Ranarex 388 Portable Gas Gravitometer for Relative Gas Density, 0.52 to 1.90 Range

A portable electromechanical gravitometer that measures the relative density of a process gas against air. It has two scales, 0.52 to 1.03 and 0.97 to 1.90, with an accuracy of ±0.5% of the actual value, and follows the ASTM D1070 method for gaseous fuels.

Measured parameter
relative density of gas against air
Range
two scales, 0.52 to 1.03 and 0.97 to 1.90
Accuracy
±0.5% of the actual value
Readout
indication only

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The gravitometer is used to check the composition and quality of gas mixtures in hydrocarbon processing and the gas sector. Typical tasks include custody metering, transport and blending of natural gas, separation of gas condensate and LPG, recycle gases in refineries and catalytic reforming, combustion analysis, fuel gas systems, sewage treatment gases and petroleum off gases. It can also measure dry SO2, dry NH3 and wet or dry H2S, and it covers hydrogen in ammonia production, coke oven and water gas, and producer gases at metallurgical and chemical plants.

The body forms two cylindrical gas-tight measuring chambers, each with its own inlet and outlet. Each chamber holds an impeller and a pulse wheel with axial vanes. An electric motor drives a belt that turns both impellers at the same speed in the same direction, with sample gas going into the upper chamber and reference air into the lower one. The swirling flow creates torques proportional to the density of the gas and of the air. Through the measuring wheels and a cross-wound flexible tape, the system divides the gas torque by the air torque, and this ratio equals the relative density.

The reading is instantaneous, and no chemical reaction or gas diffusion is needed for the measurement. The range does not drift and zero drift is minimal. The jewel bearings and permanently lubricated bearings wear slowly and need almost no maintenance. The mechanical parts resist corrosion, and the instrument has no glass or electronic components.

The instrument can stand on the floor, on a bench or be mounted on a wall. The motor runs from 115 VAC at 60 Hz or 230 VAC at 50 Hz, and in the field it can run from a 12 V car battery through a DC-AC inverter. Installation needs only the piping and a power supply. Sample flow is 15-20 SCFH when stationary and 10-15 SCFH when portable, with inlet pressure up to 20 psig. The reference air is dried with silica gel that changes from blue to pink, and a built-in flowmeter shows the sample flow.

When gas pressure exceeds 100 PSIG or the temperature difference between gas and air is more than 10 °F, the sample passes through a heat exchanger tube 3 metres long and 3/8 inch in diameter. A moisture trap and a 25 micron filter clean the sample.

Technical specifications

Measured parameterrelative density of gas against air
Rangetwo scales, 0.52 to 1.03 and 0.97 to 1.90
Accuracy±0.5% of the actual value
Readoutindication only
Drive motor115 VAC, 60 Hz or 230 VAC, 50 Hz
Sample flow15-20 SCFH (stationary), 10-15 SCFH (portable)
Sample pressureup to 20 psig
Reference air dryersilica gel
Flowmeterbuilt in
Weight20.9 kg (220v model), 17.2 kg (115v model)
Shipping weight22.7 kg (50 lb)
StandardASTM D1070

Part numbers

Show all part numbers (2)

CH300-27404, CH300-28656

Request a price and lead time

Ranarex 388 Portable Gas Gravitometer for Relative Gas Density, 0.52 to 1.90 Range. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can the gravitometer run in the field without mains power?

Yes. It can run from a 12 V car battery through a DC-AC inverter, either the CH300-27404 at 12 VDC/115 VAC, 500 W, or the CH300-28656 at 12 VDC/230 VAC, 1000 W.

What density range does the instrument measure?

It has two scales, 0.52 to 1.03 and 0.97 to 1.90, with an accuracy of ±0.5% of the actual value.

Does high-pressure gas need conditioning before measurement?

Yes. Above 100 PSIG, or when the temperature difference exceeds 10 °F, the sample passes through a heat exchanger tube 3 metres long, and the inlet pressure must stay at or below 20 psig.