MIX 2XPRG 2-Channel Signal Isolator and Converter, 4-20 mA, 0-5 V, 1-5 V, 0-10 V Inputs
The MIX 2XPRG packs two isolated signal channels into a housing 25.4 mm wide. Each input is set by DIP switch to 4-20 mA, 0-5 V, 1-5 V or 0-10 V, and both outputs are 4-20 mA. Isolation reaches 1000 Vrms and the unit draws 12-42 V DC from the output loop.
- Type
- Multi-channel signal isolator and converter, 2-wire
- Number of channels
- 2
- Input (2XPRG)
- 4-20 mA, 0-5 V, 1-5 V or 0-10 V, DIP-switch selectable per channel
- Output (2X4-20mA)
- Two 4-20 mA channels
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The 2XPRG version of the MIX carries two independent channels in a housing 25.4 mm wide. A DIP switch on each channel selects the input type: 4-20 mA, 0-5 V, 1-5 V or 0-10 V. Each channel delivers a 4-20 mA output that connects straight to an indicator, recorder, DCS, PLC or SCADA system.
Isolation between inputs and outputs, and from channel to channel, is rated up to 1000 Vrms. It breaks ground loops and blocks motor noise and other electrical interference that cause false readings. The same unit can boost a signal when more instruments must share a heavily loaded loop, or split one primary measurement between several systems.
The MIX is a 2-wire device. Power of 12-42 V DC is taken from the output loop, normally supplied by the receiving device such as a DCS or PLC, so no separate supply is needed. This also cures the clash that occurs when a 4-wire transmitter and a DCS both try to power one process loop.
The metal case screens the unit against RFI/EMI. The universal DIN-style housing clips onto 32 mm G-type or 35 mm Top Hat rail and measures 114 x 102 x 25.4 mm. Accuracy is +/-0.1 %, and humidity 0-95 % non-condensing.
Approvals comprise UL, CSA for general locations, Non-Incendive Class I, Division 2, Groups A, B, C, D, CE conformity to EMC Directive 2014/30/EU (EN 61326) and Low Voltage Directive 2014/35/EU (EN 61010), and RoHS. Signal wiring should be shielded twisted pair, with the shield earthed at the unit. The unit has no HART pass-through and is not intended for SIS applications.
Technical specifications
| Type | Multi-channel signal isolator and converter, 2-wire |
|---|---|
| Number of channels | 2 |
| Input (2XPRG) | 4-20 mA, 0-5 V, 1-5 V or 0-10 V, DIP-switch selectable per channel |
| Output (2X4-20mA) | Two 4-20 mA channels |
| Power (12-42DC) | 12-42 V DC, drawn from the output loop |
| Isolation | Up to 1000 Vrms, input to output and channel to channel |
| Accuracy | +/-0.1 % |
| Humidity | 0-95 %, non-condensing |
| Housing | Universal DIN-style housing, 32 mm G-type and 35 mm Top Hat rail |
| Dimensions | 114 x 102 x 25.4 mm |
| HART / SIS | HART pass-through: no; for SIS use: no |
| Approvals | UL, CSA General Location, Non-Incendive/Div. 2, CE, RoHS |
Part numbers
Show all part numbers (1)
MIX/2XPRG/2X4-20mA/12-42DC
How it compares with similar models
| Parameter | MIX 2XPRG 2-Channel Signal Isolator and Converter, 4-20 mA, 0-5 V, 1-5 V, 0-10 V Inputs | MIT 2XPRG 2-Channel 4-Wire Signal Isolator and Converter, 20-125 VDC or 90-250 VAC Supply | FCT PRG/PRG/U/-TX Field-Configurable Signal Isolator, Converter and Repeater | SIX 1-5V/4-20mA 2-Wire Signal Isolator and Converter, 1500 Vrms Isolation |
|---|---|---|---|---|
| Type | Multi-channel signal isolator and converter, 2-wire | Multi-channel signal isolator and converter, 4-wire | Signal isolator, converter and repeater, 4-wire | Signal isolator, converter and repeater, 2-wire |
| Isolation | Up to 1000 Vrms, input to output and channel to channel | Up to 1000 Vrms input to output and channel to channel; 2500 Vrms between power and signals | 1000 Vrms between input, output and power; 500 Vac with -RF option | 1500 Vrms input to output; 500 Vrms with -RF option |
| Accuracy | +/-0.1 % | +/-0.1 % | +/-0.1 % of span | +/-0.1 % of span |
| Housing | Universal DIN-style housing, 32 mm G-type and 35 mm Top Hat rail | Universal DIN-style housing, 32 mm G-type and 35 mm Top Hat rail | Universal DIN-style housing, 32 mm G-type and 35 mm Top Hat rail | DIN-style housing, 32 mm G-type (EN50035) and 35 mm Top Hat (EN50022) rail |
| Dimensions | 114 x 102 x 25.4 mm | 114 x 111 x 25.4 mm | — | 127.5 x 80 x 25.4 mm |
| Approvals | UL, CSA General Location, Non-Incendive/Div. 2, CE, RoHS | UL, CSA General Location, Non-Incendive/Div. 2, CE, RoHS | CSA General Location | cULus Class I, Division 2, Groups A, B, C, D T4; CE; RoHS |
Request a price and lead time
MIX 2XPRG 2-Channel Signal Isolator and Converter, 4-20 mA, 0-5 V, 1-5 V, 0-10 V Inputs. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Does the MIX 2XPRG need a separate power supply?
No. It is a 2-wire unit powered at 12-42 V DC from the output loop, which the receiving device normally supplies.
Which input signals can each channel accept?
A DIP switch sets each channel to 4-20 mA, 0-5 V, 1-5 V or 0-10 V. Every channel outputs 4-20 mA.
Are the channels isolated from each other?
Yes. Isolation between inputs and outputs, and between channels, reaches 1000 Vrms.