8801T trace moisture transmitter, two-wire 4–20 mA loop powered, -100 to 20 °C dew point

A compact stainless steel transmitter that reports the dew point of a gas stream straight onto a 4–20 mA loop. It draws its power from that same two-wire loop at 5 to 28 V DC, so no separate supply cable is run to the sampling point.

Dew point range (output)
-100 to 20 °C
Sensor range
-110 to 20 °C
Accuracy
±2 °C, temperature corrected
Repeatability
0.8 °C

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

At the heart of the 8801T is a nanopore sensing element. Water vapour molecules diffuse into the pores, and the electronics read the resulting change in capacitance with a resolution of 1 pF, equivalent to less than 0.01 °C of dew point. The element itself covers -110 to 20 °C; the loop output is scaled to -100 to 20 °C. Accuracy is ±2 °C with temperature correction, repeatability is 0.8 °C, and the reading reaches 95 % of a step change within 3 minutes provided the sample flow exceeds 1 litre per minute.

Typical duties include natural gas conditioning, petrochemical plants, industrial gas production, power stations, compressed air dryers and heat treatment furnace atmospheres. Pharmaceutical, aerospace and medical installations use the same transmitter.

The housing is all stainless steel, with wetted parts in 316 stainless and PTFE. Installed, it is rated IP67; the five-pin M12 connector reaches IP68 once its mating plug is fully home. Process connection is by 3/4″-16 or 14 mm × 1.25 mm thread, with 1/4″ NPT available, and the body has flats for a spanner. It weighs 0.17 kg and is rated to 345 bar. The electronics tolerate -40 to 85 °C, while the sensor and analyser are specified for -20 to 60 °C.

Alongside the HART-enabled loop there is a digital input/output for driving relays. Order codes: 8801T.0 with a sintered stainless shield, 8801T.S with a solid shield for ultra-high-purity gases, 8801T.M adding two-wire RS-485 Modbus in ASCII or RTU, and 8801T.O2 with an oxygen-cleaned sensor. Readings can be shown in °C or °F dew point, ppmV, ppmW, H2O vapour pressure or g/m³. Calibration is NIST traceable. Where a local display is wanted, the panel-mounted 8801A or wall-mounted 8801B can be added.

Technical specifications

Dew point range (output)-100 to 20 °C
Sensor range-110 to 20 °C
Accuracy±2 °C, temperature corrected
Repeatability0.8 °C
Response time95 % of step change in 3 min
Sample flow> 1 l/min
Supply5–28 V DC, two-wire loop
Output4–20 mA with HART, optional Modbus RS-485
Wetted materials316 stainless steel, PTFE
ProtectionIP67 (enclosure), IP68 (M12 connector)
Process thread3/4″-16, 14 mm × 1.25 mm, optional 1/4″ NPT
Maximum pressure345 bar (5000 psia)
Electronics temperature-40 to 85 °C
Sensor temperature-20 to 60 °C
Weight0.17 kg

Request a price and lead time

8801T trace moisture transmitter, two-wire 4–20 mA loop powered, -100 to 20 °C dew point. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What dew point span does the 8801T cover?

The sensing element works from -110 to 20 °C dew point, and the 4–20 mA output is scaled to -100 to 20 °C.

Can the transmitter talk Modbus?

Yes, the 8801T.M version adds two-wire RS-485 Modbus in ASCII or RTU while keeping the 4–20 mA HART loop.

Which version suits ultra-high-purity or oxygen service?

Choose 8801T.S, which has a solid shield in place of the sintered filter, or 8801T.O2 with a sensor cleaned for oxygen.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides