ACT 4-Wire AC Current and Voltage Transmitter with Input-Output Isolation

The ACT takes an AC current or voltage from a motor or current transformer and returns a proportional standard current or voltage signal. Input and output are fully isolated, calibration capability is +/-0.5 % of span, and ZERO and SPAN are set from the front panel.

Type
AC current and voltage transmitter, 4-wire
Current input
0-1, 0-2, 0-3, 0-4 or 0-5 A AC, 0.1 ohm impedance
Voltage input
Up to 0-150 VAC, 1000 ohms per volt
Current output
1-5 mA into 0-4800 ohms; 4-20 mA into 0-1200 ohms

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ACT accepts an AC voltage or current from a motor, a current transformer or a similar source and turns it into a standard process current or voltage signal. It is a 4-wire unit, factory-configured for the chosen input and output type and rating. Current outputs are 1-5 mA into 0-4800 ohms and 4-20 mA into 0-1200 ohms.

Current inputs run 0-1, 0-2, 0-3, 0-4 or 0-5 A AC into 0.1 ohm. Voltage inputs cover ranges up to 0-150 VAC, including 0-5, 0-10, 0-25 and 0-120 VAC, at 1000 ohms per volt. Current transformers handle inputs above the standard ranges.

An internal toroidal input transformer steps 0-5 A down to 0-5 mA, isolates the input and tolerates large momentary surges. With the -EM option the transformer is mounted outside the unit, so servicing needs no opening of the customer's current transformer secondary. Overload capability is 35 A for 30 seconds with -EM, and 150 % overvoltage on voltage inputs.

Input and output are transformer isolated to 500 Vrms with no DC connection between them, and common mode rejection exceeds 120 dB at 60 Hz. Calibration capability is +/-0.5 % of span, ripple is below 10 mV peak-to-peak, load effect is +/-0.01 % of span and ambient range is -29 to +82 degrees C. External multiturn potentiometers adjust ZERO (+/-10 %) and SPAN (+/-20 %) on the front panel; there are no indicators. Weight is 900 g.

Housings: STD with aluminium case and mounting bracket, powered from AC or DC; PC plug-in card for a card rack, DC only, with -EM required on current inputs; and EX for an explosion-proof enclosure, with connections moved to the bottom and a mating connector block supplied. Approvals: CSA General Location for STD, CSA explosion-proof Groups C and D for EX, and City of Los Angeles General Location. The -RF option adds RFI/EMI protection.

Technical specifications

TypeAC current and voltage transmitter, 4-wire
Current input0-1, 0-2, 0-3, 0-4 or 0-5 A AC, 0.1 ohm impedance
Voltage inputUp to 0-150 VAC, 1000 ohms per volt
Current output1-5 mA into 0-4800 ohms; 4-20 mA into 0-1200 ohms
IsolationTransformer isolated, to 500 Vrms
Common mode rejectionExceeds 120 dB at 60 Hz
Calibration capability+/-0.5 % of span
Overload35 A for 30 seconds with -EM option; 150 % overvoltage
RippleBelow 10 mV peak-to-peak
Ambient range-29 to +82 degrees C
AdjustmentsZERO +/-10 %, SPAN +/-20 %, front-panel potentiometers
HousingsSTD, PC (card rack, DC only), EX (explosion-proof enclosure)
Weight900 g
ApprovalsCSA General Location; CSA Groups C and D (EX); City of Los Angeles General Location

Part numbers

Show all part numbers (1)

ACT

How it compares with similar models

ParameterACT 4-Wire AC Current and Voltage Transmitter with Input-Output IsolationACX 2-Wire AC Current Isolator and Transmitter, 4-20 mA Output, 12-42 V DC Loop PowerASM 4-Wire Adder Subtractor Module for Two to Four Analog InputsADB 4-Wire Analog Divider Module, Current or Voltage Output Proportional to the Quotient of Two Inputs
TypeAC current and voltage transmitter, 4-wireAC current and voltage isolator and transmitter, 2-wireAdder-subtractor module, 4-wireAnalog divider module, 4-wire
Current input0-1, 0-2, 0-3, 0-4 or 0-5 A AC, 0.1 ohm impedance0-1, 0-2, 0-3, 0-4 or 0-5 A AC, 0.1 ohm impedance1-5 mA into 1000 ohms; 4-20 mA into 250 ohms; 10-50 mA into 100 ohms1-5 mA into 200 ohms; 4-20 mA into 50 ohms; 10-50 mA into 20 ohms
Voltage inputUp to 0-150 VAC, 1000 ohms per volt0-0.5, 0-1.5, 0-5, 0-10, 0-25, 0-50, 0-120 or 0-150 VAC, 100 ohms per volt0-5 V, 1-5 V, 250,000 ohms minimum0-5 V, 1-5 V standard, 0.5 megohm; others optional
Current output1-5 mA into 0-4800 ohms; 4-20 mA into 0-1200 ohms—1-5 mA into 0-4800 ohms; 4-20 mA into 0-1200 ohms; 10-50 mA into 0-480 ohms1-5 mA into 0-4800 ohms; 4-20 mA into 0-1200 ohms; 10-50 mA into 0-480 ohms
Calibration capability+/-0.5 % of span+/-0.2 % of span; +/-0.5 % at 0-10 Vac and lower+/-0.5 % of span+/-0.25 % of span
RippleBelow 10 mV peak-to-peak10 mV peak-to-peak maximum10 mV peak-to-peakBelow 0.25 % of maximum signal, 10 mV peak-to-peak on 5 V

Request a price and lead time

ACT 4-Wire AC Current and Voltage Transmitter with Input-Output Isolation. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What input signals does the ACT accept?

AC current of 0-1, 0-2, 0-3, 0-4 or 0-5 A and AC voltage up to 0-150 V. The input type is set at the factory.

What is the -EM option for?

It places the input transformer outside the unit so servicing does not require opening the current transformer secondary. It is mandatory on PC housings with a current input.

How are the STD and PC housings powered?

The STD unit runs from AC or DC power; the PC unit runs from DC only.

Similar equipment from other manufacturers