International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

PAC AC current transducer, 1 A input, 0 to 1 mA DC output

The PAC accepts an AC current input and returns a DC current output accurate to ±0.25% of rated output. The PAC/1A/0-1mA/S [DM] model has a 1 A input, a 0 to 1 mA output, self-powered operation and a DIN-rail housing.

Model
PAC/1A/0-1mA/S [DM]
Type
AC current transducer, single configuration
Input
1 A AC
Output
0 to 1 mA DC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The PAC AC current transducer accepts an AC current input and provides a highly accurate DC current output, ±0.25% of rated output. It responds to the average value of the input signal and is calibrated to indicate the RMS value.

The PAC/1A/0-1mA/S [DM] model is a single-configuration unit with a 1 A input and a 0 to 1 mA output. It is self powered, deriving its energy from the monitored circuit, and sits in a DIN-rail housing (DM). Single models are also offered with auxiliary power from an external source, and triple-channel versions share one housing.

The transducer monitors the electrical consumption of load devices such as motors and heaters, measures the output of source devices such as transformers and generators, and can trigger an alarm when the current leaves a safe range. Surge limiters protect both the input and the output.

The housing is rustproof extruded aluminium with keyhole cut-outs for removal by loosening the screws. Multiturn potentiometers set the adjustments: span ±10% of rated output and zero ±2% (4 to 20 mA output), or +2% and 0% with a 1 mA output. A single-configuration unit weighs 295 g.

The ambient range is -20 °C to +70 °C, the frequency is 60 Hz and the dielectric test is 2000 V RMS for one minute. Response time is below 200 ms to 90% and below 400 ms to 99%. The self-powered burden is 0.5 VA.

Technical specifications

ModelPAC/1A/0-1mA/S [DM]
TypeAC current transducer, single configuration
Input1 A AC
Output0 to 1 mA DC
PowerSelf powered
HousingDIN rail (DM), extruded aluminium
Accuracy±0.25% of rated output
Frequency60 Hz
Self-powered burden0.5 VA
Ambient range-20 °C to +70 °C
Response timeTo 90% below 200 ms; to 99% below 400 ms
Dielectric test2000 V RMS for one minute
Weight, single configuration295 g
CertificationUL Approved

Part numbers

Show all part numbers (1)

PAC/1A/0-1mA/S [DM]

How it compares with similar models

ParameterPAC AC current transducer, 1 A input, 0 to 1 mA DC outputPAV AC voltage transducer, 0 to 90 V AC input, 0 to 1 mA outputPWT AC watt transducer for RMS active power, 4 to 20 mA outputPVT VAR transducer for RMS reactive power, 4-20MAB output
TypeAC current transducer, single configurationAC voltage transducer, single configurationAC watt transducer, RMS active powerVAR transducer, RMS reactive power
Output0 to 1 mA DC0 to 1 mA DC4 to 20 mA4-20MAB
HousingDIN rail (DM), extruded aluminiumDIN rail (DM)Surface mount (SM), extruded aluminiumSurface mount (SM), aluminium
Accuracy±0.25% of rated output±0.25% of rated output±0.2% of reading—

Request a price and lead time

PAC AC current transducer, 1 A input, 0 to 1 mA DC output. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How accurate is the PAC?

±0.25% of rated output.

Does it need a separate supply?

No, the S version is self powered from the monitored circuit.

Which other configurations exist?

Single and triple; single models are also offered with auxiliary power.