ST75 thermal mass flow meters for air and gases, 1/4″ to 2″ pipe
The ST75 is a compact in-line thermal flow meter for direct mass flow measurement of air and gases. It has no moving parts, fits pipes from 1/4″ to 2″ [6 mm to 51 mm], offers turndown up to 100:1 and dual 4-20 mA outputs. HART or Modbus versions are available.
- Measuring principle
- Thermal dispersion, platinum RTD
- Pipe size
- 1/4″ to 2″ [6 mm to 51 mm]
- Flow range
- 0.01 SCFM to 559 SCFM [0,01 NCMH to 950 NCMH]
- Turndown
- factory set from 3:1 to 100:1
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
ST75 meters measure the mass flow of air, fuel gases and inert gases directly. They are built as an in-line spool piece with no moving parts, for pipes from 1/4″ to 2″ [6 mm to 51 mm]. Depending on pipe size the range runs from 0.01 SCFM to 559 SCFM [0,01 NCMH to 950 NCMH], with turndown set at the factory between 3:1 and 100:1. The instrument reports flow rate, totalised flow and temperature.
The sensing element is a precision platinum RTD in small-diameter, all-metal “equal-mass” thermowells. The probe is welded 316 stainless steel with Hastelloy-C22 thermowells. The V models (ST75V and ST75AV) carry Vortab® flow conditioners built into the spool piece for installations with limited straight run or flow in the transitional range. Their meter body is Schedule 40 stainless steel.
There are four versions. ST75 is the standard model, ST75V adds the Vortab conditioner, ST75A adds HART or Modbus with NAMUR-compliant 4-20 mA outputs and SIL compliance, and ST75AV combines both. Standard accuracy of ST75 and ST75A is ±2% of reading, ±0,5% of full scale, with ±1% of reading, ±0,5% of full scale as an option. ST75V and ST75AV are ±1% of reading, ±0,5% of full scale. Repeatability is ±0,5% of reading.
Every unit has two 4-20 mA outputs and a 500 Hz pulse output; ST75A and ST75AV add HART version 7 and Modbus RS485. Supply is 18 Vdc to 36 Vdc or 85 Vac to 265 Vac. The enclosure is rated NEMA 4X, IP66, IP67 and has two conduit entries, 1/2″ NPT or M20x1.5. The electronics can be mounted on the probe or remotely, at up to 50' [15 m] for ST75 and ST75V and up to 100' [30 m] for ST75A and ST75AV. Options include an LCD with 2 lines of 16 characters and extended temperature compensation from 0°F to 250°F.
Hazardous-area approvals cover FM, ATEX (II 2 G Ex db IIC T6...T1 Gb; II 2 D Ex tb IIIC T85°C...T300°C Db) and IECEx (Ex db IIC T6...T1 Gb; Ex tb IIIC T85°C...T300°C Db). ST75A and ST75AV meet SIL 1 under IEC 61508, with a safe failure fraction (SFF) of 78.5% to 81.1%.
Typical duties: fuel and air feed lines to burners and boilers, furnace, kiln and oven fuel and air control, natural gas sub-metering, chiller air flow, gas dosing and injection, heat-treatment gas control, air compressor monitoring, and fuel flow in co-generation and turbine generator plant.
Technical specifications
| Measuring principle | Thermal dispersion, platinum RTD |
|---|---|
| Pipe size | 1/4″ to 2″ [6 mm to 51 mm] |
| Flow range | 0.01 SCFM to 559 SCFM [0,01 NCMH to 950 NCMH] |
| Turndown | factory set from 3:1 to 100:1 |
| Media | air, compressed air, nitrogen, oxygen, argon, CO2, ozone, other inert gases, natural gas and other hydrocarbon gases |
| Process connection | T-fitting (NPT female): 1/4″, 1/2″, 3/4″, 1″, 1 1/2″ or 2″; tubing: 1/4″, 1/2″ or 1″ |
| Operating pressure | T-fitting: 240 psig [16,5 bar(g)]; tube: 600 psig [41 bar(g)] |
| Process temperature | 0°F to 250°F [-18°C to 121°C] |
| Electronics temperature | 0°F to 140°F [-18°C to 60°C] |
| Supply | 18 Vdc to 36 Vdc; 85 Vac to 265 Vac |
| Outputs | two 4-20 mA, 500 Hz pulse; ST75A, ST75AV: HART or Modbus RS485 |
| Accuracy | ST75, ST75A: ±2% of reading, ±0,5% of full scale (option ±1% of reading, ±0,5% of full scale); ST75V, ST75AV: ±1% of reading, ±0,5% of full scale |
| Repeatability | ±0,5% of reading |
| Enclosure rating | NEMA 4X, IP66, IP67 |
| Materials | 316 stainless steel, Hastelloy-C22 thermowells |
| Explosion protection | ATEX: II 2 G Ex db IIC T6...T1 Gb; II 2 D Ex tb IIIC T85°C...T300°C Db; IECEx: Ex db IIC T6...T1 Gb; Ex tb IIIC T85°C...T300°C Db |
| Functional safety | ST75A, ST75AV: SIL 1 (IEC 61508) |
Part numbers
Show all part numbers (4)
ST75, ST75V, ST75A, ST75AV
How it compares with similar models
| Parameter | ST75 thermal mass flow meters for air and gases, 1/4″ to 2″ pipe | Series 12400 digital displacer level and interface transmitter/controller, SIL 2 capable, ATEX | 8801B gas moisture monitor with wall-mounted display unit, -100 to 20 °C dew point | Explosion-Proof Trace Oxygen Analyser 3020T, Range from 0-10 ppm |
|---|---|---|---|---|
| Outputs | two 4-20 mA, 500 Hz pulse; ST75A, ST75AV: HART or Modbus RS485 | — | isolated 4–20 mA, relays 3 A 250 V AC / 30 V DC | 0-1 V DC and 4-20 mA DC, isolated |
| Accuracy | ST75, ST75A: ±2% of reading, ±0,5% of full scale (option ±1% of reading, ±0,5% of full scale); ST75V, ST75AV: ±1% of reading, ±0,5% of full scale | ±0.1 % (head alone), ±0.5 % (with torque tube), ±0.25 % on request; hysteresis + dead zone ±0.1 % / ±0.3 %; repeatability ±0.1 % / ±0.2 % | ±2 °C, temperature corrected | ±2% of span at constant temperature; ±5% across the operating range; ±1 ppm on the 0-10 ppm span |
Request a price and lead time
ST75 thermal mass flow meters for air and gases, 1/4″ to 2″ pipe. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which gases can the ST75 measure?
Air, compressed air, nitrogen, oxygen, argon, CO2, ozone, other inert gases, natural gas and other hydrocarbon gases.
What separates ST75, ST75V, ST75A and ST75AV?
The V suffix means a built-in Vortab flow conditioner; the A suffix means HART or Modbus, NAMUR-compliant 4-20 mA outputs and SIL compliance.
What pressure and temperature does the ST75 handle?
Operating pressure is up to 240 psig [16,5 bar(g)] with a T-fitting and up to 600 psig [41 bar(g)] with tubing; process temperature is 0°F to 250°F [-18°C to 121°C].