SPD Programmable Field-Mount Loop Display, 4-20 mA, NEMA 4X / IP66
The SPD is a universal programmable 4-20 mA loop display in an aluminium NEMA 4X/IP66 field enclosure. Its 5-digit display shows mA, percent or engineering units. It is loop powered with a 2.3 V drop and has ±0.012% accuracy of input scale.
- Model
- SPD/4-20MA/PRG/2.3VLP [FH]
- Type
- Programmable field-mount loop display
- Input
- 4-20 mA
- Power
- Loop powered, 2.3 V
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
SPD/4-20MA/PRG/2.3VLP [FH] accepts a 4-20 mA input from a process transmitter or a similar analogue device and shows real-time process status in mA, percent or any designated engineering unit (EGU) on its 5-digit display. Both the process value and an engineering unit of up to 5 characters appear on the screen.
The LCD has a top row with digits 29.21 mm (1.15 in) high and a bottom row of 15.24 mm (0.6 in). The range is -99999 to 99999 with a 100 ms update. Accuracy is ±0.012% of input scale and resolution 0.0028%. The unit is loop powered (2-wire), with a 2.3 V drop and an equivalent resistance of 115 ohms at 20 mA, so it burdens most loops little. Minimum input signal is 3.8 mA, over-current protection 100 mA, input overrange 24 mA, and response time in normal linearisation mode is 180 ms or less.
Set-up is made on a PC with the Intelligent PC Configuration Software, which takes about a minute, or on site with the front-panel keys guided by prompts on the display. A square root or linear curve can be picked from the library, or a custom curve of up to 128 points created. The filter is programmable for 50 or 60 Hz. Options include -BL (back-light, needs +24 Vdc), -LMD and -2PRG (two alarm relays); this version has no relays.
The enclosure is aluminium, NEMA 4X/IP66, for surface or 2-inch pipe mounting, with a standard (NPT) conduit connection. The ambient operating range is -40 to +85 °C. The certification is CSA Non-Incendive Class I, Div. 2, Groups A, B, C, D, and Class II and III, Division 2, Groups F and G, temperature code T5@85°C/T6@60°C. The unit conforms to EN 61326.
Technical specifications
| Model | SPD/4-20MA/PRG/2.3VLP [FH] |
|---|---|
| Type | Programmable field-mount loop display |
| Input | 4-20 mA |
| Power | Loop powered, 2.3 V |
| Accuracy | ±0.012% of input scale |
| Display | LCD, top row 29.21 mm (1.15 in), bottom row 15.24 mm (0.6 in) |
| Display range | -99999 to 99999 |
| Display update | 100 ms |
| Voltage drop | 2.3 V (115 ohms at 20 mA) |
| Linearisation | Square root, linear, custom curve up to 128 points |
| Operating temperature | -40 to +85 °C |
| Enclosure | Aluminium, NEMA 4X/IP66, surface or 2-inch pipe mount |
| Conduit connection | Standard (NPT) |
| Alarm/relay | None |
| Certification | CSA Non-Incendive Class I, Div. 2, Groups A, B, C, D; T5@85°C/T6@60°C |
Part numbers
Show all part numbers (1)
SPD/4-20MA/PRG/2.3VLP [FH]
How it compares with similar models
| Parameter | SPD Programmable Field-Mount Loop Display, 4-20 mA, NEMA 4X / IP66 | PSD PC-Programmable Loop Display, 4-20 mA, loop powered | DSX Digital Indicator, 2-wire loop powered, 4-20 mA, 3-1/2 digit LCD | SLD functional safety programmable loop display, 4-20 mA, loop powered |
|---|---|---|---|---|
| Type | Programmable field-mount loop display | 2-wire loop display, PC-programmable | 2-wire loop-powered digital indicator | — |
| Accuracy | ±0.012% of input scale | ±0.012% of input scale | ±0.1% of span ±1 count (0-100%) | ±0.012% of input scale |
| Display | LCD, top row 29.21 mm (1.15 in), bottom row 15.24 mm (0.6 in) | LCD, top row 10 mm (0.4 in), bottom row 6 mm (0.23 in) | LCD, 3-1/2 active digits, 8.9 mm (0.35 in) numerals | two rows of large characters; mA, percent or units up to 5 characters |
| Display range | -99999 to 99999 | -99999 to 99999 | -19990 to +19990, minimum span 2000 counts | — |
| Display update | 100 ms | 100 ms | 2.5 times per second | — |
Request a price and lead time
SPD Programmable Field-Mount Loop Display, 4-20 mA, NEMA 4X / IP66. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How is the SPD configured?
On a PC with the Intelligent PC Configuration Software, or on site with the front-panel keys and display prompts.
What are the temperature range and enclosure rating?
-40 to +85 °C, in a NEMA 4X/IP66 enclosure.
Does it need a separate supply?
No, it is powered from the 4-20 mA loop with a 2.3 V drop. The -BL back-light needs +24 Vdc.
Similar equipment from other manufacturers