from the functional safety series, certified to SIL 2 under IEC 61508. It passes HART signals with full three-way isolation, and on input failure its output falls to 0 mA.

Purpose
signal isolation in safety instrumented system loops
Functional safety
SIL 2 to IEC 61508
Signal
analogue current with HART pass-through
Input
active (powers a two-wire transmitter) or passive

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The SST is used in safety instrumented loops at chemical and oil and gas sites, in mining and metal refining, and in power generation and transmission plants. At the design stage of a safety system the conditions of each loop are not always known. Input cards may be active or passive, field transmitters may be mains-powered on a four-wire arrangement with an active output or run as two-wire passive devices, and some support HART while others do not. The SST covers all of these variants with one type of instrument.

On site, the input is wired as active when the SST powers a two-wire transmitter, or as passive. The output can be ordered as active or passive. The unit provides full three-way galvanic isolation between input, output and power, rejects noise on the line and passes HART digital signals, so the set-up and diagnostics of the field instrument stay accessible from the control system.

Failure behaviour matters in a safety loop. The SST output tracks the input down to 0 mA, so a broken wire or an input failure is clearly recognised by the logic solver.

The isolator is certified by an independent body to SIL 2 under IEC 61508. Power can be chosen from +24 V, 110 VAC or 220 VAC to match the cabinet design, and the unit is installed in safety instrumented system cabinets alongside other functional safety devices.

Technical specifications

Purposesignal isolation in safety instrumented system loops
Functional safetySIL 2 to IEC 61508
Signalanalogue current with HART pass-through
Inputactive (powers a two-wire transmitter) or passive
Outputactive or passive, to order
Isolationfull three-way
Behaviour on input failureoutput falls to 0 mA
Wiringfour-wire
Power supply+24 V, 110 VAC, 220 VAC
Industrieschemicals, upstream oil and gas, mining and metal refining, power generation and transmission

Part numbers

Show all part numbers (1)

SST

Request a price and lead time

SST SIL 2 Capable Signal Isolator, IEC 61508, HART Pass-Through, Active or Passive Input and Output. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What does the output do when the input fails?

It falls to 0 mA, so a broken wire or input failure is clearly recognised by the logic solver. The unit is certified to SIL 2 under IEC 61508.

Can a two-wire transmitter be connected without a separate power supply?

Yes. The SST input can be wired as active, in which case it powers the two-wire field transmitter.

Can the SST pass HART signals?

Yes. HART passes through the isolator, so the set-up and diagnostics of the field instrument remain available from the control system.