The STA works as a logic solver in an emergency shutdown system for tank overfill protection, in place of a programmable safety controller. It is SIL 2/3 capable to IEC 61508, approved for installation in Class I Div 2 / Zone 2, and has a local display and an auxiliary 4–20 mA output.

Type
single-loop logic solver for SIS (functional signalling unit)
Functional safety
IEC 61508, SIL 3 capable
Loop level
SIL 2 / SIL 3
Approval for installation
Class I Div 2 / Zone 2

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Overfill protection is required for every tank that holds hydrocarbons. It is most often built as a safety instrumented system (SIS) made up of a level transmitter, a logic solver and a shut-off valve. The transmitter reports the level, the logic solver compares it with a set point, and once that point is exceeded the signal is removed and the valve stops the filling.

A programmable safety controller is often more than a single loop needs. The STA, a functional signalling unit for limit values, takes on the role of the SIS logic solver for one loop. It is simple to program, and the local display shows the value directly on the cabinet. The set point and trip logic can be configured without a separate safety controller programming environment.

Besides the discrete trip function, the STA offers an auxiliary analogue output of 4–20 mA that retransmits the measured value to a local RTU. In this way the operator sees the level in the telemetry system, while the safety function remains separate from the control system.

The device is certified to IEC 61508 as SIL 3 capable and suits SIL 2 and SIL 3 loops, with the assessment carried out by an independent functional safety body. The STA is approved for installation in Class I Div 2 / Zone 2 areas, with an ambient temperature range of -40 to 185 °F.

Beyond tank protection, the same unit is used as a logic solver in high-pressure separator protection and in temperature safety loops at oil and gas production sites.

Technical specifications

Typesingle-loop logic solver for SIS (functional signalling unit)
Functional safetyIEC 61508, SIL 3 capable
Loop levelSIL 2 / SIL 3
Approval for installationClass I Div 2 / Zone 2
Ambient temperature-40…185 °F
Auxiliary outputanalogue 4–20 mA
Indicationlocal display
Applicationtank overfill protection, SIS

Part numbers

Show all part numbers (1)

STA

Request a price and lead time

STA Single-Loop Logic Solver for Tank Overfill Protection, SIL 2/3. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can the STA replace the safety controller in a tank overfill loop?

Yes. For a single loop, the level transmitter, the STA and the shut-off valve form the SIS, and the device is SIL 2/3 capable to IEC 61508.

How is the level passed to the telemetry system?

Through the auxiliary 4–20 mA analogue output, which retransmits the value to the local RTU.

Can the STA be installed in an explosive atmosphere?

The device is approved for Class I Div 2 / Zone 2 areas, with an ambient temperature range from -40 to 185 °F.