PAV AC voltage transducer, 0 to 90 V AC input, 0 to 1 mA output

The PAV accepts an AC voltage input and returns a DC current output accurate to ±0.25% of rated output. The PAV/0-90AC/0-1mA/S [DM] model has a 0 to 90 V AC input, a 0 to 1 mA output, self-powered operation and a DIN-rail housing.

Model
PAV/0-90AC/0-1mA/S [DM]
Type
AC voltage transducer, single configuration
Input
0 to 90 V AC
Output
0 to 1 mA DC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The PAV AC voltage transducer accepts an AC voltage input and provides a highly accurate DC current output, ±0.25% of rated output.

The PAV/0-90AC/0-1mA/S [DM] model has a 0 to 90 V AC input and a 0 to 1 mA output. It is self powered (S), taking its energy from the measured circuit, and uses a DIN-rail housing (DM). The type in the table is AC Voltage Transducer (Single).

The series has 97 versions. Input ranges in it are 0 to 90, 0 to 150, 0 to 300, 0 to 600, 90 to 150, 100 to 140, 110 to 130, 180 to 300, 200 to 280 and 220 to 260 V AC. Output signals are 0 to 1 mA, 4 to 20 mA, 1 to 5 V and 0 to 50 mV. The codes include the suffixes S and T, as well as -120AC, -240AC and -240AC-50HZ.

Every version is supplied in two housings, [DM] for DIN rail and [SM] for surface mounting.

The approval is UL Approved. No 2-inch pipe-mount bracket is included.

Technical specifications

ModelPAV/0-90AC/0-1mA/S [DM]
TypeAC voltage transducer, single configuration
Input0 to 90 V AC
Output0 to 1 mA DC
PowerSelf powered
HousingDIN rail (DM)
Accuracy±0.25% of rated output
2-inch pipe-mount bracketNo
CertificationUL Approved

Part numbers

Show all part numbers (3)

PAV/0-90AC/0-1mA/S [DM], 97 versions in total, including PAV/0-90AC/0-1mA/S [SM]

How it compares with similar models

ParameterPAV AC voltage transducer, 0 to 90 V AC input, 0 to 1 mA outputPAC AC current transducer, 1 A input, 0 to 1 mA DC outputPWV combined watt/VAR transducer for RMS active and reactive powerPVT VAR transducer for RMS reactive power, 4-20MAB output
TypeAC voltage transducer, single configurationAC current transducer, single configurationWatt/VAR transducerVAR transducer, RMS reactive power
Output0 to 1 mA DC0 to 1 mA DC4 to 20 mA4-20MAB
HousingDIN rail (DM)DIN rail (DM), extruded aluminiumDIN rail (DM)Surface mount (SM), aluminium

Request a price and lead time

PAV AC voltage transducer, 0 to 90 V AC input, 0 to 1 mA output. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How accurate is the PAV?

±0.25% of rated output.

Which output signals are offered?

0 to 1 mA, 4 to 20 mA, 1 to 5 V and 0 to 50 mV.

Which housings are available?

[DM] for DIN rail and [SM] for surface mounting.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides