SFY functional safety frequency-to-current transmitter with display, SIL 3, 4-20 mA

The SFY measures frequency, period, pulse width or contact closure and converts it to an isolated, linear 4-20 mA output. It is loop powered at 12-42 Vdc, has a 5-digit display and is set up from a PC. exida certifies it to IEC 61508.

Input
frequency, period, pulse width, contact closure (programmable)
Frequency range
0.005 Hz-25 kHz
Period range
40 microseconds-200 seconds
Pulse width
0.2 ms-200 seconds

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

A member of the FS Functional Safety Series, the SFY is a loop-powered frequency-to-DC transmitter for safety instrumented systems (SIS). It monitors frequency, period, high or low pulse width and contact closure, and converts the input to a proportional 4-20 mA output isolated from the input, ready for a safety system, readout instrument, recorder, PLC, DCS or SCADA.

Input ranges are frequency from 0.005 Hz to 25 kHz, periods from 40 microseconds to 200 seconds and pulse widths from 0.2 ms to 200 seconds. The SFY/PRG version accepts 20 mV-30 Vac or 100 mV-30 Vdc, and the SFY/10-250AC version accepts 10-250 Vac or 100 mV-30 Vdc. A programmable moving average filter limits measurement instability caused by effects such as bent turbine blades. A 5-digit LCD shows the process variable in selectable engineering units.

Typical accuracy is ±0.025% of span, with up to 5 years between scheduled calibrations. The unit is loop powered from 12-42 Vdc. Input and output are isolated and the unit is RFI/EMI protected, so ground loops and plant noise have little effect. All parameters are chosen and checked in the PC configuration software, and set-up takes minutes.

exida certifies the SFY to IEC 61508:2010 for systematic integrity up to SIL 3 and random integrity up to SIL 2. It is therefore approved for single use in an SIS up to SIL 2 and in redundant architecture (1oo2, 2oo3 and so on) up to SIL 3. FMEDA data are available on request. Uses include turbine over-speed protection, critical exhaust fans for personnel safety and compressor monitoring, with signals from turbine tachometer generators, turbine flow meters, magnetic pickups, dry contacts, variable frequency drives, rotating equipment, and motor and conveyor speed sensors.

It mounts on a surface, DIN rail or relay track, or in protective field-mount enclosures. The SFY-HP has Factory Mutual Non-Incendive approval, Class I, Division 2, Groups A, B, C and D (PRG input only), and conforms to EMC Directive 2014/30/EU (EN 61326).

Technical specifications

Inputfrequency, period, pulse width, contact closure (programmable)
Frequency range0.005 Hz-25 kHz
Period range40 microseconds-200 seconds
Pulse width0.2 ms-200 seconds
SFY/PRG input20 mV-30 Vac or 100 mV-30 Vdc
SFY/10-250AC input10-250 Vac or 100 mV-30 Vdc
Output4-20 mA, isolated, scalable
Power supply12-42 Vdc, 2-wire, loop powered
Accuracy±0.025% of span, typical
Calibration intervalup to 5 years
Display5-digit LCD, selectable units
Functional safetyIEC 61508:2010, SIL 2 single use, SIL 3 redundant
Hazardous areasNon-Incendive/Div. 2, Zone 2

Part numbers

Show all part numbers (2)

SFY/PRG/4-20mA/12-42DC [DN], SFY/10-250AC

How it compares with similar models

ParameterSFY functional safety frequency-to-current transmitter with display, SIL 3, 4-20 mASLD functional safety programmable loop display, 4-20 mA, loop poweredFDY PC-Programmable 2-Wire Frequency-to-DC Transmitter with Display, 4-20 mA OutputSTZ dual input HART temperature transmitter for safety systems, SIL 2/3, associated IS
Inputfrequency, period, pulse width, contact closure (programmable)4-20 mA—single or dual, programmable: RTD, thermocouple, ohms, mV, potentiometer
Output4-20 mA, isolated, scalable—4-20 mA, isolated, scaleable4-20 mA, one analogue output
Power supply12-42 Vdc, 2-wire, loop poweredfrom the loop, voltage drop under 2.3 V—12-42 Vdc, 2-wire, from the output loop
Calibration intervalup to 5 yearsup to 5 yearsUp to 5 years—
Display5-digit LCD, selectable unitstwo rows of large characters; mA, percent or units up to 5 characters5-digit LCD, selectable engineering unitsnone
Functional safetyIEC 61508:2010, SIL 2 single use, SIL 3 redundantSIL 3, non-interfering in a safety loop—SIL 2/3, IEC 61508 certificate

Request a price and lead time

SFY functional safety frequency-to-current transmitter with display, SIL 3, 4-20 mA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What signals can the SFY measure?

Frequency from 0.005 Hz to 25 kHz, period from 40 microseconds to 200 seconds, pulse width from 0.2 ms to 200 seconds, and contact closure.

Up to which SIL is the SFY approved?

Up to SIL 2 in single use and up to SIL 3 in redundant architecture, under IEC 61508:2010.

How do the SFY/PRG and SFY/10-250AC differ?

The SFY/PRG takes 20 mV-30 Vac or 100 mV-30 Vdc, and the SFY/10-250AC takes 10-250 Vac or 100 mV-30 Vdc.