EP-FDX Extended Performance 2-Wire Frequency-to-DC Transmitter, 4-20 mA or 10-50 mA Output
The EP-FDX turns the varying frequency from a flowmeter into a proportional 4-20 mA or 10-50 mA current. Input ranges from 3.12 Hz to 6400 Hz are chosen by jumpers, input sensitivity is 10 mV to 300 mV, and calibration capability is +/-0.05 % of span.
- Type
- Frequency-to-DC transmitter, 2-wire
- Input range
- 3.12 Hz to 6400 Hz, selected with solderless jumpers
- Input sensitivity
- 10 mV to 300 mV, independent of frequency
- Contact closure input
- With de-bounce circuitry
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The EP-FDX, with field-selectable ranges, is a two-wire transmitter that converts varying frequency signals into DC current signals better suited to field transmission. It usually takes its input from a flow measurement device such as a turbine, vortex shedding or positive displacement meter and yields a proportional 4-20 mA or 10-50 mA output. It can be linked to many analog and digital instruments, for controller interface, computer interface, data transmission and other process functions.
Input ranges from 3.12 Hz to 6400 Hz are selected in the field with solderless jumpers, which suits frequency-generating devices such as turbine and positive displacement meters, magnetic shaft speed pickups and contact closures. Calibration capability is +/-0.05 % of span. Stability is +/-0.01 % of span per degree F, +/-0.002 % of span per 100 ohm change in loop resistance and +/-0.002 % of span per volt change in line voltage.
Input sensitivity is adjustable from 10 mV to 300 mV, so low-level signals can be measured and noisy ones filtered out. Unlike some other frequency-to-current converters, the response is essentially flat and the sensitivity does not depend on input frequency. A field-selectable contact closure input has de-bounce circuitry, so dry contacts do not register false counts. The -RF option adds a filter against radio frequency interference.
Housings: HP hockey-puck with flanges for relay-track or surface mounting, or with spring clips for explosion-proof enclosures; a DIN-style rail housing 1 inch wide for high-density installation; OT oil-tight (NEMA 12); WT water-tight (NEMA 4); and HG explosion-proof with a high glass dome that has room for a display indicator beside the transmitter.
Approvals: CSA General (Ordinary) Location; CE to EMC Directive 89/336/EEC, EN 50081-2 and EN 50082-2.
Technical specifications
| Type | Frequency-to-DC transmitter, 2-wire |
|---|---|
| Input range | 3.12 Hz to 6400 Hz, selected with solderless jumpers |
| Input sensitivity | 10 mV to 300 mV, independent of frequency |
| Contact closure input | With de-bounce circuitry |
| Output | 4-20 mA or 10-50 mA |
| Calibration capability | +/-0.05 % of span |
| Stability | +/-0.01 % of span per degree F; +/-0.002 % of span per 100 ohm loop resistance; +/-0.002 % of span per volt line voltage |
| Option -RF | Filter against radio frequency interference |
| Housings | HP, DIN 1 inch wide, OT (NEMA 12), WT (NEMA 4), HG explosion-proof |
| Approvals | CSA General (Ordinary) Location; CE, EMC 89/336/EEC, EN 50081-2, EN 50082-2 |
Part numbers
Show all part numbers (1)
EP-FDX
How it compares with similar models
| Parameter | EP-FDX Extended Performance 2-Wire Frequency-to-DC Transmitter, 4-20 mA or 10-50 mA Output | FDT 4-Wire Frequency-to-DC Transmitter with Quartz Crystal Time Base | PTT 4-Wire Potentiometer Transmitter, 100 to 10,000 ohm Input, Current or Voltage Output | ACX 2-Wire AC Current Isolator and Transmitter, 4-20 mA Output, 12-42 V DC Loop Power |
|---|---|---|---|---|
| Type | Frequency-to-DC transmitter, 2-wire | Frequency-to-DC transmitter, 4-wire | Potentiometer transmitter, 4-wire | AC current and voltage isolator and transmitter, 2-wire |
| Output | 4-20 mA or 10-50 mA | Proportional current or voltage | 4-20 mA, 1-5 Vdc or other current or voltage ranges | 4-20 mA into 600 ohms at 24 Vdc; 10-50 mA into 600 ohms at 42 Vdc |
| Option -RF | Filter against radio frequency interference | Protection against radio frequency and electromagnetic interference | Filter against radio frequency interference | — |
| Housings | HP, DIN 1 inch wide, OT (NEMA 12), WT (NEMA 4), HG explosion-proof | Standard surface-mount; plug-in card | Standard; PC; PM (3-1/2 by 7-1/8 inch panel space); EX; OT; WT | DIN aluminium (G-type rail), HP, FL, 2LS |
| Approvals | CSA General (Ordinary) Location; CE, EMC 89/336/EEC, EN 50081-2, EN 50082-2 | CSA General Locations; Division I, Class I, Groups C and D; City of Los Angeles General Locations | — | CE (EMC 2014/30/EU, EN61326); FM, CSA, ATEX, ANZEx for explosion-proof enclosure versions |
Request a price and lead time
EP-FDX Extended Performance 2-Wire Frequency-to-DC Transmitter, 4-20 mA or 10-50 mA Output. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What input frequency range does the EP-FDX cover?
3.12 Hz to 6400 Hz, selected in the field with solderless jumpers.
Which sensors can feed the EP-FDX?
Turbine, vortex shedding and positive displacement flowmeters, magnetic shaft speed pickups and dry contact closures.
What is the output signal?
A DC current of 4-20 mA or 10-50 mA proportional to the input frequency.