PreMix 2000 analyser for excess O2 and excess fuel in premix burners

The stationary analyser measures excess oxygen or excess fuel in the air/fuel mixture before it reaches the burner. A zirconium oxide cell works in both oxidising and reducing mixtures, so one sensor shows which kind of mixture is present. The unit is intended for permanent installation in premix burner processes.

Measurement principle
zirconium oxide cell
Range
from 100% to 0.1% excess O2 and from 0.1% to 50% excess fuel
Accuracy O2
± 2% of reading or ± 0.1% O2, whichever is greater
Accuracy fuel
± 5% of reading or 0.25% excess fuel, whichever is greater

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The PreMix 2000 gives a continuous reading of the air/fuel ratio at premix burner stations, where a sample cannot be taken to a conventional flue gas analyser. Typical sites include glass forehearths and melting tanks, glass fibre apparatus, open flame brazing and soldering, flame treating, heat treatment of metals and ceramics, wire manufacturing, decarburising furnaces, ore roasting ovens and the primary stage of low NOx burners.

A small sample is drawn off, burnt, and the residual oxygen or excess fuel is measured. The sensing element is a zirconium oxide cell, and in oxidising mixtures its signal runs from 0 to about 130 mV. With excess fuel the signal climbs from about 550 mV to above 1000 mV, so one sensor shows whether the mixture is oxidising or reducing. Most of the flow goes through a bypass flow meter of up to 50 L/min, which shortens the response time and flushes stagnant volume from the inlet, while 0.5 L/min passes through the cell.

The sensor works with the Series 2000 microprocessor control unit. Its four-line, 20-character vacuum fluorescent display shows the readings, and the unit has two isolated current outputs that can be scaled freely. Either output can carry excess O2, excess fuel, a combined O2 and fuel scale, combustibles, the air/fuel ratio, cell temperature, or thermocouple or cell millivolts. The fuel type is picked from a list, or for a non-standard fuel the H/C ratio is entered, and the unit works out the calibration gas mix. Two independent alarms can each be set high or low.

The sensor is rated for ambient temperatures from -20 to 70 °C and has a UL Type 3R (IP14) enclosure. The control unit runs from -10 to 50 °C at 10% to 90% relative humidity without condensation. Its standard NEMA 4 (IP 56) enclosure suits wall or panel mounting, with general purpose wall, 19-inch rack and panel options, and a stainless steel NEMA 4X version. The sensor mounts on a panel, a wall or a pole. The portable CMFA-P 2000 holds the sensor and a Series 2000 control unit in a luggage-style case.

Technical specifications

Measurement principlezirconium oxide cell
Rangefrom 100% to 0.1% excess O2 and from 0.1% to 50% excess fuel
Accuracy O2± 2% of reading or ± 0.1% O2, whichever is greater
Accuracy fuel± 5% of reading or 0.25% excess fuel, whichever is greater
Repeatability± 0.2% of reading
Sensor flow0.5 L/min
Bypass flowup to 50 L/min
Sample pressurenot over 10 psig
Sensor ambient temperature-20 to 70 °C
Sensor power115 VAC ± 10%, 1200 VA max; 230 VAC ± 10%, 2400 VA max
Sensor enclosureUL Type 3R (IP14)
Analogue outputstwo isolated, 4-20 / 0-20 / 20-4 / 20-0 mA, load up to 1200 ohms
Alarmstwo independent, high or low, contacts 0.5 A, 30 V, 10 VA
CommunicationsRS-485, addressable, two-way
Control unit ambient temperature-10 to 50 °C
Control unit power115-230 VAC ± 10%, 47-63 Hz, 75 VA max
Control unit enclosureNEMA 4 (IP 56); optional NEMA 4X (IP 56)
Sample inlet1/4 inch compression fitting

Request a price and lead time

PreMix 2000 analyser for excess O2 and excess fuel in premix burners. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the analyser work in a reducing atmosphere?

Yes. It measures excess fuel in the range 0.1–50%, and in that mode the cell signal runs from about 550 mV to above 1000 mV.

Which signals does the control unit provide?

Two isolated current outputs of 4-20, 0-20, 20-4 or 20-0 mA into loads up to 1200 ohms, two alarm contacts rated 0.5 A at 30 V, and an RS-485 interface.

Is there a portable version?

Yes. The CMFA-P 2000 houses the sensor and the Series 2000 control unit in a luggage-style case, and it can measure both the mixture feeding a burner and flue gases.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides