RotoPaq Thermal Profiling System for Rotational Moulding, TP6 and DP5 Loggers
The RotoPaq system records temperature in the oven, on the mould surface and inside the mould during heating and cooling cycles in rotational moulding of plastics. It is supplied as a Premium system with a 10-channel TP6 logger and as a Lite system with a 6-channel DP5 logger, measuring up to 1370 °C.
- Premium logger
- TP6116, 10 channels
- TP6 range
- -100 to 1370 °C
- TP6 accuracy
- ±0.3 °C (Type K)
- TP6 memory
- 4 million data points
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Rotational moulding is used to make domestic and industrial plastic products. The RotoPaq system monitors temperature across both phases of the process, heating and cooling. Data is taken directly in the oven, on the mould surface or inside the mould, which reveals the phase transitions of the polymer. From the profile the process engineer adjusts the process parameters and cycle duration, takes account of changing external conditions, and checks new materials and settings.
The system consists of a data logger, a thermal barrier, thermocouples and analysis software. The barrier is clamped to the mould and turns with it, protecting the logger from oven heat. After a run, the data is read to a PC over USB or Bluetooth.
The Premium version is built on the TP6116 logger, which has 10 channels, a range from -100 to 1370 °C, an accuracy of ±0.3 °C for Type K thermocouples and a resolution of ±0.1 °C, with a memory of 4 million data points. Its body is machined from 316 stainless steel and rated IP67. The sampling interval runs from 0.2 s to 50 min, and with radio telemetry from 2 s to 50 min, in which case the profile can be viewed on a PC during the process. Alkaline, NiMH and lithium batteries are supported.
The Lite version uses the DP5660 logger with 6 channels, a range from -200 to 1370 °C, an accuracy of ±0.5 °C and a memory of 50,000 readings per channel. The shortest sampling interval is 0.05 s, and the NiMH battery is replaced by the user. Recording is started by the Start/Stop buttons, by time or by temperature, and up to 10 profiles can be recorded before returning to the PC. Type K thermocouples are standard, with B, S, R, T, N and J types also available.
Thermal barriers with mounting brackets are supplied. The TB5000-RP is waterproof, weighs 6.2 kg, and its endurance at 100 °C is 14.5 hours. The TB5018-RP (8.3 kg) and TB5811 (7.8 kg) each endure 150 °C for 8 hours. The TB5012-RP is built from stainless steel for the DP5660, and it weighs 8.4 kg. Its endurance reads 11.5 hours when held at 100 °C, 6.5 hours at 150 °C and 3 hours at 300 °C.
Technical specifications
| Premium logger | TP6116, 10 channels |
|---|---|
| TP6 range | -100 to 1370 °C |
| TP6 accuracy | ±0.3 °C (Type K) |
| TP6 memory | 4 million data points |
| TP6 sampling interval | 0.2 s – 50 min, with telemetry 2 s – 50 min |
| TP6 housing | 316 stainless steel, IP67 |
| Lite logger | DP5660, 6 channels |
| DP5 range | -200 to 1370 °C |
| DP5 accuracy | ±0.5 °C |
| DP5 memory | 50,000 readings per channel |
| Resolution | ±0.1 °C |
| Thermocouples | Type K standard; B, S, R, T, N and J also available |
| Communication | USB, Bluetooth |
| Barrier TB5000-RP | 6.2 kg, 14.5 h at 100 °C |
| Barrier TB5012-RP | 11.5 h at 100 °C, 8.4 kg |
Part numbers
Show all part numbers (7)
TP6116, TP6116-TM, DP5660, TB5000-RP, TB5018-RP, TB5811, TB5012-RP
Request a price and lead time
RotoPaq Thermal Profiling System for Rotational Moulding, TP6 and DP5 Loggers. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How do the Premium and Lite versions differ?
Premium has a 10-channel TP6 logger with ±0.3 °C accuracy, 4 million data points and radio telemetry. Lite uses a 6-channel DP5660 logger with ±0.5 °C accuracy.
Can I see the temperature during a cycle?
Yes. In the Premium version with radio telemetry the profile is sent to a PC in real time, with a sampling interval from 2 s.
How long does the logger survive in the oven?
It depends on the barrier and the temperature. The TB5000-RP is rated for 14.5 hours when held at 100 °C, and the TB5018-RP and TB5811 last 8 hours each at 150 °C.
Similar equipment from other manufacturers