SSX 2-wire HART safety isolator, SIL 3, 4-20 mA

The SSX is a 2-wire isolator powered from the output side of the loop, for safety instrumented systems. It isolates a 4-20 mA signal at 1500 Vrms and passes HART data in both directions. It is exida certified to IEC 61508 for use up to SIL 3 in monitor mode.

Input
4-20 mA
Output
4-20 mA, one analogue output
Power supply
12-42 Vdc, 2-wire, from the output loop
Input resistance with -IZ250
250 ohms

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Part of the FS Functional Safety Series, the SSX draws its power from the output side of the loop, typically from a DCS or PLC, and gives galvanic isolation between input and output. It separates a safety instrumented system (SIS) from the basic process control or monitoring system, so a disconnection or failure there does not reach the safety system. With 1500 Vrms isolation it also protects safety I/O cards from surges, spikes and transients in the field.

The standard SSX/4-20mA/4-20mA/12-42DC has a 4-20 mA input, a 4-20 mA output and a 12-42 Vdc supply. Its loop function is signal isolator, repeater or splitter, with one analogue output. Loop burden is 8.2 V.

HART data pass through the unit in both directions, so diagnostic, process and calibration information can be read on either side, whereas most isolators strip the HART signal. The -0HART option removes the pass-through, -IZ250 sets 250 ohms input resistance, and the -LMD loop maintenance diode lets the unit be taken out of the loop without interrupting the safety function.

The SSX is certified by exida to IEC 61508:2010. It is approved for an SIS up to SIL 3 in monitor mode, where only the input circuit is part of the safety function, and up to SIL 2 in single use. FMEDA data are available on request. Standard RFI/EMI protection is 20 V/m, and the hazardous-area certification is Non-Incendive/Div. 2, Zone 2.

The metal DIN housing snaps onto 35 mm Top Hat or 32 mm G-type rail (EN 50022, EN 50035). The unit is RoHS compliant.

Technical specifications

Input4-20 mA
Output4-20 mA, one analogue output
Power supply12-42 Vdc, 2-wire, from the output loop
Input resistance with -IZ250250 ohms
Loop burden8.2 V
Isolation1500 Vrms
HARTdata pass-through (-0HART removes it)
Option-LMD, loop maintenance diode
Functional safetyIEC 61508:2010, SIL 3 in monitor mode, SIL 2 in single use
RFI/EMI protection20 V/m
Hazardous areasNon-Incendive/Div. 2, Zone 2
Housingmetal, 35 mm Top Hat or 32 mm G-type DIN rail

Part numbers

Show all part numbers (1)

SSX/4-20mA/4-20mA/12-42DC [DIN]

How it compares with similar models

ParameterSSX 2-wire HART safety isolator, SIL 3, 4-20 mASTZ dual input HART temperature transmitter for safety systems, SIL 2/3, associated ISSLD functional safety programmable loop display, 4-20 mA, loop poweredSST functional safety signal isolator and splitter, 4-20mA, HART pass-through
Input4-20 mAsingle or dual, programmable: RTD, thermocouple, ohms, mV, potentiometer4-20 mA4-20mA
Output4-20 mA, one analogue output4-20 mA, one analogue output—4-20mA (1 analogue output)
Power supply12-42 Vdc, 2-wire, from the output loop12-42 Vdc, 2-wire, from the output loopfrom the loop, voltage drop under 2.3 V—
Option-LMD, loop maintenance diode-AIS, associated IS input connections-LMD, loop maintenance diode—
Functional safetyIEC 61508:2010, SIL 3 in monitor mode, SIL 2 in single useSIL 2/3, IEC 61508 certificateSIL 3, non-interfering in a safety loopSIL 3 capable, IEC 61508 certificate
Hazardous areasNon-Incendive/Div. 2, Zone 2Associated Intrinsically-Safe, Non-Incendive/Div. 2, Zone 2Non-Incendive/Div. 2, Zone 2—

Request a price and lead time

SSX 2-wire HART safety isolator, SIL 3, 4-20 mA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the HART signal pass through the SSX?

Yes. HART diagnostic, process and calibration data pass in both directions, and the -0HART option turns the pass-through off.

Up to which SIL is the SSX approved?

Up to SIL 3 in monitor mode, where only the input circuit is part of the safety function, and up to SIL 2 in single use, under IEC 61508:2010.

Where does the SSX get its power?

From the output side of the loop, typically a DCS or PLC, at 12-42 Vdc.