Model 141 Linear Accelerometer with High-Level Output, ±2 to ±600 g

The Model 141 linear accelerometer delivers a DC signal proportional to acceleration, from static up to 3000 Hz. It uses a capacitive sensing element with gas damping at 0.7 of critical, a stainless steel housing with an O-ring seal, and ranges from ±2 to ±600 g.

Ranges
±2, ±4, ±8, ±15, ±30, ±60, ±150, ±600 g
Frequency range
static up to 3000 Hz
Overload
2000 g static
Non-linearity
±1.0% FS

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

This accelerometer measures linear acceleration from static up to around 3000 Hz and gives a high-level instantaneous DC output. The capacitive sensor and miniature electronics withstand a static overload of 2000 g without damage. Electrical characteristics are compatible with standard strain gauge amplifiers, including shunt calibration Rcal up to 100% of the nominal range.

Damping is gas-based, of the compressed-film type, at 0.7 ±0.2 of critical at 77 °F (25 °C), and the coefficient rises by about 0.15% per °F. Its temperature dependence is roughly ten times smaller than that of liquid damping. The frequency response is flat from static acceleration to about 60% of the natural frequency on all ranges, and transverse sensitivity does not exceed ±0.012 g/g.

The series includes ranges of ±2, ±4, ±8, ±15, ±30, ±60, ±150 and ±600 g, in two supply options. The BT code runs from 5 to 15 V DC, is calibrated at 10 V and draws 5 mA, with a nominal output of ±500 mV. The 2S code runs from 10 to 28 V DC, is calibrated at 24 V and draws 10 mA, with a ±1000 mV output. That version can run from an onboard 28 V DC supply, with overvoltage protection to MIL-STD-704A. The output impedance is 9 kΩ, and the zero output is below ±25 mV.

Non-linearity is ±1.0% FS, hysteresis 0.10%, and non-repeatability 0.05%. Zero and sensitivity shift are below ±0.02% of nominal range per °F. The operating temperature runs from -23 to +65 °C. The three-wire circuit is capacitively isolated from the case, with insulation resistance of 100 MΩ. Power applied to the output or a short on the output does not damage the circuit, but there is no reverse polarity protection, so a zener diode on the supply input is recommended, for example IN4746A for 141A and IN4752 for 141B. Exceeding 15 V DC for 141A or 28 V DC for 141B will destroy the circuit.

The stainless steel housing is sealed with an O-ring and has a clearly defined base plane that is little affected by mounting distortion. It is fixed with four No. 4-40 UNC screws through four holes. The 2-foot cable disconnects and can be replaced without removing the unit. Each unit is calibrated on a centrifuge at its specified supply voltage and shipped with an acceleration-to-output graph. It weighs 30 g without the cable, and an optional EMI filter is available.

Technical specifications

Ranges±2, ±4, ±8, ±15, ±30, ±60, ±150, ±600 g
Frequency rangestatic up to 3000 Hz
Overload2000 g static
Non-linearity±1.0% FS
Hysteresis0.10%
Non-repeatability0.05%
Zero and sensitivity shift<±0.02% of range/°F (<±0.36%/°C)
Transverse sensitivity<±0.012 g/g
Damping0.7 of critical, gas
Supply BT / 2S5–15 V DC / 10–28 V DC
Calibrated supply voltage10 V DC / 24 V DC
Supply current5 mA / 10 mA
Nominal output±500 mV at 10 V / ±1000 mV at 24 V
Zero output<±25 mV
Output impedance9 kΩ
Isolation100 MΩ
Operating temperature-23…+65 °C
Casestainless steel, O-ring
Mass30 g without cable

Part numbers

Show all part numbers (16)

1411-002-G-BT-NN, 1411-002-G-2S-NN, 1411-004-G-BT-NN, 1411-004-G-2S-NN, 1411-007-G-BT-NN, 1411-007-G-2S-NN, 1411-015-G-BT-NN, 1411-015-G-2S-NN, 1411-030-G-BT-NN, 1411-030-G-2S-NN, 1411-060-G-BT-NN, 1411-060-G-2S-NN, 1411-150-G-BT-NN, 1411-150-G-2S-NN, 1411-600-G-BT-NN, 1411-600-G-2S-NN

Request a price and lead time

Model 141 Linear Accelerometer with High-Level Output, ±2 to ±600 g. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What supply does the Model 141 need?

The BT version runs from 5 to 15 V DC and is calibrated at 10 V, while the 2S version runs from 10 to 28 V DC and is calibrated at 24 V. There is no reverse polarity protection, so a zener diode on the supply input is recommended.

Does the sensor measure static acceleration?

Yes, the DC output is proportional to acceleration from static up to about 3000 Hz, with a flat response to about 60% of the natural frequency.

How can the calibration be checked on site?

An external Rcal resistor is connected between the red calibration wire and the brown negative output wire, and the Rcal value is given on the calibration certificate.