Explosion-Proof Trace Oxygen Analyser 3020T, Range from 0-10 ppm
The 3020T measures trace oxygen concentrations in hazardous areas using an electrochemical micro-fuel cell. It has three user-set ranges with automatic switching, a minimum span of 0-10 ppm, isolated 0-1 V and 4-20 mA outputs, and an explosion-proof enclosure for Class I, Division 1.
- Measuring principle
- micro-fuel element
- Ranges
- 3 programmable, minimum 0-10 ppm, automatic switching
- Calibration
- up to 0-25%
- Accuracy
- ±2% of span at constant temperature; ±5% across the operating range; ±1 ppm on the 0-10 ppm span
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Trace oxygen work is where this analyser earns its keep: inert blanketing, air separation and liquefaction, chemical reaction monitoring, semiconductor fabrication, petrochemical plants and gas quality control. It measures oxygen up to 20.9% in flammable and non-flammable gases, and it runs on gases of Group B up to and including IIB+H2, which covers hydrogen. For gases enriched with oxygen above 21%, the unit is not intended.
The sensing element is an L-2 grade micro-fuel cell with a service life of roughly two years in most applications. Other cell types, including L2C, B2C, A2C, A5, XL and Insta-Trace, are available. Sensitivity is 0.5% of span, and the response reaches 90% of span in under 65 seconds at 25 °C. Accuracy is ±2% of span at constant temperature and ±5% across the operating temperature range once the temperature has settled. On the 0-10 ppm span, accuracy is ±1 ppm.
The user sets three ranges, with a minimum of 0-10 ppm, and switching between them is automatic. Calibration can extend to 0-25%. Measurement and range-identification signals are both 0-1 V DC and 4-20 mA DC, isolated from each other. Two programmable concentration set points use changeover contacts rated 3 A, and a separate system failure signal also trips on loss of power. An RS-232C interface at 2400 baud passes all key parameters for remote monitoring. The display shows five digits in red LED, alongside a two-line, 20-character LCD.
The explosion-proof enclosure is listed by UL and CSA for Class I, Division 1, Groups B, C and D, with a NEMA 4/7 rating. The ATEX/IECEx version is marked II 2G Ex db IIB+H2 T6 Gb, holds certificates ITS17ATEX102893X and IECEx ETL 17.0067X, conforms to IEC 60079-0:2017 and IEC 60079-1:2014, and has IP 66 protection. Variants include the 3020T-C with integral zero and calibration valves, the 3020T-F and 3020T-G with flame arrestors for Groups C and D, the 3020T-H and 3020T-I with flame arrestors for hydrogen in Group B, and the 3020T-S with a stainless steel cell block.
Power is 115 or 230 V AC at 50 or 60 Hz, drawing up to 292 W. Operating temperature is 0-50 °C. Gas pressure must not exceed 25 psig (172 kPa), the sensor inlet is limited to 0.86 psig (6 kPa), and sample flow is up to 1100 SCCM. Gas connections are 1/4-inch fittings, and cable entries are 3/4-inch or 1-inch NPT. The enclosure measures 25.63 by 15.25 by 11 inches.
Technical specifications
| Measuring principle | micro-fuel element |
|---|---|
| Ranges | 3 programmable, minimum 0-10 ppm, automatic switching |
| Calibration | up to 0-25% |
| Accuracy | ±2% of span at constant temperature; ±5% across the operating range; ±1 ppm on the 0-10 ppm span |
| Sensitivity | 0.5% of span |
| Response time | 90% of span in under 65 s at 25 °C |
| Outputs | 0-1 V DC and 4-20 mA DC, isolated |
| Alarms | 2 set points, contacts rated 3 A; system failure signal |
| Interface | RS-232C, 2400 baud |
| Operating temperature | 0-50 °C |
| Power supply | 115/230 V AC, 50-60 Hz, up to 292 W |
| Explosion protection | Class I, Division 1, Groups B, C and D; NEMA 4/7; II 2G Ex db IIB+H2 T6 Gb |
| Ingress protection | IP 66 |
| Sample connection | 1/4-inch fittings |
| Dimensions (H x W x D) | 25.63 x 15.25 x 11 inches |
Part numbers
Show all part numbers (7)
3020T, 3020T-C, 3020T-F, 3020T-G, 3020T-H, 3020T-I, 3020T-S
Request a price and lead time
Explosion-Proof Trace Oxygen Analyser 3020T, Range from 0-10 ppm. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Can the 3020T measure in hydrogen-bearing gases?
Yes. The 3020T-H and 3020T-I have flame arrestors for Group B (hydrogen) service, and the ATEX/IECEx version is marked Ex db IIB+H2 T6 Gb.
What is the smallest range available?
0-10 ppm, with an accuracy of ±1 ppm on that span. Three ranges are set by the user, and the unit switches between them automatically.
How often does the sensor need replacing?
The class L-2 micro-fuel element is designed to last about two years in most applications, after which it is replaced.