PAV AC voltage transducer, 0 to 90 V AC input, 0 to 1 mA output
The PAV accepts an AC voltage input and returns a DC current output accurate to ±0.25% of rated output. The PAV/0-90AC/0-1mA/S [DM] model has a 0 to 90 V AC input, a 0 to 1 mA output, self-powered operation and a DIN-rail housing.
- Model
- PAV/0-90AC/0-1mA/S [DM]
- Type
- AC voltage transducer, single configuration
- Input
- 0 to 90 V AC
- Output
- 0 to 1 mA DC
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The PAV AC voltage transducer accepts an AC voltage input and provides a highly accurate DC current output, ±0.25% of rated output.
The PAV/0-90AC/0-1mA/S [DM] model has a 0 to 90 V AC input and a 0 to 1 mA output. It is self powered (S), taking its energy from the measured circuit, and uses a DIN-rail housing (DM). The type in the table is AC Voltage Transducer (Single).
The series has 97 versions. Input ranges in it are 0 to 90, 0 to 150, 0 to 300, 0 to 600, 90 to 150, 100 to 140, 110 to 130, 180 to 300, 200 to 280 and 220 to 260 V AC. Output signals are 0 to 1 mA, 4 to 20 mA, 1 to 5 V and 0 to 50 mV. The codes include the suffixes S and T, as well as -120AC, -240AC and -240AC-50HZ.
Every version is supplied in two housings, [DM] for DIN rail and [SM] for surface mounting.
The approval is UL Approved. No 2-inch pipe-mount bracket is included.
Technical specifications
| Model | PAV/0-90AC/0-1mA/S [DM] |
|---|---|
| Type | AC voltage transducer, single configuration |
| Input | 0 to 90 V AC |
| Output | 0 to 1 mA DC |
| Power | Self powered |
| Housing | DIN rail (DM) |
| Accuracy | ±0.25% of rated output |
| 2-inch pipe-mount bracket | No |
| Certification | UL Approved |
Part numbers
Show all part numbers (3)
PAV/0-90AC/0-1mA/S [DM], 97 versions in total, including PAV/0-90AC/0-1mA/S [SM]
How it compares with similar models
| Parameter | PAV AC voltage transducer, 0 to 90 V AC input, 0 to 1 mA output | PAC AC current transducer, 1 A input, 0 to 1 mA DC output | PWV combined watt/VAR transducer for RMS active and reactive power | PVT VAR transducer for RMS reactive power, 4-20MAB output |
|---|---|---|---|---|
| Type | AC voltage transducer, single configuration | AC current transducer, single configuration | Watt/VAR transducer | VAR transducer, RMS reactive power |
| Output | 0 to 1 mA DC | 0 to 1 mA DC | 4 to 20 mA | 4-20MAB |
| Housing | DIN rail (DM) | DIN rail (DM), extruded aluminium | DIN rail (DM) | Surface mount (SM), aluminium |
Request a price and lead time
PAV AC voltage transducer, 0 to 90 V AC input, 0 to 1 mA output. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How accurate is the PAV?
±0.25% of rated output.
Which output signals are offered?
0 to 1 mA, 4 to 20 mA, 1 to 5 V and 0 to 50 mV.
Which housings are available?
[DM] for DIN rail and [SM] for surface mounting.
Similar equipment from other manufacturers