SERIES 5750 Programmable Temperature Transmitter for Thermocouples and RTDs, 4-20 mA

The SERIES 5750 is a low-profile programmable signal conditioner for thermocouple or resistance thermometer (RTD) inputs. It mounts directly inside a DIN B or larger connection head and linearises the sensor signal into a 4-20 mA output.

Type
programmable signal conditioner for temperature
Input
thermocouple or resistance thermometer (RTD)
RTD connection
three-wire and four-wire
Output signal
4-20 mA

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The SERIES 5750 belongs to the range of temperature sensor accessories. It converts the signal from the primary sensor into a standard 4-20 mA current, which is passed on to a controller, recorder or control system. The manufacturer positions it as a way to improve the accuracy and stability of temperature measurement, which helps reduce downtime and maintenance costs.

The input accepts a thermocouple or a resistance temperature detector (RTD). For RTDs, three-wire and four-wire connections are supported, and both reduce the effect of lead resistance on the reading. The transmitter is programmed for the specific sensor type and the required measurement range.

The main function is linearisation. The output of a thermocouple or RTD does not change in a straight line with temperature, and the SERIES 5750 converts it into a linear 4-20 mA output. Once linearised, readings stay accurate across a wide temperature range, and the receiving equipment gets a signal that is proportional to temperature.

The housing has a low profile and is designed to sit directly inside a DIN B or larger connection head on the sensor. The transmitter sits at the measuring point, so the control cabinet receives a current signal rather than the weak raw signal from the sensor.

When ordering, specify the sensor type, the RTD connection scheme, the required temperature range and the head size. The transmitter is used with temperature sensors in heat treatment, power generation, environmental monitoring, semiconductor processing, clinical and laboratory equipment, food service equipment and life sciences.

Technical specifications

Typeprogrammable signal conditioner for temperature
Inputthermocouple or resistance thermometer (RTD)
RTD connectionthree-wire and four-wire
Output signal4-20 mA
Functionlinearisation of the sensor signal
Designlow-profile housing
MountingDIN B or larger connection head

Part numbers

Show all part numbers (1)

SERIES 5750

Request a price and lead time

SERIES 5750 Programmable Temperature Transmitter for Thermocouples and RTDs, 4-20 mA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which sensors can be connected to the SERIES 5750?

Thermocouples and resistance thermometers. For RTDs, three-wire and four-wire connections are supported.

Where is the transmitter installed?

Directly inside a DIN B or larger connection head on the sensor.

What output does the device give?

A linearised 4-20 mA current signal that is proportional to the measured temperature.