International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

PWT AC watt transducer for RMS active power, 4 to 20 mA output

The PWT monitors RMS active power and reports it in watts. The PWT/120AC,5A/4-20mA/2E [SM] model takes 120 V AC and 5 A, gives 4 to 20 mA, has two elements for a 3-phase, 3-wire system and is powered from the measured circuit.

Model
PWT/120AC,5A/4-20mA/2E [SM]
Type
AC watt transducer, RMS active power
Voltage input
120 V AC
Current input
5 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The PWT continuously tracks the amount of power consumed by an electric device or system and reads it as RMS (root mean square) active power in watts. It gives a proportional milliamp output for judging equipment power use and operating efficiency.

The PWT/120AC,5A/4-20mA/2E [SM] model has a 120 V AC voltage input, a 5 A current input and a 4 to 20 mA output. It uses a 2-element measurement arrangement for 3-phase, 3-wire systems. It is self powered, drawing its operating energy from the measured circuit, and comes in a surface-mount housing (SM).

True RMS values of voltage and current are measured, so the watt reading is computed with high accuracy: ±0.2% of reading. Full input to output isolation removes the errors that ground loops introduce. Output ripple stays below 0.5% of full scale, and the response time is below 100 ms to 90% and below 200 ms to 99%.

The housing is rustproof extruded aluminium that sheds heat well. Keyhole cut-outs let the unit be taken off and refitted just by loosening the screws, and all circuitry is attached to the front panel so the boards slide out without removing the whole case.

The ambient range is -20 °C to +70 °C, the operating frequency is 60 Hz as standard, and the dielectric test is 2000 V RMS for one minute. The unit is UL approved.

Technical specifications

ModelPWT/120AC,5A/4-20mA/2E [SM]
TypeAC watt transducer, RMS active power
Voltage input120 V AC
Current input5 A
Output4 to 20 mA
Measurement elements2 elements, 3-phase, 3-wire
Power sourceSelf powered from the measured circuit
HousingSurface mount (SM), extruded aluminium
Accuracy±0.2% of reading
Operating frequency60 Hz standard
Ambient range-20 °C to +70 °C
Dielectric test2000 V RMS for one minute
Response timeTo 90% below 100 ms; to 99% below 200 ms
CertificationUL Approved

Part numbers

Show all part numbers (2)

PWT/120AC, 5A/4-20mA/2E [SM]

How it compares with similar models

ParameterPWT AC watt transducer for RMS active power, 4 to 20 mA outputPVT VAR transducer for RMS reactive power, 4-20MAB outputPAC AC current transducer, 1 A input, 0 to 1 mA DC outputPWV combined watt/VAR transducer for RMS active and reactive power
TypeAC watt transducer, RMS active powerVAR transducer, RMS reactive powerAC current transducer, single configurationWatt/VAR transducer
Voltage input120 V AC120 V AC—69 V AC
Output4 to 20 mA4-20MAB0 to 1 mA DC4 to 20 mA
Measurement elements2 elements, 3-phase, 3-wire2 elements, 3-phase, 3-wire—3 elements, 3-phase, 4-wire
HousingSurface mount (SM), extruded aluminiumSurface mount (SM), aluminiumDIN rail (DM), extruded aluminiumDIN rail (DM)

Request a price and lead time

PWT AC watt transducer for RMS active power, 4 to 20 mA output. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What does the PWT measure?

RMS active power of an AC circuit in watts, with a 4 to 20 mA output.

Which network does this model suit?

A 3-phase, 3-wire system, with 2 measurement elements, 120 V AC and 5 A inputs.

Does it need a separate supply?

No, it is self powered from the measured circuit.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides