International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

PWV combined watt/VAR transducer for RMS active and reactive power

The PWV is a combined-function unit that calculates both RMS active power and RMS reactive power. The PWV/69AC,5A/4-20mA/3E [DM] model takes 69 V AC and 5 A, gives 4 to 20 mA, has three elements for a 3-phase, 4-wire system and fits DIN rail.

Model
PWV/69AC,5A/4-20mA/3E [DM]
Type
Watt/VAR transducer
Measured quantities
RMS active and reactive power
Voltage input
69 V AC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The PWV is a Watt/VAR transducer, a combined-function unit that calculates both RMS active power and RMS reactive power. One unit can therefore stand in for two separate transducers when both quantities are needed to judge a load.

The PWV/69AC,5A/4-20mA/3E [DM] model has a 69 V AC voltage input, a 5 A current input and a 4 to 20 mA output. It uses a 3-element arrangement for 3-phase, 4-wire systems and is self powered.

The housing is made for DIN-rail mounting (DM). No 2-inch pipe-mount bracket is provided.

The 4 to 20 mA output can be fed to data acquisition systems and controllers as a signal proportional to power.

The 69 V AC and 5 A inputs are set by the model code, and the 4 to 20 mA output passes the measured value to a controller or recorder.

Technical specifications

ModelPWV/69AC,5A/4-20mA/3E [DM]
TypeWatt/VAR transducer
Measured quantitiesRMS active and reactive power
Voltage input69 V AC
Current input5 A
Output4 to 20 mA
Measurement elements3 elements, 3-phase, 4-wire
PowerSelf powered
HousingDIN rail (DM)
2-inch pipe-mount bracketNo
CertificationUL Approved

Part numbers

Show all part numbers (2)

PWV/69AC, 5A/4-20mA/3E [DM]

How it compares with similar models

ParameterPWV combined watt/VAR transducer for RMS active and reactive powerPVT VAR transducer for RMS reactive power, 4-20MAB outputPWT AC watt transducer for RMS active power, 4 to 20 mA outputPAV AC voltage transducer, 0 to 90 V AC input, 0 to 1 mA output
TypeWatt/VAR transducerVAR transducer, RMS reactive powerAC watt transducer, RMS active powerAC voltage transducer, single configuration
Voltage input69 V AC120 V AC120 V AC—
Output4 to 20 mA4-20MAB4 to 20 mA0 to 1 mA DC
Measurement elements3 elements, 3-phase, 4-wire2 elements, 3-phase, 3-wire2 elements, 3-phase, 3-wire—
HousingDIN rail (DM)Surface mount (SM), aluminiumSurface mount (SM), extruded aluminiumDIN rail (DM)

Request a price and lead time

PWV combined watt/VAR transducer for RMS active and reactive power. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What does the PWV calculate?

Both RMS active power and RMS reactive power in one unit.

Which network does this model suit?

A 3-phase, 4-wire system, with 3 elements and 69 V AC and 5 A inputs.

What is its output?

4 to 20 mA.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides