Bureau of Mines Model 13 manual dew point analyser with chilled mirror

A portable chilled mirror instrument for measuring the dew point of gas, covering water and hydrocarbon dew points. It needs no electrical supply and no calibration, follows the standard ASTM D1142 method, and is used on natural gas pipelines, custody transfer stations and to check fixed analysers.

Measurement method
Chilled mirror, manual
Measured parameters
Dew point for water and hydrocarbons
Accuracy
±0.25°C (±0.5°F)
Dew point range
Depends on the certified thermometer selected

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The instrument measures the dew point temperature of natural gas directly in the pipeline, as well as industrial gases and heat treatment atmospheres at refineries, chemical and petrochemical plants. One unit covers both water dew point and hydrocarbon dew point, so separate instruments are not needed for the two. Typical locations include trunk gas pipelines, commercial metering stations, gas processing plants, condensate separation units and heat treating furnaces.

Measurement uses the chilled mirror method. Sample gas flows through the chamber while the mirror is cooled with a refrigerant such as liquefied propane or carbon dioxide. The operator acts as the detector, adjusting the cooling rate and reading the thermometer at the moment dew forms on the mirror. The recommended sample flow is about 5 SCFH, and the cooling rate should not exceed one to two degrees per minute. The measuring range depends on the certified thermometer selected.

Variants differ by permitted working pressure. Models 13-075 and 13-1175 are limited to 1000 psig (6.9 MPa), models 13-100 and 13-1200 are rated for a maximum working pressure of 3000 psig (20.7 MPa), and models 13-110 and 13-1210 work at pressures up to 5000 psig. Accuracy is ±0.25°C (±0.5°F). Sample inlet and outlet use 1/8-inch NPT threads, and the refrigerant is fed through 1/8-inch tubing. An optional gauge with an LCD display is available.

The instrument follows ASTM D1142 and is regarded as an industry reference for dew point measurement, so its readings are used to check fixed analysers. Conversion of dew point to water content is carried out with ASTM tables and GPA publication 2140. Measurements are also possible in sour natural gas, while oxygen service requires special cleaning of the unit.

No electrical supply is needed: connect the process gas and refrigerant and the instrument is ready, with no calibration performed. The kit is packed in a sealed case with a moulded insert measuring 457 x 178 x 355 mm, with a shipping weight of 11 kg. Optional items include a cooler, certified thermometers, a glycol filter, a stand, and a propane or CO2 cylinder.

Technical specifications

Measurement methodChilled mirror, manual
Measured parametersDew point for water and hydrocarbons
Accuracy±0.25°C (±0.5°F)
Dew point rangeDepends on the certified thermometer selected
Working pressureUp to 5000 psig (34.6 MPa)
Sample connection (in / out)1/8″ NPT
Coolant connection1/8″ tubing
Recommended sample flowAbout 5 SCFH
Electrical powerNot required
CalibrationNot required
Case (W x H x D)457 x 178 x 355 mm (18 x 7 x 14 in.)
Shipping weight11 kg (25 lb)
StandardsASTM D1142, GPA 2140

Part numbers

Show all part numbers (6)

13-100, 13-1200, 13-075, 13-1175, 13-110, 13-1210

Request a price and lead time

Bureau of Mines Model 13 manual dew point analyser with chilled mirror. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the dew point tester need a mains supply on site?

No, the instrument is fully manual. Only the process gas and refrigerant need to be connected for measurement.

Which version suits a gas line at 3000 psig?

Models 13-100 and 13-1200 are rated for a maximum working pressure of 3000 psig. For pressures up to 5000 psig the 13-110 and 13-1210 are designed.

Can it be used to check fixed moisture analysers?

Yes, the instrument meets ASTM D1142 and is used as a reference for checking fixed dew point analysers.