International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

FDY PC-Programmable 2-Wire Frequency-to-DC Transmitter with Display, 4-20 mA Output

The FDY reads frequency, period, pulse width and contact closure and converts it to an isolated, proportional 4-20 mA signal. Frequency range is 0.005 Hz to 25 kHz, a 5-digit LCD shows the value, setup is by PC over USB, and the loop supplies 12-42 V DC.

Type
PC-programmable frequency-to-DC transmitter, 2-wire
Input (PRG)
Frequency, period, high or low pulse width, contact closure
Frequency range
0.005 Hz to 25 kHz
Period range
40 microseconds to 200 s

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The FDY monitors frequency, period, high or low pulse width and contact closure signals. It converts the input to a proportional, input-to-output isolated 4-20 mA signal for direct connection to a readout instrument, recorder, PLC, DCS or SCADA system. It is a 2-wire transmitter powered from the output loop at 12-42 V DC.

Measuring ranges are 0.005 Hz to 25 kHz for frequency, 40 microseconds to 200 s for period and 0.2 ms to 200 s for pulse width. Typical accuracy is +/-0.025 % of span, with up to 5 years between scheduled calibrations. A 5-digit LCD shows the process variable in selectable engineering units.

Application-specific parameters are entered in a few minutes with the PC configuration software, using a USB cable. All operating parameters are chosen, and then viewed to confirm, in a single window. A programmable moving average filter is set to the number of turbine blades; it smooths the reading and removes the instability that bent blades cause.

Typical uses are turbine tachometer generators and flow meters, magnetic pickups, dry contact closures, variable frequency drives, rotating equipment, pulse and frequency output transducers, and motor and conveyor speed. For generator frequency monitoring the 4-20 mA span can be set narrowly around the set point, for example 55-65 Hz on a 60 Hz system.

Input-to-output isolation and RFI/EMI protection guard against ground loops and plant noise. The housing is a hockey puck style case with a DIN-rail clip, 76 x 66 x 61 mm. Operating temperature is -40 to +85 degrees C and humidity 0-95 % non-condensing. Protective enclosures are available for field mounting. Approvals: UL, Non-Incendive/Div. 2, Zone 2 and RoHS; standards SAMA 33.1 abc and IEC1000-4-3-1995.

Technical specifications

TypePC-programmable frequency-to-DC transmitter, 2-wire
Input (PRG)Frequency, period, high or low pulse width, contact closure
Frequency range0.005 Hz to 25 kHz
Period range40 microseconds to 200 s
Pulse width0.2 ms to 200 s
Output4-20 mA, isolated, scaleable
Power12-42 V DC, output loop powered
Typical accuracy+/-0.025 % of span
Calibration intervalUp to 5 years
Display5-digit LCD, selectable engineering units
ConfigurationPC software, USB cable
HousingHockey puck style with DIN-rail clip
Dimensions76 x 66 x 61 mm
Operating temperature-40 to +85 degrees C
Humidity0-95 %, non-condensing
ApprovalsUL, Non-Incendive/Div. 2, Zone 2, RoHS

Part numbers

Show all part numbers (1)

FDY/PRG/4-20mA/12-42DC [DN]

How it compares with similar models

ParameterFDY PC-Programmable 2-Wire Frequency-to-DC Transmitter with Display, 4-20 mA OutputSFY functional safety frequency-to-current transmitter with display, SIL 3, 4-20 mASIX 1-5V/4-20mA 2-Wire Signal Isolator and Converter, 1500 Vrms IsolationSDY PC-programmable signal isolator and converter with display, 4-20 mA output
Output4-20 mA, isolated, scaleable4-20 mA, isolated, scalable4-20 mA4-20 mA, isolated, scalable
Display5-digit LCD, selectable engineering units5-digit LCD, selectable units—two rows of large characters, any units

Request a price and lead time

FDY PC-Programmable 2-Wire Frequency-to-DC Transmitter with Display, 4-20 mA Output. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which input signals can the FDY measure?

Frequency, period, high or low pulse width and contact closure. The frequency range is 0.005 Hz to 25 kHz.

How is the FDY configured?

From a PC with the configuration software over a USB cable. All operating parameters are selected and confirmed in one window.

How can the FDY steady a turbine flow reading?

Its programmable moving average filter is set to the number of turbine blades and averages out the variation that bent blades cause.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides