496 Series Rotary Limit Switches and 4–20 mA Valve Position Transmitter, IP66/67
Valve-mounted switch boxes that report where a control valve stem sits in its stroke, either as discrete switch contacts or as a continuous 4–20 mA signal. Weatherproof, flameproof and intrinsically safe versions cover Zones 0, 1, 2, 20, 21 and 22.
- Types
- 496-1/2/6/7 microswitches; 496-4/5 proximity; 496-8 position transmitter
- Travel
- rotary up to 90°; linear 12–102 mm via linkage
- Microswitch rating
- 10 A at 300 V AC; 0.6 A at 24/30 V DC
- Output, 496-8
- 4–20 mA
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The model number tells you what is inside. Types 496-1 and 496-2 hold one or two single-pole double-throw microswitches, 496-6 and 496-7 one or two double-pole double-throw units, and 496-4 and 496-5 one or two proximity detectors. The 496-8 is an opto-electronic position transmitter. Each microswitch has silver-plated contacts and its own adjustable cam, and is rated 10 A at 300 V AC or 0.6 A at 24/30 V DC.
The 496-8 transmitter gives 4–20 mA from a 9–36 V DC supply in flameproof form, or 9–28 V DC when intrinsically safe. Linearity is within 0.5% between 25° and 60° of rotation and within 0.3% from 60° to 90°; hysteresis, dead band and repeatability are each 0.1% or better, and accuracy is 0.5% or better. Limit switches can be added to the transmitter.
The shaft turns through up to 90°. On reciprocating valves a linkage converts 12 mm to 102 mm of stem travel into rotation, and the order should state whether the travel is rotary or linear.
Body and cover are aluminium with anti-corrosion treatment and epoxy or polyurethane paint, with passivated 316L stainless steel as an option; the shaft is stainless, and no copper or copper-bearing alloy is exposed. Ingress protection is IP66/IP67 to EN 60529, and the ambient range is −50 °C to +80 °C. In the European numbering, protection code 55 means weatherproof, 57 flameproof for gas and dust, and 58 intrinsically safe. Gas and dust groups IIA, IIB, IIC and IIIC are covered under ATEX, FM and CSA approvals. Cable entries are 3/4 in NPT, 1/2 in NPT or M20 x 1.5.
Typical homes are control valves in power stations, refineries, petrochemical plants and upstream or midstream oil and gas.
Technical specifications
| Types | 496-1/2/6/7 microswitches; 496-4/5 proximity; 496-8 position transmitter |
|---|---|
| Travel | rotary up to 90°; linear 12–102 mm via linkage |
| Microswitch rating | 10 A at 300 V AC; 0.6 A at 24/30 V DC |
| Output, 496-8 | 4–20 mA |
| Supply, 496-8 | 9–36 V DC (flameproof); 9–28 V DC (intrinsically safe) |
| Linearity, 496-8 | ≤ 0.5% (25–60°); ≤ 0.3% (60–90°) |
| Accuracy, 496-8 | ≤ 0.5% |
| Ambient temperature | −50 to +80 °C |
| Ingress protection | IP66/IP67 to EN 60529 |
| Hazardous areas | ATEX, FM, CSA; groups IIA, IIB, IIC, IIIC; Zones 0, 1, 2, 20, 21, 22 |
| Housing material | coated aluminium; 316L stainless option |
| Cable entries | 3/4 in NPT, 1/2 in NPT, M20 x 1.5 |
Request a price and lead time
496 Series Rotary Limit Switches and 4–20 mA Valve Position Transmitter, IP66/67. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Will it fit a valve with a linear stem?
Yes, a linkage converts 12–102 mm of stem travel into shaft rotation; direct rotary travel is up to 90°.
What signal does the 496-8 transmitter give?
An analogue 4–20 mA output, powered at 9–36 V DC in flameproof form or 9–28 V DC when intrinsically safe, with accuracy of 0.5% or better.
Which hazardous areas is the series approved for?
Zones 0, 1, 2, 20, 21 and 22, gas and dust groups IIA, IIB, IIC and IIIC, under ATEX, FM and CSA.
Similar equipment from other manufacturers