NCS remote I/O system with up to 128 points per station, RS-485 Modbus RTU
The NCS gathers signals spread across process plants and passes them to a monitoring system over Modbus RTU. One station handles up to 128 points, and up to 32 systems can share a single twisted pair without repeaters.
- Type
- Remote I/O system
- Points per station
- Up to 128
- Input types
- RTD, TC, resistance, potentiometer, mV, mA, V
- Interface
- RS-485
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
NCS remote I/O systems are used at power stations, water supply and wastewater treatment sites, and pulp and paper mills. Measuring points on such sites are often added after commissioning, when the spare channels in the distributed control system have run out or no free twisted pairs remain in the cable routes. NCS collects signals from several process units or remote sites without the need to run new multicore cables back to the control room.
A station accepts thermocouple, RTD, resistance, potentiometer, millivolt, milliamp and voltage signals, with up to 128 points on each station. One cabinet on site therefore replaces dozens of separate lines. The channels are isolated from each other by 500V, which keeps measurements from interfering with one another and protects them from potential differences between field instruments.
Communication with the host runs over RS-485 using Modbus RTU. Up to 32 NCS systems can be connected multidrop to one twisted pair without repeaters, and they send their data to a monitoring host that acts as the Modbus master. Adding points means fitting another station on the same communication line. Configuration is straightforward, and new points do not require changes to the distributed control system.
The system is approved for Class I Div 2 and Zone 2 hazardous areas and is rated for ambient temperatures from -40 to 85C (-40 to 185F). This allows stations to be mounted directly on the plant, in unheated enclosures or on open sites.
Technical specifications
| Type | Remote I/O system |
|---|---|
| Points per station | Up to 128 |
| Input types | RTD, TC, resistance, potentiometer, mV, mA, V |
| Interface | RS-485 |
| Protocol | Modbus RTU |
| Systems on one twisted pair | Up to 32 without repeaters |
| Isolation | 500V between channels |
| Ambient temperature | -40...85C (-40...185F) |
| Hazardous area rating | Class I Div 2 / Zone 2 |
| Industries | Power generation, water supply and wastewater, pulp and paper |
Part numbers
Show all part numbers (1)
NCS
Request a price and lead time
NCS remote I/O system with up to 128 points per station, RS-485 Modbus RTU. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How many signals can one NCS station take?
Up to 128 I/O points per station, with RTD, TC, resistance, potentiometer, mV, mA and V inputs.
How many stations can share one communication line?
Up to 32 NCS systems can share one RS-485 twisted pair without repeaters, communicating over Modbus RTU.
Can the NCS be installed on an outdoor site?
Yes, the ambient operating range is -40 to 85C, and the system is approved for Class I Div 2 and Zone 2 areas.